Coating Thickness Gauge for Metal Fabrication Steel, Aluminium & Galvanized QC Malaysia

Metal fabrication does not always end when cutting, bending and welding are completed. Many fabricated components also require surface finishing such as painting, powder coating or galvanizing. That creates another quality-control requirement: Is the finished coating thickness within the required specification? A portable coating thickness gauge allows fabricators to perform non-destructive checks on suitable coatings without cutting or damaging the finished component. For fabrication companies handling different metals, the TASI TA521A and TA522A Coating Thickness Gauges provide Fe, NFe and Fe+Zn measurement capabilities in one portable instrument. Where Is Coating Thickness Measurement Used in Fabrication? Potential applications include: Steel fabrication Sheet metal fabrication Aluminium fabrication Structural steel Machinery frames Electrical enclosures Control panels Steel cabinets Equipment housings Racking Handrails Platforms Fabricated brackets Galvanized components Powder-coated products For these products, coating thickness may be checked during production or before delivery. Why Fabricators Should Measure Coating Thickness Fabricators may outsource painting, powder coating or galvanizing to another supplier. Others perform finishing internally. Either way, relying only on visual inspection creates a limitation. A coating can look acceptable while its thickness differs from the required specification. A thickness gauge provides actual measurement data that can support: Incoming inspection Production QC Subcontractor inspection Final inspection Customer documentation Process improvement Steel Fabrication Steel is one of the most common materials used by fabricators. For a typical coated steel component: Paint / Powder Coating → Steel a suitable coating thickness gauge uses the magnetic induction principle. This is commonly identified as: Fe measurement Potential products include: Steel frames Machinery bases Cabinets Structural components Racking Brackets Platforms Equipment supports Both the TASI TA521A and TA522A support Fe measurement. Aluminium Fabrication Aluminium requires a different measurement principle. For suitable non-conductive coatings over compatible conductive aluminium: Paint / Powder Coating → Aluminium the gauge uses: NFe / Eddy Current Measurement This is why an Fe-only coating thickness gauge may not be sufficient for a fabrication company working with both steel and aluminium. The TA521A and TA522A support both Fe and NFe. Galvanized Fabrication Galvanized steel introduces another layer: Steel → Zinc The TASI TA521A and TA522A also provide Fe+Zn measurement capability. The specified Fe+Zn range is: 3500 μm This gives the series an additional application for appropriate galvanized steel measurement. However, always understand the complete coating structure. Painted Galvanized Steel A fabricated component may be: Steel → Zinc → Paint or: Steel → Zinc → Powder Coating This is more complex than ordinary paint directly over bare steel. Before measuring, determine what the inspection requirement actually asks for: Zinc thickness? Paint thickness? Total coating system? Do not assume one displayed reading automatically separates every individual layer. For multilayer systems, the measurement requirement should be confirmed carefully. TASI TA522A for Fabrication QC The TASI TA522A provides: General measuring range: 02000 μm Stated accuracy: ±(3% + 1 μm) Resolution below 100 μm: 0.1 μm Fe magnetic induction measurement NFe eddy current measurement Automatic substrate recognition Manual measurement mode selection Fe+Zn measurement capability Fe+Zn range: 3500 μm Zero calibration μm / mm / mil units 2 readings per second 180° screen rotation For fabrication companies handling multiple materials, this combination provides useful flexibility. Why Dual Fe/NFe Is Useful in a Fabrication Shop Consider a fabricator producing three jobs: Job A → Powder-coated steel cabinet Job B → Painted aluminium enclosure Job C → Galvanized steel bracket A basic Fe-only coating gauge cannot necessarily cover all three requirements. A multi-application instrument reduces the need to keep different basic gauges for suitable Fe and NFe coating measurements. Incoming Inspection Fabricators often purchase finished or semi-finished components from subcontractors. For example: Fabricator → Sends Parts for Powder Coating → Parts Return → Incoming QC Instead of checking only colour and appearance, the fabricator can include coating thickness measurement in the receiving inspection. A basic workflow is: Subcontractor Delivery ↓ Visual Inspection ↓ Coating Thickness Measurement ↓ Compare With Requirement ↓ Accept / Investigate This can help identify problems before the parts are assembled or delivered to the customer. In-Process QC If coating is performed internally, measurements can be incorporated into production. For example: Coating Process ↓ Curing ↓ Sample DFT Measurement ↓ Review Result ↓ Continue Production / Investigate This provides feedback before an entire batch is completed. Final Inspection Coating thickness can also be included in final QC before shipment. For fabricated products, final inspection may already include: Dimensions Welding Assembly Appearance Function Packaging Where coating thickness is specified, add: DFT / Coating Thickness to the final inspection checklist. Subcontractor Quality Control Coating measurement is especially valuable when surface finishing is outsourced. Instead of telling the subcontractor: “The coating