Where to Measure Vibration on a Motor DE, NDE, Horizontal, Vertical & Axial Malaysia

Where to Measure Vibration on a Motor – DE, NDE, Horizontal, Vertical & Axial Malaysia Quick Answer For routine electric motor vibration monitoring, measurements are commonly taken on solid locations close to the motor bearing housings. Typical motor vibration measurement points include: Drive End (DE) – Horizontal Drive End (DE) – Vertical Drive End (DE) – Axial Non-Drive End (NDE) – Horizontal Non-Drive End (NDE) – Vertical Non-Drive End (NDE) – Axial where appropriate The most important rule is repeatability. If you want to trend motor vibration, measure at the same point, same direction, same vibration parameter and similar operating condition each time. What Are DE and NDE on an Electric Motor? Two terms appear frequently in motor vibration work: DE – Drive End NDE – Non-Drive End Understanding these locations makes vibration records much easier to organise. What Is the Drive End? The Drive End (DE) is generally the end of the motor where power is transmitted to the driven equipment. Depending on the installation, the motor may drive equipment through: Coupling Pulley Belt Gear arrangement Direct connection For example: Motor → Coupling → Pump The motor side closest to the coupling and pump is normally the drive end. What Is the Non-Drive End? The Non-Drive End (NDE) is the opposite end of the motor. It is sometimes also called the opposite drive end. A simple way to visualise the motor is: NDE [ MOTOR ] DE → Coupling → Pump Both ends can provide useful vibration information. Why Measure Near the Bearings? Bearings support the motor shaft. Mechanical vibration from the rotating assembly is transmitted through the bearing structure into the motor housing. For this reason, solid locations associated with the bearing housings are commonly selected for vibration measurement. The objective is to obtain a stable mechanical measurement rather than measure a flexible cover, thin guard or unrelated surface. Where Should the Sensor Be Placed? The sensor should normally be placed on a solid, repeatable machine surface appropriate to the measurement. Avoid choosing a location simply because it is easiest to reach. Poor measurement locations can include: Loose covers Thin sheet-metal guards Flexible panels Labels Unstable surfaces Locations that cannot be repeated consistently Where possible, document or mark the measurement point so another technician can return to the same position. What Are Horizontal, Vertical and Axial Measurements? Motor vibration can occur in different directions. This is why maintenance programmes may measure more than one orientation. Horizontal Vibration Horizontal vibration is measured in a radial direction horizontally relative to the motor shaft. It is commonly included in routine vibration routes. A record might say: MTR-01 DE-H = 2.1 mm/s RMS where: DE-H = Drive End Horizontal Vertical Vibration Vertical vibration is another radial measurement, taken vertically relative to the shaft. For example: MTR-01 DE-V = 1.8 mm/s RMS where: DE-V = Drive End Vertical Axial Vibration Axial vibration is measured approximately parallel to the shaft axis. For example: MTR-01 DE-A = 1.4 mm/s RMS where: DE-A = Drive End Axial Axial measurements can provide additional information in some machinery investigations. Radial vs Axial Vibration Horizontal and vertical measurements are generally considered radial measurements because they are taken across the shaft axis. Axial measurement is taken along the shaft direction. Therefore: Horizontal → Radial Vertical → Radial Axial → Along the shaft This distinction is useful when organising vibration inspection data. Do I Need All Six Motor Measurement Points? Not necessarily. A comprehensive route may include: Motor LocationDirectionDrive EndHorizontalDrive EndVerticalDrive EndAxialNon-Drive EndHorizontalNon-Drive EndVerticalNon-Drive EndAxial But the appropriate number of measurement points depends on: Machine criticality Motor accessibility Maintenance objective Equipment design Available time Monitoring programme For basic routine screening, a company may establish fewer repeatable points. For more detailed condition monitoring, additional measurements may be appropriate. Which Point Should I Measure First? If you are starting a basic vibration programme, the priority is not finding one magical measurement point. The priority is establishing a repeatable system. For example, you may establish: DE Horizontal and: NDE Horizontal as initial routine measurement locations. If more detailed information is required, add vertical and axial measurements according to the maintenance procedure. The