Why Is Dissolved Oxygen Low in Fish Pond? Causes & DO Testing Guide Malaysia
Why Is Dissolved Oxygen Low in Fish Pond? Causes & DO Testing Guide Malaysia
Low dissolved oxygen (DO) is one of the most important water-quality problems to investigate in a fish pond.
Fish depend on oxygen dissolved in water. However, pond DO can change considerably between morning and afternoon and may be affected by temperature, fish density, aeration, algae, feeding, organic waste and weather.
A pond that appears normal during the day can experience much lower oxygen conditions overnight.
For fish farms in Malaysia, the key principle is simple:
Don't guess whether dissolved oxygen is low — measure it.
A portable DO meter such as the Smart Sensor AR8407 can be used to measure dissolved oxygen directly while also checking pH, ammonia nitrogen, nitrite and temperature.
What Causes Low Dissolved Oxygen in a Fish Pond?
There is rarely only one possible cause.
Several conditions may occur at the same time.
1. High Water Temperature
Temperature has an important relationship with dissolved oxygen.
Warmer water generally holds less dissolved oxygen than cooler water.
This is particularly relevant for Malaysian aquaculture because ponds can experience warm conditions throughout the year.
At the same time, fish and microorganisms may have significant oxygen demand.
Therefore, always record:
DO + Water Temperature
rather than looking at the DO value without context.
2. High Fish Stocking Density
More fish means greater total oxygen demand.
As fish biomass increases, a pond that previously had sufficient aeration may require different management.
This is especially important in intensive aquaculture.
If stocking density has recently increased and DO readings begin trending downward, oxygen demand should be investigated.
3. Insufficient Aeration
Aeration equipment helps introduce oxygen and circulate pond water.
Possible issues include:
Insufficient aerator capacity
Poor aerator positioning
Mechanical failure
Electrical failure
Inadequate operating time
Increasing biomass without increasing aeration
Do not assume that an aerator is providing enough oxygen simply because it is running.
Measure DO at representative locations.
4. Too Much Uneaten Feed
Excess feed does more than increase operating costs.
Uneaten feed becomes organic material.
As it decomposes, microorganisms consume oxygen.
This can contribute to:
Higher oxygen demand + deteriorating water conditions
Feeding practice therefore has a direct relationship with water-quality management.
5. Fish Waste and Organic Sludge
Fish waste and other organic matter can accumulate in a pond.
Decomposition consumes oxygen.
Heavy organic loading may also influence other water-quality parameters, including nitrogen-related compounds.
If DO problems occur together with increasing ammonia or nitrite, investigate the overall organic load and pond condition.
6. Algae and Night-Time Respiration
Algae can make pond oxygen behaviour confusing.
During daylight, photosynthesis can contribute oxygen.
At night, photosynthesis stops while respiration continues.
Therefore:
Afternoon DO may be high.
But:
Early-morning DO may be much lower.
This is one reason an afternoon-only testing schedule can miss important oxygen conditions.
7. Cloudy or Rainy Weather
Weather can influence pond conditions.
Several cloudy days may reduce photosynthetic oxygen production.
Heavy rain can also change temperature and water chemistry.
After significant weather changes, additional water-quality measurements may be useful.
Why Is DO Often Lowest in the Early Morning?
During daylight:
Photosynthesis → oxygen contribution
During the night:
Photosynthesis stops
while:
Fish + microorganisms + plants continue respiration
As oxygen continues to be consumed overnight, DO may progressively decrease.
This is why early-morning DO measurement can be particularly valuable in pond aquaculture.
If you measure only at 3 PM, you may completely miss the lowest DO period.
Possible Signs That Require Immediate Water Testing
Behaviour alone cannot diagnose a water-quality problem, but unusual observations should trigger testing.
Examples may include:
Fish gathering near the surface
Fish gathering near water inflow
Reduced feeding response
Unusual swimming behaviour
Sudden changes in activity
Problems occurring particularly in the early morning
Do not automatically assume that every behavioural change is caused by low oxygen.
Instead, measure several relevant parameters.
