Electrical equipment, wiring, motors, transformers and power systems can generate electromagnetic fields during operation. For technicians and facility personnel, measuring these fields can help identify sources and compare EMF levels at different locations.

 

The Tenmars TM-191A EMF Meter is a portable instrument suitable for general low-frequency electromagnetic field measurements around electrical equipment.

 

Why Measure EMF Around Electrical Equipment?

 

An EMF survey can help users understand where electromagnetic fields are present and how readings change according to distance and equipment operating conditions.

 

Typical applications include:

 

Electrical panels

 

Distribution boards

 

Motors

 

Transformers

 

Electrical cabinets

 

Production machinery

 

Office electrical equipment

 

Building electrical systems

 

Household electrical appliances

 

The objective is normally not simply to obtain one reading, but to build a clearer picture of the electromagnetic environment around the equipment.

 

Step 1: Identify the Equipment

 

Before taking measurements, determine what equipment you want to investigate.

 

Ask:

 

What type of equipment is operating?

 

Is it powered by mains electricity?

 

Where are the power cables located?

 

Are there motors or transformers inside?

 

Where do people normally stand or work?

 

This helps determine suitable measurement points.

 

Step 2: Establish a Reference Measurement

 

Start by taking a measurement away from the suspected EMF source.

 

This provides a reference reading that can later be compared with measurements closer to the equipment.

 

Avoid relying on only one measurement point.

 

Step 3: Move Toward the EMF Source

 

Take measurements at several locations around the equipment.

 

For example, readings can be taken:

 

Close to the equipment

 

At the normal operator position

 

At intermediate distances

 

Further away from the equipment

 

Comparing these readings can help identify how the measured field changes with distance.

 

Step 4: Check Different Sides of the Equipment

 

Electromagnetic fields may not be distributed equally around a machine or electrical installation.

 

Therefore, measurements can be taken at the:

 

Front

 

Rear

 

Left side

 

Right side

 

Operator position

 

Nearby occupied areas

 

This is particularly useful when checking larger industrial equipment.

 

Step 5: Compare Operating Conditions

 

Where appropriate and safe, measurements can also be compared under different operating conditions.

 

For example:

 

Equipment OFF → Equipment ON

 

or

 

Low load → Normal operating load

 

A significant change in the reading may help identify whether the equipment is contributing to the electromagnetic field detected at that location.

 

Never interfere with live electrical systems merely to perform an EMF measurement. Follow the site's electrical and workplace safety procedures.

 

Step 6: Record the Measurement Location

 

For professional surveys, recording only the EMF value may not provide enough information.

 

Consider documenting:

 

Equipment name

 

Measurement location

 

Distance from equipment

 

Operating condition

 

Measurement value

 

Date and time

 

This makes future comparisons more meaningful.

 

Distance Matters in EMF Measurement

 

One of the most useful ways to investigate an electromagnetic field source is to compare readings at different distances.

 

For example:

 

10 cm → 30 cm → 50 cm → 1 metre

 

The exact measurement points should depend on the application and site conditions.

 

This approach can provide much more useful information than taking a single reading directly beside the equipment.

 

Where Is the TM-191A Useful?

 

The Tenmars TM-191A can be considered for general EMF checking in:

 

Factories

 

Workshops

 

Commercial buildings

 

Offices

 

Electrical rooms

 

Laboratories

 

Residential properties

 

Maintenance departments

 

It is particularly useful when portability and straightforward field measurements are required.

 

Is TM-191A Suitable for Wi-Fi and 5G Testing?

 

Users should distinguish between low-frequency electromagnetic field measurement and radio-frequency (RF) measurement.

 

If the primary source is Wi-Fi, mobile communications, antennas or other RF equipment, an RF-capable meter designed for the relevant frequency range may be required.

 

Do not choose an EMF meter based only on the term "EMF".

 

The correct instrument depends on the source and frequency you intend to measure.

 

Choosing the Correct EMF Meter in Malaysia

 

Before purchasing an EMF meter, tell your supplier exactly what you intend to test.

 

For example:

 

"I need to measure EMF around an electrical transformer."

 

is much more useful than:

 

"I need an EMF meter."

 

Different EMF meters are designed for different applications.

 

MTM Precision can help Malaysian customers identify a suitable instrument based on the actual measurement requirement.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

15 Aug 2026