TASI TA622C Temperature Humidity Meter for Electronics Manufacturing Malaysia

Temperature and humidity can be important environmental parameters in electronics manufacturing, PCB assembly, electronic component storage, production rooms and QA/QC areas.


Electronic components, materials and manufacturing processes may be sensitive to environmental conditions. Temperature and relative humidity can also affect worker comfort, storage conditions, condensation risk and electrostatic control procedures.


The TASI TA622C Digital Thermo-Hygrometer measures temperature, relative humidity, dew point and wet bulb temperature and uses a separate measurement probe, making it useful for portable environmental inspection in electronics manufacturing facilities in Malaysia.


Why Monitor Temperature and Humidity in Electronics Manufacturing?


Environmental conditions inside a factory can vary from one location to another.


Possible causes include:


Air-conditioning distribution


Production equipment generating heat


Opening of doors


Outdoor humidity


Different production zones


Airflow restrictions


Storage conditions


Changes in occupancy


HVAC system performance


A fixed environmental sensor provides useful continuous information, but it measures conditions only at its installed location.


A portable temperature and humidity meter allows technicians to investigate individual production areas and compare environmental conditions between different locations.


What Can the TASI TA622C Measure?


The TASI TA622C provides four environmental measurements:


Temperature


Relative Humidity (RH)


Dew Point Temperature


Wet Bulb Temperature


The specified temperature measurement range is -40°C to 80°C.


Relative humidity measurement covers 0 to 100%RH.


Temperature accuracy is specified at ±0.5°C, while humidity accuracy is ±3%RH within 10–90%RH.


This allows technicians to evaluate both thermal and moisture conditions using one handheld instrument.


Temperature & Humidity Checks on the Production Floor


Electronics manufacturing facilities may contain several production and support areas.


The TA622C can be used to compare conditions around:


PCB assembly areas


Production lines


Component storage


QA/QC rooms


Testing areas


Packing areas


Equipment rooms


Air-conditioning outlets


Material storage areas


Measurements taken at several locations can help determine whether environmental conditions are reasonably consistent across the facility.


Separate Probe for Flexible Measurement


The TASI TA622C uses a separate temperature and humidity probe.


This configuration allows the sensing probe to be positioned close to a specific measurement point while the user keeps the display in a convenient viewing position.


It can be useful for checking:


Between production equipment


Near electronic component storage


Different heights


HVAC outlets


Restricted areas


Equipment cabinets


Specific work zones


This provides more flexibility than relying only on a sensor built directly into the meter body.


Relative Humidity and Electronics


Relative humidity can be an important parameter in electronics manufacturing and storage.


Environmental conditions may be relevant to:


Electronic components


PCB materials


Packaging


Moisture-sensitive materials


Storage areas


ESD control procedures


Production processes


However, acceptable humidity limits depend on the specific process, component, facility requirements and applicable standards.


The TA622C provides the measurement information, while the user should compare the readings against the appropriate internal or industry requirements.


Temperature & Humidity for ESD-Controlled Areas


Electrostatic discharge is an important consideration in many electronics manufacturing environments.


Humidity can influence electrostatic behaviour, but humidity measurement alone does not confirm whether an ESD control programme is compliant or effective.


The TASI TA622C can provide environmental temperature and RH measurements as part of a wider ESD control programme.


Other appropriate ESD testing instruments and procedures may still be required depending on the facility's requirements.


Dew Point Measurement


The TA622C also displays dew point temperature.


Dew point can be useful when investigating conditions associated with condensation.


This may be relevant around:


Cold equipment surfaces


Air-conditioning systems


Metal components


Storage areas


Temperature transition zones


Cooling equipment


When surface temperature approaches the dew point of the surrounding air, condensation may become more likely.


Having dew point information available directly on the meter can assist technicians during environmental troubleshooting.


Wet Bulb Temperature


The TASI TA622C provides wet bulb temperature in addition to standard temperature and relative humidity.


Wet bulb information can assist HVAC and facility personnel when evaluating air-conditioning and environmental conditions.


