TWA vs STEL on a Gas Detector OTYWELL G40S Exposure Alarms Explained Malaysia

TWA vs STEL on a Gas Detector OTYWELL G40S Exposure Alarms Explained Malaysia A portable gas detector may show several types of alarms, including low alarm, high alarm, TWA and STEL. Low and high alarms warn when the current gas concentration reaches a programmed level. TWA and STEL serve a different purpose: they help assess a worker’s exposure over time. The OTYWELL G40S portable multi-gas detector supports: Low gas alarm High gas alarm TWA alarm STEL alarm Sound, light and vibration warning Fall alarm Measurement and alarm records Understanding these functions is essential when the detector is used for toxic gases such as carbon monoxide and hydrogen sulphide. What Does TWA Mean? TWA means Time-Weighted Average. It represents the average gas exposure calculated over a defined time period. Instead of looking only at the concentration displayed at one moment, the TWA function considers how the concentration changes over time. A simplified example: Time PeriodCO ReadingFirst period5 ppmSecond period15 ppmThird period40 ppmFourth period10 ppm The worker was not exposed to one fixed concentration throughout the period. A time-weighted calculation provides a more representative indication of cumulative exposure. The applicable averaging period and exposure limit depend on the gas, workplace requirements and safety programme. The detector settings must be reviewed by competent safety personnel. Do not assume that the factory-default TWA value is correct for every workplace. What Does STEL Mean? STEL means Short-Term Exposure Limit. It addresses shorter periods of elevated exposure. A worker may have an acceptable average exposure over an entire shift but still experience a brief concentration high enough to require attention. For example: Most of the shift: low HS reading During sludge disturbance: sudden elevated HS After ventilation: reading decreases again The full-shift average may not clearly represent the short exposure. The STEL function helps identify this type of event. The exact averaging time and permitted value must follow the applicable occupational exposure requirement and site procedure. TWA vs STEL: What Is the Difference? ItemTWASTELFull termTime-Weighted AverageShort-Term Exposure LimitMain purposeAssess average exposure over a longer defined periodAssess elevated exposure over a shorter defined periodResponds toCumulative exposureShort-duration concentration increaseTypical useShift exposure assessmentBrief exposure eventsCommonly relevant toToxic gasesToxic gasesSame as high alarm?NoNoRequires correct detector time and operating history?YesYes TWA and STEL are related, but one cannot replace the other. Low Alarm vs High Alarm vs TWA vs STEL A gas detector can produce different alarms because gas hazards can develop in different ways. Low Alarm The low alarm is usually the first immediate concentration warning. It may tell the worker that conditions are deteriorating and action is required according to the site procedure. High Alarm The high alarm indicates that the current concentration has reached a higher programmed threshold. The user should follow the worksite evacuation and emergency procedure immediately. TWA Alarm A TWA alarm indicates that the calculated average exposure over the configured period has reached its limit. It may activate even when the current reading is lower than the high alarm. STEL Alarm A STEL alarm indicates that the calculated short-term exposure has reached its configured limit. It may identify a significant exposure period that does not remain long enough to trigger a TWA alarm. Example: Carbon Monoxide Exposure Consider a maintenance worker entering several mechanical rooms during one shift. The CO reading may change as follows: 0 ppm in the open area 10 ppm in one room 25 ppm near operating equipment 60 ppm for a short period near an exhaust leak 5 ppm after leaving the area The G40S may evaluate different aspects of this exposure: Current concentration for low or high alarm Short-duration exposure for STEL Accumulated average exposure for TWA Peak reading for incident review The response depends on the programmed limits and the organisation’s procedure. A detector alarm should not be dismissed merely because the current reading later returns to zero. Example: Hydrogen Sulphide in Wastewater Work A wastewater technician may initially see a low HS reading. When the worker opens a chamber or disturbs sludge, the concentration can rise quickly and then decrease after ventilation. This situation may involve: Immediate low alarm Immediate high alarm STEL exposure Increased TWA value Recorded peak concentration The detector record can help safety personnel understand whether the event was a brief spike, sustained exposure or part of a repeated pattern. Are TWA and STEL Used for Oxygen and LEL? TWA and STEL are mainly associated with exposure to toxic substances. Oxygen and combustible-gas hazards are normally managed through immediate concentration alarms and site-specific procedures. For example: Low oxygen requires immediate attention. Oxygen enrichment can increase fire risk. Rising LEL indicates increasing combustible-gas risk. A dangerous combustible atmosphere should not be assessed using a shift-average approach. The exact alarm behaviour of the G40S depends on the installed sensors and firmware configuration. Why Can a TWA Alarm Activate When the Current Reading Is Low? A TWA value includes earlier exposure during the calculation period. Suppose the worker experienced a high concentration earlier and later moved into cleaner air. The current reading may fall, but the accumulated average exposure can remain elevated. This is not necessarily an instrument fault. The responsible person should review: Current reading TWA value STEL value Peak reading Alarm history Work location Exposure duration Detector operating time Resetting or switching off the detector may affect its exposure calculation. Users must follow the approved procedure rather than clearing an alarm simply to continue working. Why Can a STEL Alarm Activate Below the High Alarm? The STEL alarm and high alarm may use different thresholds and calculation methods. A high alarm normally responds to the current concentration. STEL evaluates exposure over a short defined period. Therefore, a concentration that remains below the immediate high-alarm setting may still produce a STEL alarm when it continues for long enough. This is one reason why users need training on every alarm symbol and sound pattern. Why Should Alarm Settings Be Checked? Factory-default settings may not match: The target gas Malaysian workplace requirements Customer safety standards Site-specific exposure limits Company procedures Project requirements International client requirements Before the detector is issued, confirm: Gas name Measuring range Units Low alarm High alarm TWA limit STEL limit Averaging period Alarm latching