Measure More Than Dissolved Oxygen
Suppose fish are behaving unusually.
The DO reading is acceptable.
The investigation should not necessarily stop.
Check:
Dissolved Oxygen
pH
Ammonia Nitrogen
Nitrite
Temperature
Water-quality problems can involve multiple interacting parameters.
This is where a multi-parameter instrument becomes useful.
Smart Sensor AR8407 for Fish Pond DO Testing
The Smart Sensor AR8407 Water Quality Meter measures:
Dissolved Oxygen
0–30.0 mg/L
pH
3.5–11.0
Ammonia Nitrogen
0–1.00 mg/L
Nitrite
0–1.00 mg/L
Temperature
0–50°C
Instead of using the AR8407 simply as a DO meter, fish farmers can use it as a broader aquaculture water-quality monitoring instrument.
3.5 m DO Probe Cable
Pond measurements often require more flexibility than laboratory measurements.
The AR8407 DO probe is equipped with an approximately:
3.5-metre cable
This allows users to position the probe farther from the immediate pond edge or into tanks and other difficult-to-reach measurement points.
Don't Test Only One Spot
DO can vary within the same pond.
Possible differences may occur between:
Aerated area vs non-aerated area
Surface vs deeper water
Feeding zone vs other areas
Inlet vs outlet
For larger ponds, establish several consistent measurement locations.
For example:
Point A – Near aerator
Point B – Feeding area
Point C – Away from aerator
Point D – Pond outlet
Repeated measurements from consistent points make comparison much more meaningful.
Build a DO Trend Instead of Collecting Random Numbers
A professional monitoring routine should create comparable data.
For example:
TimeDOTemperaturepH6:00 AM___ mg/L___ °C___12:00 PM___ mg/L___ °C___4:00 PM___ mg/L___ °C___
Repeat the measurements over several days.
Now you can begin to see:
Daily DO variation
Temperature relationship
Morning low points
Unusual changes
Effect of aeration
This is more useful than taking random readings only when problems occur.
What Should You Check When DO Suddenly Drops?
If dissolved oxygen falls unexpectedly, investigate systematically.
1. Check the aerator
Is it operating normally?
2. Check water temperature
Has temperature increased significantly?
3. Review feeding
Has feed quantity recently increased?
4. Review stocking
Has fish biomass increased?
5. Look at organic loading
Is waste or sludge accumulating?
6. Consider weather
Has there been heavy rain or prolonged cloudy weather?
7. Check other water parameters
What are the pH, ammonia and nitrite readings?
The objective is not simply to detect low DO.
The objective is to understand why the water condition changed.
DO Meter vs Visual Observation
Experienced fish farmers can notice changes in fish behaviour.
That experience is valuable.
But visual observation and measurement serve different purposes.
Observation tells you:
“Something may be changing.”
A meter tells you:
“This is the measured water condition.”
The strongest approach is to use both.
Who Should Monitor Fish Pond DO?
DO monitoring can be relevant for:
Tilapia farms
Catfish farms
Freshwater fish farms
Shrimp farms
Prawn farms
Hatcheries
Aquaculture tanks
Recirculating aquaculture systems
Aquaculture research
Fisheries projects
Pond management
Looking for a Fish Pond DO Meter in Malaysia?
MTM Precision supplies water-quality testing instruments for aquaculture, environmental, agricultural and industrial applications in Malaysia.
Our range covers:
Dissolved Oxygen | pH | Ammonia | Nitrite | EC | TDS | Salinity | Turbidity | Multi-Parameter Water Quality Testing
For users who want to measure:
DO + pH + Ammonia Nitrogen + Nitrite + Temperature
the Smart Sensor AR8407 is one multi-parameter option to consider.
Tell us:
What type of pond are you testing?
Freshwater or brackish water?
Which parameters do you need?
How deep is the measurement point?
MTM Precision can help you compare suitable water-quality instruments.
Contact MTM Precision
MTM Precision Sdn Bhd
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: 016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
Supplying water-quality testing instruments across Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sarawak and Sabah.
09 Sep 2026