How to Check Temperature and Humidity in a Factory Malaysia
How to Check Temperature and Humidity in a Factory Malaysia
Checking temperature and humidity inside a factory involves more than taking one reading in the middle of the production floor.
Factories can have very different environmental conditions between production lines, warehouses, electrical rooms, loading bays and air-conditioned areas.
A practical approach is to use a portable temperature and humidity meter, such as the Benetech GM1361, and compare readings from several representative locations.
Step 1: Identify the Areas You Need to Check
Before taking measurements, determine which parts of the factory are important.
Typical locations may include:
Production areas
Raw material storage
Finished goods warehouses
Electrical rooms
Control rooms
Laboratories
Quality control areas
Loading bays
Air-conditioned rooms
Areas where workers have reported heat or humidity problems
Avoid assuming that one measurement represents the entire factory.
Step 2: Use a Temperature and Humidity Meter
For routine spot checks, a handheld instrument is convenient because technicians can move between different locations.
The Benetech GM1361 Temperature & Humidity Meter can be used to obtain immediate environmental temperature and relative humidity readings during an inspection.
This type of meter is particularly useful when the objective is to answer:
“What are the temperature and humidity conditions at this location right now?”
Step 3: Allow the Reading to Stabilize
When moving from one environment to another, avoid immediately recording the first value displayed.
Give the instrument sufficient time to respond to the new environment and allow the reading to stabilize before recording the result.
This is particularly important when moving between areas with noticeably different environmental conditions, such as from an air-conditioned office to a warm production floor.
Step 4: Measure at Several Locations
A factory inspection should normally involve multiple measurement points.
For example:
Point A: Production floor
Point B: Warehouse
Point C: Electrical room
Point D: Quality control area
Point E: Loading bay
Point F: Air-conditioned control room
Record the temperature and relative humidity at each point.
The objective is not simply to collect numbers. It is to identify differences between locations.
Step 5: Compare Normal and Problem Areas
If workers report that a particular section feels unusually hot or humid, compare it with an area operating under normal conditions.
For example:
Normal production area → Take a reading
Reported hot area → Take a reading
Near ventilation outlet → Take a reading
Near doorway or loading bay → Take a reading
This comparison provides useful information for maintenance personnel before further investigation.
Step 6: Consider What May Be Causing the Difference
If measurements show a noticeable difference between areas, investigate possible causes.
These may include:
Poor airflow
HVAC performance
Heat generated by machinery
Production processes
Open doors
Outdoor air entering the building
Sun exposure
Ventilation problems
Location of air-conditioning outlets
Building layout
A temperature and humidity meter identifies the environmental condition. It does not by itself identify the cause of the problem.
Further inspection may therefore be necessary.
Step 7: Decide Whether You Need Continuous Monitoring
A handheld meter such as the Benetech GM1361 is useful for immediate spot checks.
However, suppose a factory manager asks:
“Why does this room become humid every afternoon?”
One measurement may not answer that question.
In this situation, continuous monitoring may be more useful.
A temperature and humidity data logger, such as the Benetech GM1365, can record environmental conditions over an extended period.
This allows users to review how temperature and humidity change throughout the day.
A simple rule is:
Immediate measurement → GM1361
Continuous recording → Temperature & Humidity Data Logger
Example: Investigating a Humid Warehouse Area
Imagine that a factory warehouse has one storage section that frequently feels more humid than the rest of the building.
A maintenance technician could:
Measure temperature and RH in a normal storage area.
Measure the suspected humid area.
Check near the loading door.
Check near the air-conditioning or ventilation outlet.
Compare the readings.
Investigate possible sources if a significant difference is found.
If the condition appears only at certain times, a data logger can then be installed for longer-term monitoring.
This approach is more useful than relying only on how the environment feels.
Other Measurements May Also Be Required
Temperature and humidity are only two parameters used in factory environmental inspection.
Depending on the problem, technicians may also need instruments for:
Air velocity
Differential pressure
CO₂
Particulate matter
VOC
Sound level
Illuminance
Gas detection
Surface temperature
Thermal imaging
The correct instrument depends on the problem being investigated.
Benetech GM1361 for Factory Temperature and Humidity Checks
The Benetech GM1361 Temperature & Humidity Meter is suitable for technicians who need a portable instrument for routine environmental spot checks.
It can be considered for:
Factory maintenance
HVAC inspection
Warehouse monitoring
Facility management
Laboratory checks
Indoor environmental monitoring
Food and logistics applications
For users who need to move between several inspection points, a handheld meter provides a simple and practical measurement method.
Looking for a Temperature and Humidity Meter in Malaysia?
MTM Precision supplies the Benetech GM1361 Temperature & Humidity Meter in Malaysia, together with environmental, safety and industrial maintenance instruments.
For continuous temperature and humidity monitoring applications, customers can also consider suitable data logger solutions.
Contact MTM Precision
MTM Precision Sdn Bhd
No. 29-1 & 29-2, Jalan Bandar 18
Pusat Bandar Puchong
47160 Puchong, Selangor, Malaysia
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Contact MTM Precision for Benetech GM1361 Temperature & Humidity Meter Malaysia and suitable factory environmental monitoring instruments.