PM2.5 Air Quality Monitor for Sarawak Schools During Haze Malaysia

Meta Description: Learn how Sarawak schools can use PM2.5 air quality monitors during severe haze to check classrooms, evaluate air purifiers and document indoor particle levels.

PM2.5 Air Quality Monitor for Sarawak Schools During Haze Malaysia

Severe haze in Sarawak can disrupt school operations and affect the air inside classrooms, libraries, staff rooms and school halls.

On 4 September 2026, an emergency was declared in Serian after the Air Pollutant Index exceeded 500. Schools in affected areas were closed as authorities responded to the hazardous conditions.

Schools must always follow the latest instructions issued by the relevant Malaysian and Sarawak authorities. A portable PM2.5 air quality monitor does not determine whether a school should open or close.

Its role is to help school administrators and facility teams understand the air quality inside individual rooms when indoor assessment is required.

Why the Official API and Classroom PM2.5 Are Different

The official Air Pollutant Index—API describes the general outdoor air-quality condition around a monitoring area.

A classroom PM2.5 monitor measures fine particles at the instrument’s location.

Official API Classroom PM2.5 Monitor
Represents regional outdoor conditions Measures a particular indoor location
Reported as an index Normally reported in µg/m³
Used for public warnings and official decisions Used for local investigation
Based on official monitoring stations Based on the portable monitor
Does not represent every classroom Can compare individual rooms

Schools need the official API for government guidance. Local PM2.5 measurements provide additional information about the building.

Why Classrooms May Have Different Readings

Two classrooms in the same school may show different PM2.5 levels.

Possible reasons include:

  • One classroom has open windows

  • One room is air-conditioned

  • An air purifier operates in only one room

  • One classroom is closer to the main road

  • Students use different entrances

  • Doors are opened at different frequencies

  • The rooms have different levels of air leakage

  • Air-conditioning filters have different conditions

  • One space is closer to an outdoor pollution source

This is why a single reading taken in the school office cannot represent the entire campus.

Which Areas Should a Sarawak School Check?

A basic monitoring plan may include:

  • Classrooms

  • Kindergarten rooms

  • School office

  • Staff room

  • Library

  • Computer room

  • Sick bay

  • Indoor hall

  • Canteen

  • Guardhouse

  • Covered waiting area

  • Rooms near the main entrance

  • Rooms beside a busy road

  • Rooms using air purifiers

Priority should be given to frequently occupied spaces and areas serving younger children or other vulnerable occupants.

What Should the Monitor Measure?

For haze monitoring, the main parameter is:

PM2.5

PM2.5 refers to fine airborne particles with a diameter of 2.5 micrometres or smaller.

A suitable school air quality monitor may also include:

  • PM10

  • Carbon dioxide

  • Temperature

  • Relative humidity

  • Formaldehyde

  • TVOC

  • Data logging

  • Adjustable alarms

A CO₂-only monitor is not suitable for measuring haze particles. The instrument must include PM2.5 measurement.

How to Position the Monitor in a Classroom

Place the monitor:

  • In a representative occupied area

  • At a suitable breathing-zone height

  • On a stable surface

  • Away from direct sunlight

  • Where students cannot easily interfere with it

  • Where air can circulate around the sensor

Avoid positioning it:

  • Directly beside an air purifier

  • Under an air-conditioning outlet

  • Immediately next to a window

  • Beside the classroom door

  • Near a whiteboard duster

  • Near a kitchen or canteen exhaust

  • Inside a cabinet

  • Beside a local dust source

A meter placed directly in front of an air purifier may show freshly filtered air rather than conditions across the classroom.

Suggested Classroom Monitoring Procedure

Step 1: Check the Latest Official API

Record the current API for the school’s area, together with the date and time.

Check whether any school-closure or activity instructions are in effect.

Step 2: Record the Room Condition

Before measuring, note:

  • Classroom name

  • Number of occupants

  • Window status

  • Door status

  • Air-conditioning status

  • Air purifier status

  • Recent cleaning or dusty activity

Step 3: Place the Monitor

Use a representative position and allow the reading to stabilise according to the instrument instructions.

Step 4: Record PM2.5

Record the actual PM2.5 value and PM10 where available.

Step 5: Repeat the Measurement

Measure again after changing one condition, such as:

  • Closing the windows

  • Starting the air purifier

  • Changing the purifier fan speed

  • Replacing the filter

Step 6: Compare Other Classrooms

Use the same monitor position, waiting period and procedure as consistently as possible.

Example School Monitoring Form

Date and Time Classroom PM2.5 Occupants Windows Purifier Remarks
Record Classroom A Record Record Open/Closed On/Off Record condition
Record Classroom B Record Record Open/Closed On/Off Record condition
Record Library Record Record Open/Closed On/Off Record condition
Record School office Record Record Open/Closed On/Off Record condition

The school should enter actual measurements. Do not use estimated values in an official monitoring record.

When Should Measurements Be Taken?

Useful monitoring times include:

  • Before students arrive

  • At the beginning of lessons

  • During peak occupancy

  • Before and after recess

  • After a classroom door has been open

  • After starting an air purifier

  • During afternoon lessons

  • Before dismissal

  • Whenever the official API changes significantly

One morning reading may not represent the entire school day.

For changing conditions, an instrument with data logging can provide a more complete record.

How to Test a Classroom Air Purifier

A PM2.5 monitor can help determine whether the purifier is reducing particles across the classroom.

