A handheld meter shows the condition at one moment. A temperature and humidity data logger records measurements automatically over hours, days or weeks.
This allows maintenance and quality teams to identify heat buildup, excessive humidity, condensation risk, HVAC problems and environmental changes that may otherwise go unnoticed.
What Is a Temperature and Humidity Data Logger?
A data logger contains sensors, memory and an internal clock.
It records measurements at a selected interval, such as:
Every minute
Every five minutes
Every 15 minutes
Every hour
Depending on the model, stored results may be viewed through:
A built-in display
USB connection
Bluetooth
Wi-Fi
Mobile application
Computer software
Cloud platform
Not every data logger supports every connection method.
Why Use a Data Logger Instead of a Handheld Meter?
FeatureData LoggerHandheld MeterMeasurement styleAutomatic continuous recordingManual spot measurementUnattended monitoringYesNoOvernight dataAvailableUsually unavailableTrend graphAvailable on suitable softwareLimitedAlarm historyAvailable on suitable modelsUsually limitedBest useLong-term environmental monitoringImmediate on-site checks
Many factories use both instruments.
Factory Applications
Temperature and humidity data loggers may be used in:
Production areas
Raw-material warehouses
Finished-goods warehouses
Electrical rooms
Control rooms
Compressor rooms
Boiler rooms
Laboratories
Cleanrooms
Cold rooms
Refrigerators
Freezers
Food-processing areas
Pharmaceutical storage
Chemical storage
Server rooms
1. Warehouse Monitoring
High humidity can affect:
Packaging
Paper products
Electronic components
Metal parts
Powder materials
Chemicals
Textiles
Finished products
Possible problems include:
Corrosion
Mould
Condensation
Material clumping
Packaging damage
Product deterioration
Place loggers at representative locations rather than only near the entrance or air-conditioning outlet.
2. Production Area Monitoring
Some production processes require stable environmental conditions.
Temperature and humidity changes may affect:
Product dimensions
Coating application
Adhesive curing
Electronics assembly
Printing
Food processing
Laboratory work
Measurement accuracy
Employee comfort
A logger provides evidence of when and how long conditions moved outside the required range.
3. Electrical Room Monitoring
Electrical panels, drives, transformers and control equipment generate heat.
High room temperature may result from:
Failed ventilation fan
Blocked filter
Air-conditioning problem
Overloaded electrical equipment
Hot-air recirculation
Open doors
Poor room design
High humidity can contribute to condensation and corrosion.
Use environmental data together with thermal inspection of electrical equipment.
4. Compressor Room Monitoring
Air compressors generate significant heat.
A data logger can record:
Daytime temperature
Night-time temperature
Peak temperature
Humidity
Duration of high-temperature conditions
Changes after ventilation improvements
This helps determine whether high compressor temperature is related to machine condition or the surrounding room environment.
5. Boiler Room Monitoring
Boiler rooms may experience high temperature and changing ventilation conditions.
Environmental logging helps maintenance teams evaluate:
Heat accumulation
Ventilation performance
Temperature near electrical controls
Difference between operating and shutdown periods
Humidity and condensation conditions
The logger must be suitable for the expected temperature and installation location.
6. HVAC Performance Checks
A data logger can support investigation of:
Intermittent cooling problems
Temperature fluctuations
High humidity
Night-time HVAC shutdown
Unstable thermostat control
Uneven conditions between rooms
Slow recovery after doors open
Condensation complaints
Several loggers may be required to compare different areas.
7. Cold Room and Refrigerator Monitoring
Cold-storage applications may require continuous temperature records.
Potential applications include:
Food storage
Pharmaceutical products
Laboratory samples
Chemicals
Temperature-sensitive materials
Refrigerated transport preparation
Depending on the application, select a logger designed for:
Internal sensor measurement
External probe measurement
Temperature only
Temperature and humidity
Remote alarm notification
Local USB reporting
8. Cleanroom and Controlled Area Monitoring
Controlled areas may require monitoring of:
Temperature
Relative humidity
Differential pressure
Particle concentration
Air velocity
A temperature-humidity logger covers only part of the complete environmental-monitoring requirement.
The monitoring programme should follow the process and facility requirements.
Understanding Relative Humidity
Relative humidity describes the amount of water vapour in the air relative to the maximum amount the air can hold at that temperature.
Because warm air can hold more moisture than cold air, relative humidity may change when temperature changes even if the actual moisture content remains similar.
Temperature and humidity should therefore be evaluated together.
Understanding Dew Point
Dew point is the temperature at which moisture begins to condense.
Condensation may occur when a surface becomes colder than the surrounding air’s dew point.
This can affect:
Chilled-water pipes
Cold-room doors
Metal equipment
Electrical cabinets
Building surfaces
Air-conditioning ducts
Some loggers or software can calculate dew point from temperature and humidity data.
Selecting the Logging Interval
A short interval provides more detail but uses memory and battery capacity more quickly.
A longer interval provides a longer monitoring period but may miss brief changes.
Consider:
How quickly conditions can change
Required monitoring duration
Available memory
Battery capacity
Reporting needs
Alarm requirements
For troubleshooting intermittent problems, a shorter interval may be useful.