This means one instrument can provide several useful environmental parameters for production, maintenance and facility teams.


Data Recording for Factory Environmental Investigation


Factory environmental conditions may change during different production periods.


For example, temperature and humidity may change because of:


Equipment operation


Increased production activity


Shift changes


Door opening


HVAC cycling


Outdoor weather conditions


The TASI TA622C provides data recording capability and USB PC communication.


Recorded measurements can help investigate questions such as:


Does temperature rise during production?


Does humidity change between shifts?


Are some production areas consistently warmer?


Does opening a loading door affect RH?


Did environmental conditions improve after HVAC maintenance?


This provides more information than relying on a single instantaneous reading.


MAX / MIN / AVG Functions


The TA622C provides MAX / MIN / AVG functions.


These allow users to review maximum, minimum and average readings during a measurement period.


High and low limit alarm functions can also help users identify measurements that exceed predetermined limits.


Who Can Use the TASI TA622C?


The TA622C can be considered for:


Electronics manufacturers


PCB manufacturers


EMS companies


Semiconductor-related facilities


Electronic component warehouses


QA/QC departments


Production engineers


Facility management teams


Maintenance departments


HVAC contractors


The same instrument can also be used in laboratories, warehouses, server rooms and other controlled indoor environments.


TASI TA622C vs Basic Hygrometer for Factory Use


A basic digital hygrometer can display current temperature and humidity at one location.


The TA622C provides additional professional functions including:


Separate measurement probe


Temperature measurement


Relative humidity measurement


Dew point


Wet bulb temperature


MAX / MIN / AVG


High / low limit alarm


Data recording


USB PC communication


This makes the TA622C more suitable for technicians who need to investigate and compare environmental conditions at multiple locations.


TASI TA622C vs Fixed Factory Environmental Monitor


A fixed monitoring system is normally more suitable when the requirement is:


Continuous 24/7 monitoring


Multiple permanent sensors


Automatic alarms


Remote monitoring


Long-term records


The TASI TA622C is particularly useful for portable inspection and troubleshooting.


For example, when a fixed sensor indicates abnormal humidity, a technician can use the TA622C to investigate different locations around the production floor.


The two types of instruments can therefore complement each other.


Is TASI TA622C Suitable for Electronics Manufacturing?


Yes.


Its combination of temperature, relative humidity, dew point, wet bulb, separate probe and data recording makes the TA622C useful for portable environmental inspection in electronics manufacturing facilities.


For specialised ESD, cleanroom or regulated process monitoring, additional instruments and appropriate procedures may still be required.


Frequently Asked Questions


Can TASI TA622C be used in an electronics factory?

Yes. It can be used for portable temperature and humidity inspection in production, storage and QA/QC areas.


Can TA622C measure humidity in PCB assembly areas?

Yes. Its specified relative humidity measurement range is 0 to 100%RH.


Is TA622C an ESD tester?

No. It is a temperature and humidity measuring instrument. It can provide environmental RH information as part of an ESD control programme, but it does not replace dedicated ESD testing equipment.


Does TA622C measure dew point?

Yes. Dew point temperature is available directly on the instrument.


Can TA622C record measurements?

Yes. It provides data recording functionality and supports USB PC communication.


Why is the separate probe useful?

It allows technicians to position the sensor near specific production areas, equipment, storage locations or HVAC outlets while keeping the meter display visible.


Looking for an Electronics Manufacturing Temperature & Humidity Meter in Malaysia?


MTM Precision supplies professional testing and measurement instruments for electronics manufacturing, PCB assembly, QA/QC, laboratories, warehouses, HVAC, facility management and industrial environmental monitoring applications in Malaysia.


If you are looking for the TASI TA622C Digital Thermo-Hygrometer or need help selecting a suitable temperature and humidity measurement instrument for your factory, contact MTM Precision.


Contact MTM Precision


MTM Precision Sdn Bhd


No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


Website: www.mtmpre.com.my

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com



25 Aug 2026