How to Create a Vibration Monitoring Checklist for Motors, Pumps & Fans Malaysia
How to Create a Vibration Monitoring Checklist for Motors, Pumps & Fans Malaysia
Quick Answer
A practical vibration monitoring checklist should record more than just the vibration number.
For every machine, record:
-
Asset ID
-
Machine type
-
Date and time
-
Operating condition
-
Speed or RPM where relevant
-
Measurement location
-
Measurement direction
-
Vibration parameter
-
Unit
-
Current reading
-
Previous reading
-
Trend or change
-
Visual or audible observations
-
Corrective action required
For routine overall machinery monitoring, vibration velocity in mm/s RMS is commonly useful.
The key to a successful vibration programme is:
Measure consistently → Record consistently → Trend consistently → Investigate meaningful changes.
Why Use a Vibration Monitoring Checklist?
Buying a vibration meter is easy.
Building useful vibration history requires discipline.
Without a checklist, technicians may:
-
Measure different locations
-
Forget the measurement direction
-
Use different parameters
-
Forget machine speed
-
Record only the vibration number
-
Lose previous readings
-
Miss developing trends
A simple checklist creates a repeatable procedure.
What Is the Purpose of Vibration Monitoring?
Routine vibration monitoring helps maintenance personnel identify changes in rotating machinery.
Common equipment includes:
-
Electric motors
-
Pumps
-
Fans
-
Blowers
-
Compressors
-
Generators
-
Cooling towers
-
HVAC equipment
-
Production machinery
The objective is not necessarily to diagnose every fault immediately.
The first objective is often:
Identify which machine is changing and deserves attention.
Step 1 – Create an Asset List
Start by listing the rotating equipment you want to monitor.
For example:
| Asset ID | Equipment | Location |
|---|---|---|
| MTR-01 | Pump Motor | Pump Room |
| P-01 | Centrifugal Pump | Pump Room |
| FAN-01 | Exhaust Fan | Production |
| AHU-01 | AHU Fan Motor | Level 2 |
| COMP-01 | Air Compressor | Utility Room |
Every machine should have a clear identity.
Do not simply write:
“Motor”
because a factory may have dozens or hundreds of motors.
Step 2 – Rank Machine Criticality
Not every machine requires the same attention.
A simple system is:
A – Critical
Failure may cause:
-
Production shutdown
-
Safety issue
-
Major process interruption
-
Significant repair cost
B – Important
Failure affects operation but can be managed temporarily.
C – Non-Critical
Failure has relatively limited operational impact or standby equipment is available.
This ranking can help determine vibration monitoring frequency.
Step 3 – Establish Measurement Points
Do not allow technicians to choose a random location every inspection.
For a motor, typical points may include:
DE-H – Drive End Horizontal
DE-V – Drive End Vertical
DE-A – Drive End Axial
NDE-H – Non-Drive End Horizontal
NDE-V – Non-Drive End Vertical
NDE-A – Non-Drive End Axial
The actual points used should suit the machine and maintenance objective.
Step 4 – Mark the Measurement Locations
Where practical, clearly identify the repeatable sensor locations.
This can be done through:
-
Maintenance drawings
-
Machine photographs
-
Numbered points
-
Equipment records
-
Physical marking where appropriate
The objective is simple:
Technician A and Technician B should measure the same location.
Step 5 – Select the Vibration Parameter
For routine overall rotating machinery monitoring, vibration velocity is commonly useful.
A typical record may therefore be:
Velocity RMS: 2.4 mm/s
Some applications may also require:
-
Acceleration
-
Displacement
Do not change parameters randomly between inspections.
Step 6 – Record the Unit
Never record only:
2.4
Is that:
2.4 mm/s?
2.4 m/s²?
2.4 g?
A proper vibration record should always include the measurement unit.
Step 7 – Record Machine Speed
Where practical, record machine speed.
For example:
1,480 RPM
This becomes particularly important for:
-
Variable-speed motors
-
VFD-driven fans
-
Pumps with changing operating speed
-
Production machinery operating at different speeds
Vibration at significantly different speeds may not be directly comparable.
Step 8 – Record Operating Condition
Also consider whether the machine is operating at:
-
Normal load
-
Full load
-
Reduced load
-
No load
-
Different process condition
For example:
Pump P-01 / 2.3 mm/s / Normal Operating Load
is more informative than:
Pump P-01 / 2.3 mm/s
Step 9 – Measure Consistently
For useful trending, aim for:
Same machine
Same measurement point
Same direction
Same parameter
Same unit
Comparable operating condition
This is one of the most important rules in vibration monitoring.
