Outdoor air quality and indoor air quality are connected, but they are not always identical.

 

During haze in Malaysia, outdoor pollution can enter homes and workplaces through doors, windows, ventilation systems and gaps in the building. However, indoor activities such as cooking, smoking and burning incense can also increase PM2.5.

 

The Temtop M10i measures local:

 

PM2.5

 

HCHO (formaldehyde)

 

TVOC

 

AQI

 

Its WiFi connectivity and historical records can help users observe how indoor PM2.5 changes when outdoor conditions, ventilation and room activities change.

 

Why Compare Indoor and Outdoor PM2.5?

 

An indoor and outdoor comparison can help answer questions such as:

 

Is outdoor haze entering the building?

 

Which room is better protected?

 

Does closing the window reduce PM2.5?

 

Is an air purifier making a measurable difference?

 

Does opening the main entrance affect indoor air?

 

Is indoor cooking producing more particles than outdoor haze?

 

Did filter replacement improve indoor conditions?

 

Without local measurement, users may assume indoor air is clean simply because the room looks clear or has air conditioning.

 

Official Outdoor Readings vs Local Measurements

 

Malaysia’s official IPU/API is published by the Department of Environment through APIMS.

 

It provides regional information based on official monitoring stations. A Temtop M10i reading represents only the location where the instrument is placed.

 

These values should not be treated as interchangeable because they may differ in:

 

Measurement location

 

Pollutants included

 

Calculation standard

 

Averaging period

 

Instrument type

 

Update time

 

Local surroundings

 

Use APIMS to understand regional outdoor conditions and the M10i to investigate a specific home or workplace.

 

How to Take an Indoor Baseline Reading

 

Before checking outdoors:

 

Place the M10i at normal breathing height.

 

Choose an occupied and representative room.

 

Keep its air inlets unobstructed.

 

Avoid direct airflow from an air conditioner.

 

Keep it away from cooking, smoking and aerosol sprays.

 

Record whether doors and windows are open.

 

Allow the reading to stabilise.

 

Record the PM2.5 value and time.

 

This becomes the indoor baseline.

 

How to Take an Outdoor Comparison Reading

 

The M10i is primarily intended for indoor air-quality monitoring. If it is used briefly for an outdoor comparison, protect it from:

 

Rain

 

Direct sunlight

 

Condensation

 

Excessive heat

 

Strong wind

 

Dust deposition

 

Water splashes

 

Do not leave the instrument permanently outdoors unless the manufacturer specifically approves that installation.

 

For a brief comparison:

 

Move the monitor to a sheltered outdoor location.

 

Keep it away from direct vehicle exhaust or cigarette smoke.

 

Avoid placing it immediately beside a wall or doorway.

 

Allow sufficient response time.

 

Record the reading and conditions.

 

Return it indoors and allow it to respond again.

 

Use consistent monitoring durations when comparing results.

 

Why Can Indoor PM2.5 Be Lower?

 

Indoor PM2.5 may be lower than outdoor PM2.5 when:

 

Windows and doors remain closed

 

The building is relatively airtight

 

Air purifiers are operating

 

Air-conditioning filters are effective

 

Entry doors are opened infrequently

 

No major indoor particle sources are present

 

A lower indoor reading suggests the building and filtration measures are reducing particle entry at that location.

 

However, conditions can change when doors open, filters become dirty or outdoor haze intensifies.

 

Why Can Indoor PM2.5 Be Higher?

 

Indoor PM2.5 can exceed the outdoor reading because of:

 

Cooking

 

Smoking

 

Incense

 

Candles

 

Aerosol use

 

Indoor renovation

 

Cleaning activities

 

Resuspension of settled dust

 

Poor ventilation

 

Local outdoor sources close to the room

 

For example, a kitchen may record higher PM2.5 during cooking even when the regional outdoor air quality is moderate.

 

A high indoor reading does not automatically prove that haze is the source.

 

The Importance of Timing

 

Indoor and outdoor readings should be taken as close together as practical because PM2.5 can change quickly.

 

Avoid comparing:

 

An indoor morning reading with an outdoor evening reading

 

A purifier-on result with an outdoor result taken before haze intensified

 

A closed-room reading with an outdoor measurement from a different day

 

For a meaningful comparison, record:

 

Date and time

 

Location

 

Doors and windows

 

Weather

 

Purifier status

 

Air-conditioning status

 

Indoor activities

 

Monitoring duration

 

Understanding the Indoor-to-Outdoor Relationship

 

A simple comparison can be calculated as:

 

Indoor PM2.5 ÷ Outdoor PM2.5

 

For example:

 

Indoor PM2.5: 30 µg/m³

 

Outdoor PM2.5: 60 µg/m³

 

Indoor-to-outdoor ratio: 0.5

 

This means the indoor reading is approximately half the outdoor reading at the times and locations measured.

 

However, this is only a practical comparison. It is not a formal building-performance assessment because conditions and instruments may vary.

 

How to Compare Rooms During Haze

 

Use the same monitor to check:

 

A room facing the road

 

An internal room

 

A room with an air purifier

 

A room without an air purifier

 

An upper floor

 

A ground-floor entrance area

 

Keep the monitor at a similar height and use the same observation period.

 

Allow it sufficient time to respond after moving to each location.

 

This can help identify the room with the lowest PM2.5 for use during severe haze.

 

PM2.5 Is Not the Only Indoor Concern

 

Closing windows can reduce the entry of outdoor particles, but it may also reduce ventilation.

 

In an enclosed room:

 

TVOC may increase

 

Formaldehyde may accumulate

 

CO₂ may rise when people are present

 

Temperature and humidity may change

 

The M10i monitors PM2.5, HCHO and TVOC, allowing users to observe some of these trade-offs.

 

It does not measure CO₂. When ventilation is a priority, a CO₂-capable monitor such as the Temtop M100 may be more appropriate.

 

Common Comparison Mistakes

 

Avoid:

 

Comparing readings taken at very different times

 

Placing the monitor beside vehicle exhaust

 

Taking one reading beside an open doorway

 

Exposing the monitor to rain

 

Comparing different rooms without allowing response time

 

Testing while cooking or smoking

 

Positioning the instrument beside a purifier outlet

 

Treating its AQI as official Malaysia IPU

 

Assuming one result represents the entire building

 

Consistent methodology is more important than collecting many unrelated readings.

 

Who Can Benefit From Indoor vs Outdoor Monitoring?

 

This type of comparison is useful for:

 

Homeowners

 

Families during haze

 

Offices

 

Schools and childcare centres

 

Hotels

 

Serviced apartments

 

Property managers

 

Facilities teams

 

Homes using air purifiers

 

Building-maintenance personnel

 

Larger premises may need multiple monitors or a professionally designed monitoring plan.

 

Contact MTM Precision

 

Contact MTM Precision for assistance selecting a Temtop indoor PM2.5 monitor for haze and air-quality comparisons in Malaysia.

 

MTM Precision Sdn. Bhd.

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

29 Aug 2026