exact route should suit the machine and maintenance objective. Example Motor Measurement Layout Consider a motor connected to a centrifugal pump. The equipment arrangement is: NDE [ MOTOR ] DE → Coupling → PUMP The vibration route might be: Motor NDE-H Motor NDE-V Motor DE-H Motor DE-V Motor DE-A Pump DE-H Pump DE-V Pump NDE-H Pump NDE-V Now the technician has a repeatable map for future inspections. Why Direction Matters Suppose today's reading is: DE Horizontal = 2.0 mm/s Next month the technician measures: DE Vertical = 2.8 mm/s and concludes: “Vibration increased from 2.0 to 2.8 mm/s.” That conclusion may be misleading. The two readings were taken in different directions. For trending, compare: DE Horizontal today with: DE Horizontal previously and: DE Vertical today with: DE Vertical previously. Why Exact Measurement Location Matters Even measurements in the same direction can change if the sensor position changes significantly. For example: DE Horizontal – Point A should ideally be compared with future readings from: DE Horizontal – Point A not an arbitrary location elsewhere on the motor. This is why good vibration routes define both: Location + Direction A Simple Naming System Maintenance teams can use short codes. Motor Measurement Codes DE-H = Drive End Horizontal DE-V = Drive End Vertical DE-A = Drive End Axial NDE-H = Non-Drive End Horizontal NDE-V = Non-Drive End Vertical NDE-A = Non-Drive End Axial This makes spreadsheets and maintenance records easier to manage. Example Vibration Record DateMachinePointParameterReading26 Aug 2026MTR-01DE-HVelocity RMS1.8 mm/s26 Aug 2026MTR-01DE-VVelocity RMS1.6 mm/s26 Aug 2026MTR-01DE-AVelocity RMS1.3 mm/s26 Aug 2026MTR-01NDE-HVelocity RMS1.7 mm/s26 Aug 2026MTR-01NDE-VVelocity RMS1.5 mm/s These readings are examples of a recording format only. They are not universal vibration limits. Trending the Same Measurement Point Suppose the DE-H measurement produces: MonthDE-H VelocityJanuary1.7 mm/sFebruary1.8 mm/sMarch1.7 mm/sApril1.9 mm/sMay2.3 mm/sJune3.0 mm/sJuly3.8 mm/s Now the maintenance team has a meaningful trend. The important observation is: DE-H vibration has progressively increased from approximately 1.8 mm/s to 3.8 mm/s. That gives technicians a reason to investigate further. Should I Measure the Motor or the Driven Machine? Ideally, do not think of them as completely separate when investigating a machine train. For example: Motor → Coupling → Pump Vibration can be influenced by the: Motor Coupling Pump Alignment Foundation Operating condition If only the motor is measured, part of the mechanical picture may be missed. Where practical, establish points on both the driver and driven equipment. Pump and Motor Example Suppose: Motor DE-H = 4.2 mm/s while: Motor NDE-H = 1.9 mm/s and the pump-side vibration is also elevated near the coupling. This pattern may justify closer investigation around the drive-end, coupling, alignment and pump area. However, these readings alone should not be used to declare a specific fault without further diagnosis. Does Horizontal Vibration Mean Imbalance? Not automatically. Different mechanical faults can influence vibration in different directions, but an overall handheld reading alone should not be used as a definitive fault diagnosis. Higher horizontal vibration can occur for several reasons. The technician should consider: Machine construction Mounting Speed Operating condition Other measurement points Historical trend Additional diagnostic information Does Axial Vibration Mean Misalignment? Not automatically. Axial vibration can be relevant during investigations involving alignment and other mechanical conditions. However: High axial vibration ≠ automatic proof of misalignment. A proper diagnosis may require additional measurements and mechanical inspection. Where Should I Not Measure? Avoid poor measurement surfaces where possible. Examples include: Thin Fan Covers A flexible cover can vibrate differently from the bearing housing. Belt Guards A belt guard is not necessarily representative of the actual machine bearing vibration. Loose Panels Loose structures can produce their own vibration. Unstable Sensor Positions If the probe or sensor slips during measurement, repeatability suffers. Different Locations Every Inspection This destroys much of the value of trending. Sensor Contact Matters Different vibration meters use different sensor arrangements. Some instruments use: Integrated contact probe External vibration sensor Magnetic sensor arrangement Regardless of design, consistent sensor contact is important. Follow the instrument manufacturer's instructions for the measurement method being used. Should I Use a Magnetic