Step 10 – Record the Current Reading
A complete entry might look like:
Asset: MTR-01
Point: DE-H
Speed: 1,480 RPM
Parameter: Velocity RMS
Reading: 1.8 mm/s
Condition: Normal Load
Date: 26 August 2026
Now the reading has context.
Step 11 – Compare with Previous Measurements
Do not stop after recording the current value.
Compare it with the historical trend.
For example:
| Month | MTR-01 DE-H |
|---|---|
| January | 1.4 mm/s |
| February | 1.5 mm/s |
| March | 1.5 mm/s |
| April | 1.7 mm/s |
| May | 2.0 mm/s |
| June | 2.5 mm/s |
| July | 3.1 mm/s |
This immediately shows a developing change.
Step 12 – Record Other Observations
Vibration should not always be considered in isolation.
During the inspection, technicians may also notice:
-
Unusual noise
-
Increased temperature
-
Oil leakage
-
Loose bolts
-
Damaged mounting
-
Coupling condition
-
Belt condition
-
Dust or material buildup
-
Abnormal machine movement
Record relevant observations.
Example Motor Vibration Checklist
| Item | Check |
|---|---|
| Asset ID confirmed | ☐ |
| Motor operating normally | ☐ |
| RPM recorded | ☐ |
| DE-H measured | ☐ |
| DE-V measured | ☐ |
| DE-A measured if required | ☐ |
| NDE-H measured | ☐ |
| NDE-V measured | ☐ |
| Unit recorded | ☐ |
| Previous reading compared | ☐ |
| Abnormal noise checked | ☐ |
| Mounting visually checked | ☐ |
| Follow-up required | ☐ |
The exact checklist should be adapted to the machine.
Motor Vibration Record Example
| Point | Previous | Current | Change |
|---|---|---|---|
| DE-H | 1.8 mm/s | 2.0 mm/s | +0.2 |
| DE-V | 1.6 mm/s | 1.7 mm/s | +0.1 |
| NDE-H | 1.7 mm/s | 1.8 mm/s | +0.1 |
| NDE-V | 1.5 mm/s | 1.5 mm/s | 0 |
The readings appear relatively stable.
Continue trending according to the maintenance schedule.
Example Pump Vibration Checklist
A pump system should often be considered as a machine train:
Motor → Coupling → Pump
Possible checklist items include:
-
Motor DE vibration
-
Motor NDE vibration
-
Pump DE vibration
-
Pump NDE vibration
-
Coupling area observation
-
Pump noise
-
Leakage
-
Mounting
-
Operating flow condition
-
Speed
-
Historical trend
Do not look only at the motor if the driven pump may be contributing to the vibration.
Pump Record Example
| Location | Previous | Current |
|---|---|---|
| Motor DE-H | 1.9 mm/s | 2.0 mm/s |
| Motor NDE-H | 1.6 mm/s | 1.7 mm/s |
| Pump DE-H | 2.1 mm/s | 3.4 mm/s |
| Pump NDE-H | 2.0 mm/s | 3.2 mm/s |
In this example, the largest change is occurring on the pump side.
That does not automatically identify the fault.
But it tells the maintenance team where further investigation should be concentrated.
Example Fan Vibration Checklist
Industrial fan vibration monitoring may include:
-
Motor vibration
-
Fan bearing vibration
-
Drive arrangement
-
Belt condition
-
Pulley condition
-
Fan buildup
-
Mounting
-
Unusual noise
-
Operating speed
-
Vibration trend
Fan imbalance can develop when material accumulates unevenly on the fan.
However, elevated vibration should not automatically be labelled as imbalance without investigation.
Fan Record Example
Suppose:
January → 1.8 mm/s
February → 1.9 mm/s
March → 2.0 mm/s
April → 2.9 mm/s
May → 4.0 mm/s
This trend deserves attention.
Maintenance personnel may inspect:
-
Fan wheel
-
Material buildup
-
Bearings
-
Belt drive
-
Mounting
-
Motor
-
Structural condition
Example Blower Checklist
For a blower, record:
-
Motor DE
-
Motor NDE
-
Blower bearing points
-
Speed
-
Load
-
Noise
-
Temperature observations
-
Mounting
-
Vibration trend
The exact measurement points depend on the blower design.
Example Compressor Checklist
Compressors require additional care because different compressor types can have very different vibration behaviour.
Record:
-
Compressor type
-
Operating load
-
Speed
-
Measurement point
-
Vibration parameter
-
Historical trend
-
Unusual noise
-
Temperature observations
-
Maintenance history
Do not blindly apply a generic motor checklist to every compressor.
