How to Use Benetech GM63B to Check Motor Vibration Malaysia
How to Use Benetech GM63B to Check Motor Vibration Malaysia
Electric motors are used throughout factories, workshops, HVAC systems, pumps, fans, compressors and production equipment. When a motor starts producing unusual vibration, it may be an early indication that its mechanical or operating condition has changed.
The Benetech GM63B Vibration Meter can be used as a portable tool for routine motor vibration checks and preventive maintenance.
For maintenance teams in Malaysia, the important question is not simply how to obtain one vibration reading, but how to measure consistently and use the results to identify changes over time.
Why Check Electric Motor Vibration?
A motor may continue running even when its condition is beginning to deteriorate.
Abnormal vibration can be associated with several possible conditions, including:
Rotor imbalance
Shaft or coupling misalignment
Bearing deterioration
Mechanical looseness
Weak mounting
Problems with connected equipment
Changes in operating load
A vibration reading alone does not automatically identify which fault is present. However, it can provide an early indication that further inspection is required.
Where Should You Measure Motor Vibration?
For routine checks, technicians commonly take measurements around the motor's bearing locations or other suitable rigid measurement points.
For a typical motor:
Drive End (DE) → Motor Body → Non-Drive End (NDE)
If the motor is connected to a pump, fan or other rotating equipment, measurements can also be taken on the connected machine.
For example:
Motor NDE → Motor DE → Coupling → Pump DE → Pump NDE
The objective is to create repeatable measurement locations that can be checked again during future inspections.
Step 1 – Inspect the Motor Before Measuring
Before taking vibration measurements, perform a basic visual inspection.
Look for obvious problems such as:
Loose mounting bolts
Damaged motor feet
Unusual noise
Excessive heat
Loose guards
Visible movement
Damaged coupling components
If there is an obvious safety or mechanical problem, it should be addressed according to the site's maintenance procedures.
Step 2 – Choose Consistent Measurement Points
Consistency is extremely important.
Avoid randomly measuring a different position every time.
Instead, identify repeatable points around the motor and record them as part of your maintenance procedure.
For example:
Point A – Drive-end bearing housing
Point B – Non-drive-end bearing housing
The same points can then be checked during every maintenance inspection.
Step 3 – Take the Vibration Measurement
Place the vibration sensor firmly at the selected measurement location according to the instrument instructions.
Avoid unstable contact.
The way the sensor contacts the machine can influence measurement repeatability, so technicians should use a consistent measurement technique whenever possible.
Allow the reading to stabilise before recording the result.
Step 4 – Record the Reading
Don't simply look at the number and walk away.
Record it.
A basic maintenance record might contain:
Machine: Motor No. 05
Location: Production Line 2
Point: Drive End
Date: Inspection date
Operating Condition: Normal production load
Reading: Recorded vibration value
Remarks: Normal / unusual noise / temperature increase / other observation
This information becomes increasingly useful after several inspection cycles.
Step 5 – Compare with Previous Measurements
Suppose a motor produces relatively consistent readings over several inspections.
Then one month the reading increases noticeably.
That change may be more useful than looking at the latest number in isolation.
A simple trend could look like:
Inspection 1 → Stable
Inspection 2 → Stable
Inspection 3 → Slight increase
Inspection 4 → Significant increase
At this point, the maintenance team may decide to investigate the motor, bearing, coupling, alignment, mounting or connected equipment.
Why Baseline Measurements Matter
Different machines can naturally operate at different vibration levels.
This is why establishing a baseline is useful.
When equipment is known to be operating normally, record its vibration condition.
Future measurements can then be compared against that reference.
For factories with many motors, this approach can gradually create a useful condition history for critical equipment.
Can GM63B Tell You What Is Wrong with the Motor?
Not automatically.
A vibration meter measures vibration; it should not be treated as an automatic fault diagnosis machine.
For example, an increased reading may justify checking:
Bearing condition
Alignment
Balance
Mounting
Coupling
Operating load
Connected pump, fan or gearbox
Experienced technicians can combine vibration readings with other maintenance information to determine what should be inspected next.
Motor Vibration and Pump Problems
Sometimes the motor itself is not the only possible source of vibration.
Consider a motor-driven pump:
Motor → Coupling → Pump
Vibration generated by the pump, coupling or installation may also be transmitted through the assembly.
This is why measuring several locations can provide more useful information than measuring only one point on the motor.
Motor Vibration and Fan Systems
The same principle applies to fans and blowers.
If a motor drives a fan, abnormal vibration may originate from several areas:
Motor → Belt/Coupling → Fan Shaft → Bearing → Impeller
Possible causes may include mechanical looseness, imbalance, bearing condition or problems elsewhere in the rotating assembly.
A systematic measurement route can help technicians determine where further investigation is required.
Create a Motor Vibration Inspection Route
Factories with many motors can incorporate vibration measurements into scheduled preventive maintenance.
For example:
Motor 01 – Cooling Pump
Motor 02 – Exhaust Fan
Motor 03 – Compressor
Motor 04 – Production Machine
Motor 05 – Water Pump
Measure the same points at planned intervals and keep the results.
This is much more valuable than waiting until a machine becomes noisy or stops operating.
Who Can Use the Benetech GM63B?
The GM63B can be considered for routine vibration measurement by:
Factory maintenance departments
Mechanical technicians
Facility management teams
HVAC contractors
Pump maintenance companies
Motor service technicians
Building maintenance teams
Industrial service contractors
Its portable format makes it useful for technicians who need to move between different machines during routine inspection work.
Looking for a Motor Vibration Meter in Malaysia?
If you need a portable vibration meter for checking electric motors, pumps, bearings, fans, blowers or other rotating machinery, the Benetech GM63B is one option to consider.
The correct instrument should be selected according to the required measurement application, machine type and maintenance objective.
MTM Precision can assist Malaysian users in selecting a suitable vibration meter for factory and maintenance applications.
Contact MTM Precision
MTM Precision Sdn Bhd
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Contact MTM Precision for Benetech GM63B Vibration Meter Malaysia, motor vibration testing equipment and vibration measurement solutions for industrial preventive maintenance.
05 Sep 2026