behaviour Reset procedure Only authorised personnel should change safety-critical alarm settings. What Happens When the Detector Is Switched Off? TWA and STEL calculations depend on the detector’s operating logic. Switching the instrument off, changing the user, resetting exposure data or starting a new session may affect the stored calculation. Before using one detector for several workers, confirm: When TWA resets When STEL resets Whether exposure history is retained How a new worker session is created Whether records identify the assigned user What happens after charging or power-off Whether previous alarms remain in memory A detector should not be passed between workers without understanding how its exposure records are managed. Why Detector Assignment Matters If several workers share one detector during the same shift, the displayed TWA may no longer represent one individual’s exposure correctly. For meaningful exposure monitoring, the organisation should record: Detector serial number Assigned worker Start time End time Work location Gas configuration Alarm settings Calibration status A detector used as personal protective monitoring equipment should remain associated with the correct wearer according to the site procedure. How G40S Data Logging Supports Exposure Review The G40S can store measurement and alarm information for later transfer to a computer. The records may help answer: Which gas caused the alarm? When did it occur? What was the peak concentration? How long did the reading remain elevated? Did the TWA or STEL alarm activate? Where was the employee working? Was ventilation operating? Did similar events occur previously? To make this information useful, the detector’s date and time must be correct. The customer should also confirm the supplied software, connection method and export format before purchase. Does Data Logging Replace Exposure Assessment? No. Portable detector records can support an investigation, but they do not automatically replace: Formal workplace exposure monitoring Industrial hygiene assessment Area sampling Personal sampling using an approved method Risk assessment Medical surveillance Regulatory documentation The G40S is an alarm and monitoring instrument. Whether its recorded data is suitable for a specific compliance purpose must be determined by the responsible occupational safety or hygiene professional. TWA and STEL Depend on a Working Sensor Exposure calculations are meaningful only when the gas sensor is functioning correctly. Before use: Inspect the detector Check the sensor openings Confirm the gas configuration Verify calibration status Perform the required bump test Review alarm settings Check battery condition Confirm the date and time A detector may display a TWA value while its sensor is overdue for calibration. The presence of a calculation does not guarantee measurement accuracy. Calibration vs Alarm Setting Calibration and alarm settings are different. Calibration Calibration adjusts the detector’s measurement response against known reference gas. Alarm Setting Alarm settings determine when the detector warns the user. Changing an alarm threshold does not calibrate the sensor. Calibrating the sensor does not automatically confirm that the alarm thresholds match the customer’s workplace requirements. Both must be reviewed. What Should a Worker Do When TWA or STEL Alarms? The worker should follow the organisation’s established procedure. Depending on the worksite, this may include: Stop work. Leave the affected area. Notify the supervisor or standby person. Record the gas and alarm type. Review the work activity and ventilation. Prevent uncontrolled re-entry. Review the worker’s potential exposure. Seek appropriate assessment when required. Do not silence the alarm and continue working merely because there is no immediate smell or discomfort. Common TWA and STEL Mistakes Treating TWA as the Current Reading TWA represents an average calculation, not only the concentration shown at that moment. Treating STEL as the High Alarm STEL and the immediate high alarm can have different values and logic. Using Factory Defaults Without Review Default settings may not match the workplace requirement. Sharing One Detector Without Reset Management Exposure history may be incorrectly associated with another worker. Switching Off the Detector to Clear an Alarm This may erase or interrupt exposure calculations without controlling the hazard. Ignoring the Detector Clock Incorrect date and time reduce the value of downloaded alarm records. Confusing Data Logging with Calibration Stored measurements are not proof that the sensor was accurate. Questions to Ask Before Buying a Gas Detector When TWA and STEL are required, ask: Which sensors support TWA and STEL? Can the values be adjusted? Who can access the settings? What averaging periods are used? When do the calculations reset? Are TWA and STEL alarms stored? Can the records be downloaded? Is software included? Can data be exported? Does the detector identify different users? What happens when the battery is switched off? Can settings be protected from unauthorised changes? Are the alarm sounds or symbols different? What calibration equipment is required? These questions help determine whether the detector supports the customer’s actual exposure-management process. G40S Functions at a Glance FunctionPurposeLow alarmEarly immediate concentration warningHigh alarmHigher immediate concentration warningTWA alarmLonger-period average exposure warningSTEL alarmShort-period exposure warningPeak recordIdentifies highest measured concentrationData storageRetains measurements and alarm eventsFall alarmWarns of possible wearer fall or incapacitySound-light-vibrationAlerts the wearer in different environmentsComputer uploadSupports later record reviewOptional wireless functionsSupports connected applications according to configuration Is the OTYWELL G40S Right for Your Application? The G40S may be suitable when the customer requires: LEL, O, CO and HS monitoring Immediate high and low alarms TWA and STEL warnings Exposure and alarm records Fall detection Data transfer Optional wireless connectivity The correct sensor combination, measuring range and alarm values must be confirmed before purchase. OTYWELL G40S Supplier Malaysia MTM Precision supplies portable gas detectors for industrial safety, confined-space, wastewater, tank-inspection and marine applications. Customers can contact us to discuss: Required gases Measuring ranges TWA and STEL requirements Alarm settings Data-logging requirements Fall alarm Wireless configuration Calibration accessories Replacement sensors Required documentation Contact MTM Precision MTM Precision Sdn Bhd Website: www.mtmpre.com.my Email: mtmpre@yahoo.com WhatsApp: 016-660 7346 Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia. Supply and support enquiries are welcome from Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sarawak, Sabah and throughout Malaysia.

13 Sep 2026