Where Should a Data Logger Be Placed?
Avoid placing the logger:
Directly beside an air-conditioning outlet
In direct sunlight
Against a hot machine
Beside an open door
Near a humidifier unless that is the target area
Against an exterior wall without considering its effect
Where water can enter the device
Where it can be damaged by machinery
Select a representative location for the area being monitored.
How Many Data Loggers Are Needed?
One logger may not represent a large warehouse or production area.
Multiple units may be required to compare:
High and low storage levels
Near-door and central locations
Different production zones
Air-conditioned and non-air-conditioned areas
Supply and return air
Hot and cold spots
Different refrigerators or freezers
The number depends on the area size, layout, airflow and monitoring objective.
Elitech Data Logger Options
MTM Precision supplies several Elitech temperature and humidity monitoring products, including:
Elitech GSP-6 Pro
Elitech RC-5
Elitech RC-5+
Elitech RC-51H
Elitech RC-4HC
Elitech BT-3
Elitech RCW-360 Pro
These models serve different monitoring requirements.
Before selecting a model, confirm whether the application needs:
Temperature only
Temperature and humidity
Internal or external probe
USB reporting
Bluetooth
Wi-Fi
Remote alarm
Cloud access
Local display
USB vs Bluetooth vs Wi-Fi Data Loggers
USB Data Logger
Suitable for local recording and later report download.
Bluetooth Data Logger
Allows nearby users to retrieve data using a compatible mobile device.
Wi-Fi Data Logger
Can support remote viewing or alerts when connected to a suitable network and platform.
Wi-Fi monitoring depends on network availability, account setup and system configuration.
Alarm Functions
Depending on the model, alarm features may include:
High-temperature alarm
Low-temperature alarm
High-humidity alarm
Low-humidity alarm
Audible alarm
Visual alarm
Mobile notification
Email notification
Cloud alarm
Alarm-history record
A local logger without remote communication cannot send an alert to someone outside the site.
How to Perform a Monitoring Study
Step 1: Define the Objective
Identify whether the problem concerns temperature, humidity, condensation, HVAC operation or product storage.
Step 2: Select Suitable Loggers
Choose the required sensor, range, connectivity and protection.
Step 3: Choose Measurement Locations
Document every logger location with photographs or a layout plan.
Step 4: Set the Logging Interval
Balance detail, memory and monitoring duration.
Step 5: Start the Logger
Confirm the date, time, battery and recording status.
Step 6: Leave It Undisturbed
Avoid moving the logger during the study unless the movement is documented.
Step 7: Download and Review the Data
Look for peak values, duration, timing and differences between locations.
Step 8: Investigate the Cause
Compare results with HVAC schedules, production activity, weather, door opening and equipment operation.
What Should Be Included in a Monitoring Report?
A useful report may include:
Monitoring objective
Logger model
Logger identification
Measurement location
Start and end time
Logging interval
Temperature graph
Humidity graph
Maximum and minimum values
Alarm events
Site observations
Corrective actions
Common Data Logging Mistakes
Avoid:
Starting the logger with the wrong date or time
Using an unsuitable logging interval
Placing the logger beside an air-conditioning outlet
Monitoring a large warehouse with only one poorly located unit
Ignoring sensor response time
Blocking the sensor openings
Moving the logger without documenting it
Allowing the battery to expire
Assuming Wi-Fi models will work without network setup
Downloading data without checking the measurement location
Confusing air temperature with product-core temperature
Ignoring door-opening and production schedules
How to Choose a Temperature and Humidity Data Logger
Consider:
Measurement Parameters
Choose temperature only or temperature and humidity.
Sensor Type
Select internal, external or remote probe according to the application.
Measurement Range
Ensure the logger covers the expected environment.
Accuracy
Select performance appropriate for the process requirement.
Memory Capacity
Confirm it can store the required number of readings.
Logging Interval
Check the available interval settings.
Connectivity
Choose USB, Bluetooth, Wi-Fi or cloud monitoring.
Alarm Requirement
Decide whether local or remote alerts are necessary.
Environmental Protection
Consider water, dust, condensation and physical damage.
Reporting Software
Check whether the software produces the required graph and report format.
Data Logger vs Real-Time Monitor
InstrumentMain UseData loggerRecord conditions for later reviewWi-Fi or cloud monitorRemote viewing and alertsHandheld meterImmediate spot checksInfrared thermometerSurface-temperature measurementThermal imaging cameraTemperature-pattern inspection
Temperature and Humidity Data Logger Supplier in Malaysia
MTM Precision supplies data loggers for factory production areas, warehouses, electrical rooms, HVAC systems, cold rooms, refrigerators and temperature-sensitive storage.
Available options include Elitech GSP-6 Pro, RC-5, RC-5+, RC-51H, RC-4HC, BT-3 and RCW-360 Pro.
We can help customers compare sensor type, temperature range, humidity monitoring, USB reporting, Bluetooth, Wi-Fi and remote alarm requirements before selecting a suitable model.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
31 Aug 2026