Example Cooling Tower Checklist
A cooling tower inspection may include:
Motor
Gearbox
Drive shaft
Fan
Bearings
Possible vibration points should be defined according to the actual equipment configuration.
Cooling tower maintenance personnel should also observe:
-
Mechanical looseness
-
Fan condition
-
Gearbox condition
-
Mounting
-
Abnormal noise
Daily, Weekly, Monthly or Quarterly?
The checklist can include a field for:
Inspection Frequency
For example:
| Criticality | Example Approach |
|---|---|
| A – Critical | More frequent monitoring |
| B – Important | Monthly starting point |
| C – Lower Criticality | Longer interval where appropriate |
| Abnormal Trend | Increase frequency + investigate |
The correct interval depends on the facility and machine risk.
Add a Trend Status
Instead of only recording numbers, add a simple status.
For example:
Stable
Increasing
Sudden Change
After Repair
Needs Investigation
This helps maintenance supervisors quickly review many machines.
Example Vibration Monitoring Sheet
| Date | Asset | Point | RPM | Velocity RMS | Trend | Action |
|---|---|---|---|---|---|---|
| 26 Aug 2026 | MTR-01 | DE-H | 1480 | 1.8 mm/s | Stable | Continue |
| 26 Aug 2026 | P-01 | DE-H | 1480 | 3.2 mm/s | Increasing | Inspect |
| 26 Aug 2026 | FAN-01 | DE-H | 1450 | 1.9 mm/s | Stable | Continue |
| 26 Aug 2026 | BLW-01 | DE-H | 2900 | 4.1 mm/s | Sudden Change | Recheck |
This type of sheet can be maintained in:
-
Excel
-
Maintenance software
-
CMMS
-
Digital inspection system
-
Paper maintenance record
The software is less important than consistency of the data.
Should You Put a Green / Yellow / Red Status?
You can, but the criteria must be defined properly.
Do not create arbitrary rules such as:
Below 2 mm/s = Green
2–4 mm/s = Yellow
Above 4 mm/s = Red
and apply them to every machine.
Evaluation should consider:
-
Machine category
-
Applicable standard
-
Manufacturer criteria
-
Historical baseline
-
Operating condition
Where formal vibration evaluation is required, use the appropriate criteria such as the relevant parts of ISO 20816.
Add a Baseline Column
One useful improvement is adding:
Baseline
For example:
| Asset | Point | Baseline | Current |
|---|---|---|---|
| MTR-01 | DE-H | 1.5 mm/s | 1.7 mm/s |
| P-01 | DE-H | 1.8 mm/s | 3.1 mm/s |
| FAN-01 | DE-H | 2.0 mm/s | 2.1 mm/s |
This makes changes much easier to see.
Add Percentage Change Carefully
You may also calculate percentage change.
For example:
Baseline:
1.5 mm/s
Current:
2.1 mm/s
Increase:
40%
However, percentage change should not be treated as an automatic machine alarm.
It is an additional trend indicator.
Machine condition still needs proper interpretation.
What Should Trigger Investigation?
Possible triggers include:
-
Sudden vibration increase
-
Sustained upward trend
-
Unusual difference between similar points
-
New abnormal noise
-
Increased temperature
-
Recent maintenance followed by higher vibration
-
Significant change in operating behaviour
-
Exceeding applicable machine criteria
The response should match machine criticality and risk.
After Bearing Replacement
Do not simply replace a bearing and close the job.
Take a new vibration measurement.
This provides a useful:
Post-maintenance baseline
For example:
Before repair:
4.8 mm/s
After bearing replacement:
1.7 mm/s
Record the result.
Future readings can now be compared against the new baseline.
After Shaft Alignment
The same principle applies after alignment.
Record vibration:
Before alignment
and:
After alignment
This helps demonstrate whether the maintenance work improved machine behaviour.
After Fan Balancing
For fan balancing work, record vibration before and after the corrective action.
Example:
Before: 6.1 mm/s RMS
After: 1.9 mm/s RMS
This creates valuable maintenance evidence.
These numbers are examples only, not universal acceptance limits.
Which Vibration Meter Is Suitable for a Checklist Programme?
MTM Precision currently carries six ready-stock vibration meter models.
LANDTEK VM-6310
The LANDTEK VM-6310 is particularly suitable for straightforward routine vibration velocity monitoring.
Its velocity measurement capability includes:
0.01–200 mm/s RMS
with:
10 Hz–1 kHz frequency range
For maintenance routes where technicians mainly record overall vibration in mm/s RMS, VM-6310 is a practical choice.