seems thin.” you can provide: Part number + measurement location + actual reading + required specification Objective measurement data can improve discussions about: Rework Rejection Corrective action Process improvement Standardize Measurement Locations Fabricated products often have complex shapes. For repetitive components, define standard measurement locations. For example, on an electrical enclosure: Point A Door Point B Left panel Point C Right panel Point D Top Point E Rear Using the same measurement points helps compare: Different batches Different subcontractors Different operators Different production dates Be Careful Around Welds and Edges Fabricated products commonly contain: Welds Corners Edges Narrow sections Curved surfaces These areas may present different coating and measurement conditions compared with large flat surfaces. For formal QC, follow the applicable measurement procedure and instrument requirements. Do not assume every location on a fabricated component provides identical measurement conditions. Curved Fabricated Components Examples include: Pipes Round frames Cylindrical components Curved brackets Curvature an influence measurement conditions. If small-diameter components are a major part of your work, confirm gauge suitability for the actual geometry. Coating Thickness vs Metal Thickness Fabricators also need to distinguish between two different measurements. Coating Thickness Example: How thick is the powder coating on this steel plate? Use: Coating Thickness Gauge Material Thickness Example: How thick is the steel plate itself? Depending on the application, use an appropriate dimensional or ultrasonic thickness measurement method. The TA521A and TA522A are coating thickness gauges, not conventional ultrasonic wall thickness gauges. TA521A vs TA522A for Fabricators Both models provide: Fe measurement NFe measurement Automatic substrate recognition Fe+Zn capability 02000 μm general range ±(3% + 1 μm) stated accuracy Zero calibration The TA522A additionally provides manual measurement mode selection. Therefore: TA521A → General fabrication checking / value option TA522A → Regular professional fabrication QC For a fabrication company taking measurements frequently, we generally prefer the TA522A. Do Fabricators Need Calibration? That depends on how the measurements are used. Calibration documentation may become important when the gauge is used for: ISO-controlled QC Customer acceptance Project inspection Contractual measurement Third-party inspection Do not confuse formal calibration with routine zero adjustment. Check the actual customer and quality-system requirements. Who Should Consider a Coating Thickness Gauge? Potential users include: Sheet metal fabricators Structural steel fabricators Aluminium fabricators Machinery manufacturers Electrical enclosure manufacturers Control panel manufacturers Racking manufacturers Engineering workshops Powder coating companies Metal finishing companies Factory QA/QC For these companies, a coating thickness gauge can become a relatively simple tool with applications across multiple jobs. Common Fabrication QC Mistakes Checking Only Appearance A coating can look good without proving its thickness. Buying an Fe-Only Gauge When Aluminium Is Also Used Consider a dual Fe/NFe model. Ignoring Galvanized Steel Galvanized applications require additional consideration. Measuring Random Locations Standard measurement points improve consistency. Confusing Coating Thickness With Plate Thickness These require different measurement technologies. Waiting Until Customer Rejection Internal QC before delivery can identify problems earlier. FAQ What coating thickness gauge is suitable for steel fabrication? For suitable coatings over ferrous steel, a magnetic induction coating thickness gauge can be used. Can TASI TA522A measure powder coating on steel? Yes, for suitable coating/substrate combinations within its measurement specifications. Can TA522A measure aluminium? It supports NFe eddy current measurement for suitable coatings over compatible conductive non-ferrous substrates such as aluminium. Can it measure galvanized steel? The TA522A includes Fe+Zn measurement capability with a specified Fe+Zn range of 3500 μm. The exact layer structure and measurement requirement should still be confirmed. Can it measure steel plate thickness? TA522A is designed for coating thickness measurement. It is not a conventional ultrasonic gauge for full steel plate or wall thickness measurement. Which is better for a fabrication company, TA521A or TA522A? For occasional straightforward measurements, TA521A can be considered. For regular professional QC, we generally prefer TA522A because it adds manual measurement mode selection. Looking for a Coating Thickness Gauge for Metal Fabrication in Malaysia? Tell MTM Precision what your fabrication company actually works with: Steel? Aluminium? Galvanized steel? Paint? Powder coating? Also tell us the approximate coating thickness and whether the gauge will be used for general checking, factory QC or customer inspection. We can help determine the appropriate measurement approach. For general multi-material coating inspection, the TASI TA521A and TA522A provide Fe/NFe and Fe+Zn capabilities in one portable instrument. For regular fabrication QC, the TA522A is our preferred model when its additional manual mode control is useful. Contact MTM Precision MTM Precision Sdn Bhd No. 29-1 & 29-2, Jalan Bandar 18 Pusat Bandar Puchong 47160 Puchong, Selangor, Malaysia Website: www.mtmpre.com.my WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com

26 Aug 2026