  1. Follow all official instructions in effect.

  2. Close external windows and doors where appropriate.

  3. Position the monitor away from the purifier outlet.

  4. Record the initial PM2.5.

  5. Switch on the purifier.

  6. Record the fan-speed setting.

  7. Maintain consistent room conditions.

  8. Record PM2.5 at regular intervals.

  9. Repeat the test at the back of the classroom.

If the reading beside the purifier is low but remains high at the opposite side of the room, the purifier may not be circulating sufficient clean air throughout the classroom.

Why the PM2.5 Reading May Remain High

Purifier Is Too Small

A purifier intended for a bedroom may not be suitable for a large classroom.

Filter Requires Replacement

Severe haze may load particulate filters more quickly.

Windows or Doors Remain Open

Outdoor particles may enter faster than the purifier can remove them.

Fan Speed Is Too Low

A silent or sleep setting may not provide sufficient airflow during severe haze.

Purifier Position Is Poor

Furniture, walls or curtains may block the air intake or outlet.

Classroom Has Another Particle Source

Cleaning, dust, smoke, road traffic or nearby construction may influence the reading.

Air-Conditioning Does Not Guarantee Low PM2.5

An air-conditioned classroom may have lower particle levels when windows are closed and suitable filtration is maintained.

However, fine particles may still enter through:

  • Fresh-air intakes

  • Door openings

  • Gaps around windows

  • Poorly maintained filters

  • Building leakage

The only way to understand the actual classroom condition is to measure it correctly.

Why CO₂ May Also Matter

During haze, schools may close windows to reduce outdoor particle entry.

In a fully occupied classroom, CO₂ may rise when ventilation is limited. This does not mean that windows should be opened without considering the severe outdoor conditions.

Instead, schools should follow professional and official guidance while monitoring the different parameters involved.

A multi-parameter instrument such as the Temtop M2000 2nd can measure both PM2.5 and CO₂.

This allows a school to observe:

  • Particulate pollution

  • Occupancy-related CO₂

  • Temperature

  • Humidity

  • Formaldehyde

PM2.5 and CO₂ represent different indoor air-quality issues and must be interpreted separately.

Portable Meter or Fixed Monitor?

Portable PM2.5 Meter

Suitable for:

  • Comparing classrooms

  • Testing air purifiers

  • Finding particle-entry points

  • Conducting quick inspections

  • Sharing one instrument across the school

Fixed or Logging Monitor

Suitable for:

  • Continuous classroom monitoring

  • Recording the entire school day

  • Identifying pollution spikes

  • Monitoring rooms with vulnerable occupants

  • Maintaining historical records

  • Reviewing filtration performance

Schools may use a portable instrument for surveys and a fixed monitor in priority rooms.

Suitable Temtop Models

Temtop M2000 2nd

Suitable for schools requiring:

  • PM2.5

  • PM10

  • CO₂

  • HCHO

  • Temperature

  • Humidity

  • Data export

Its CO₂ measurement makes it particularly relevant to occupied classrooms and meeting rooms.

Temtop LKC-1000S+ 2nd

Suitable for schools requiring:

  • PM2.5

  • PM10

  • HCHO

  • TVOC

  • Temperature

  • Humidity

  • Data export

It may be useful when the school also needs to screen renovated rooms, new furniture or possible VOC conditions.

Temtop M10i

Suitable for users interested in compatible Wi-Fi monitoring and mobile access to indoor air-quality trends, subject to the exact supplied version.

Common School Monitoring Mistakes

Using a Portable Reading to Decide Whether School Should Open

School operations must follow official instructions.

Measuring Only in the Administration Office

Classroom conditions may be different.

Placing the Monitor Beside the Purifier

This may produce an unrealistically low representation of the room.

Recording PM2.5 Without the Room Conditions

Door, window, purifier and occupancy information is required for a meaningful comparison.

Assuming CO₂ and PM2.5 Are the Same

They measure different indoor air-quality conditions.

Taking One Reading and Stopping

Haze and classroom activity can change throughout the day.

Failing to Maintain the Instrument

Schools should follow the manufacturer’s instructions concerning storage, charging, cleaning and sensor operation.

What the Instrument Cannot Do

A PM2.5 monitor cannot:

  • Remove particles

  • Replace an air purifier

  • Replace the official API

  • Approve a school reopening

  • Override government directions

  • Provide medical diagnosis

  • Identify the chemical composition of particles

  • Replace formal occupational or environmental testing

It is a measurement tool used to support indoor assessment.

A Practical Haze Monitoring Plan for Sarawak Schools

A school haze-monitoring plan should include:

  1. Checking the latest official API

  2. Following closure and activity instructions

  3. Selecting representative classrooms

  4. Measuring PM2.5 consistently

  5. Recording room conditions

  6. Checking air purifier performance

  7. Reviewing filter maintenance

  8. Monitoring occupied enclosed rooms

  9. Keeping historical records where required

  10. Escalating health and operational decisions to the responsible authorities

During a severe Sarawak haze event, schools should never depend on visibility alone.

Official API information establishes the regional risk. Properly conducted PM2.5 measurements provide evidence about individual classrooms.

Contact MTM Precision

Contact MTM Precision for assistance selecting a PM2.5 Air Quality Monitor for schools and classrooms during haze in Sarawak, Malaysia.

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: 016-660 7346

07 Sep 2026