Base? Where the instrument supports it and the machine surface is suitable, a magnetic sensor mounting can provide repeatable contact. However, not every surface or measurement location is suitable for magnetic mounting. The instrument and sensor configuration should determine the correct approach. Which Vibration Parameter Should Be Measured? For routine overall motor vibration monitoring, vibration velocity in mm/s is commonly useful. For more detailed work, technicians may also measure: Acceleration and: Displacement The required parameter depends on the maintenance objective. Which Vibration Meter Is Suitable? MTM Precision currently carries six ready-stock vibration meters. LANDTEK VM-6310 The LANDTEK VM-6310 is particularly relevant for routine vibration velocity measurement. It is suitable for customers mainly performing overall vibration checks on: Motors Pumps Fans Blowers Compressors General rotating machinery LANDTEK VM-6360 The LANDTEK VM-6360 provides: Acceleration Velocity Displacement It is a stronger choice when broader vibration measurement capability is required. SMART SENSOR AR63B The SMART SENSOR AR63B also provides acceleration, velocity and displacement measurement. It is particularly relevant when acceleration and higher-frequency measurement capability are important. WINTACT WT63A / WT63B The WINTACT WT63A and WT63B provide additional portable choices for routine vibration inspection. BENETECH GM63B The BENETECH GM63B uses an external vibration sensor configuration, which can be useful where users prefer separating the sensor from the handheld display. Quick Selection Guide RequirementSuggested DirectionBasic motor vibration routeVelocity measurementRoutine DE / NDE monitoringLANDTEK VM-6310Acceleration + Velocity + DisplacementLANDTEK VM-6360 / SMART SENSOR AR63BBearing-focused workConsider acceleration + frequency rangeEconomical portable choiceWINTACT WT63A / WT63BExternal sensor preferenceBENETECH GM63B Common Motor Measurement Point Mistakes Measuring the Belt Guard The guard may have its own vibration characteristics. Recording “Motor = 3.2 mm/s” This does not identify where the reading was taken. A better record is: MTR-01 / DE-H / Velocity RMS / 3.2 mm/s Mixing Horizontal and Vertical Readings Compare like with like. Changing Sensor Position Small changes can reduce repeatability. Forgetting the Operating Condition Motor speed and load can affect vibration. Measuring Only After a Problem Appears Baseline readings are most useful when collected while the motor is operating normally. FAQ – Motor Vibration Measurement Points Where is the best place to measure vibration on a motor? Solid, repeatable locations associated with the motor bearing housings are commonly used. What does DE mean? DE means Drive End, generally the side of the motor transmitting power to the driven equipment. What does NDE mean? NDE means Non-Drive End, the opposite end of the motor. What is DE-H? DE-H means Drive End Horizontal. Should I measure horizontal and vertical vibration? Both directions can provide useful vibration information. The appropriate measurement route depends on the machine and maintenance objective. What is axial vibration? Axial vibration is measured approximately parallel to the motor shaft. Should I measure vibration on the motor cover? A solid location associated with the bearing housing is generally more useful than a flexible cover or guard. Is high axial vibration always misalignment? No. Axial vibration can be relevant during a misalignment investigation, but it does not automatically prove misalignment. What vibration parameter should I use? For routine overall motor condition monitoring, vibration velocity in mm/s is commonly useful. Where can I buy a vibration meter in Malaysia? MTM Precision supplies ready-stock vibration meters from LANDTEK, WINTACT, BENETECH and SMART SENSOR for motor and industrial machinery maintenance applications in Malaysia. Need Help Setting Up Your Vibration Measurement Points? Tell MTM Precision what equipment you are monitoring: Motor / Pump / Fan / Blower / Compressor / Generator / HVAC Equipment and whether your objective is: Routine inspection / Trending / Preventive maintenance / Bearing investigation We can help you select a suitable vibration meter according to your measurement requirements. Contact MTM Precision MTM Precision Sdn Bhd No. 29-1 & 29-2, Jalan Bandar 18 Pusat Bandar Puchong 47160 Puchong, Selangor, Malaysia Website: www.mtmpre.com.my WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Contact MTM Precision for vibration meter selection, comparison, quotation and product availability in Malaysia. Published Date: 26 August 2026

26 Aug 2026