LANDTEK VM-6360
The LANDTEK VM-6360 measures:
-
Acceleration
-
Velocity
-
Displacement
It is more suitable when a maintenance checklist requires several vibration parameters.
SMART SENSOR AR63B
The SMART SENSOR AR63B also provides:
-
Acceleration
-
Velocity
-
Displacement
It is relevant for customers requiring broader vibration measurement capability, including acceleration measurement.
WINTACT WT63A
The WINTACT WT63A provides a portable option for routine machinery checks.
WINTACT WT63B
The WINTACT WT63B provides another WINTACT choice for preventive maintenance and general vibration inspection.
BENETECH GM63B
The BENETECH GM63B uses an external vibration sensor arrangement and provides another practical configuration for machine inspection.
Which Model for a Maintenance Team?
| Requirement | Suggested Direction |
|---|---|
| Simple mm/s checklist | LANDTEK VM-6310 |
| Monthly motor / pump route | VM-6310 |
| Acceleration + Velocity + Displacement | VM-6360 / AR63B |
| Economical portable inspection | WT63A / WT63B |
| External sensor configuration | GM63B |
| FFT / advanced diagnostics | Consider vibration analyzer |
Common Checklist Mistakes
Recording Only the Vibration Number
Always include parameter, unit and location.
Different Technician, Different Measurement Point
Define the measurement points clearly.
No Baseline
Start collecting baseline data while machines are healthy.
No Historical Records
Never overwrite the previous reading without retaining the history.
No RPM Information on Variable-Speed Equipment
Speed provides important context.
No Action Column
A checklist should help maintenance decisions, not merely collect numbers.
Treating Every Increase as Bearing Failure
Investigate the actual cause.
Applying One Alarm Limit to Every Machine
Use appropriate machine-specific evaluation criteria.
Downloadable-Style Checklist Structure
If you are building your own Excel or CMMS form, use these fields:
Asset ID
Equipment Name
Location
Criticality
Date
Technician
Operating Hours
RPM
Load / Operating Condition
Measurement Point
Direction
Parameter
Unit
Baseline Reading
Previous Reading
Current Reading
Trend
Noise Observation
Temperature Observation
Visual Condition
Action Required
Next Inspection Date
That is already enough to create a useful basic vibration monitoring programme.
FAQ – Vibration Monitoring Checklist
What should be included in a vibration monitoring checklist?
Include asset ID, measurement location, direction, vibration parameter, unit, operating condition, current reading, previous readings, trend and required follow-up.
What vibration parameter should be recorded?
For routine overall rotating machinery monitoring, vibration velocity in mm/s RMS is commonly useful.
Should motor DE and NDE both be measured?
Where appropriate, measurements around both Drive End and Non-Drive End bearing locations can provide useful condition information.
Should I record RPM?
Yes, especially for variable-speed equipment or where operating speed can change between inspections.
How often should the checklist be completed?
The interval depends on machine criticality and condition. Monthly measurement can be a practical starting point for many routine machines.
Should I use ISO 20816 limits?
Where formal vibration evaluation is required, use the relevant evaluation criteria applicable to the specific machine rather than a generic vibration limit.
Can Excel be used for vibration trending?
Yes. A simple spreadsheet can be sufficient for recording and trending routine vibration measurements.
Which vibration meter is suitable for a maintenance checklist?
For straightforward mm/s RMS monitoring, LANDTEK VM-6310 is a practical choice. For acceleration, velocity and displacement, compare LANDTEK VM-6360 and SMART SENSOR AR63B.
Where can I buy a vibration meter in Malaysia?
MTM Precision supplies ready-stock vibration meters from LANDTEK, WINTACT, BENETECH and SMART SENSOR for preventive maintenance, machinery inspection and condition monitoring applications in Malaysia.
Need a Vibration Meter for Your Maintenance Team?
Tell MTM Precision:
What machines are you monitoring?
Motor / Pump / Fan / Blower / Compressor / Generator / Cooling Tower / HVAC Equipment
How many machines?
How often do you plan to inspect them?
and:
Do you require velocity only or acceleration + velocity + displacement?
We can help you select a suitable vibration meter according to the actual maintenance application.
Contact MTM Precision
MTM Precision Sdn Bhd
No. 29-1 & 29-2, Jalan Bandar 18
Pusat Bandar Puchong
47160 Puchong, Selangor, Malaysia
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Contact MTM Precision for vibration meter selection, comparison, quotation and product availability in Malaysia.
Published Date: 26 August 2026
26 Aug 2026