Portable Gas Detector Low High STEL and TWA Alarms Explained Malaysia
Portable Gas Detector Low High STEL and TWA Alarms Explained Malaysia
Portable multi-gas detectors such as the Smart Sensor ST8904 may support four important alarm types:
-
Low alarm
-
High alarm
-
STEL alarm
-
TWA alarm
These alarms do not mean the same thing.
Low and High alarms respond mainly to the current gas concentration, while STEL and TWA relate to a worker’s exposure over time.
Understanding the difference helps safety personnel configure and use the detector correctly.
What Is a Low Alarm?
The Low alarm is normally the first warning that a gas concentration has reached a configured level.
For toxic or combustible gas, it may indicate that the reading has increased to the first alarm threshold.
For oxygen, the alarm logic may also respond when oxygen drops below or rises above configured limits, depending on the detector.
A Low alarm should not be treated as permission to continue working until the High alarm activates.
The required response should be defined in the company’s safety and emergency procedure.
What Is a High Alarm?
The High alarm indicates that the reading has reached a more serious configured threshold.
It may use a different:
-
Audible pattern
-
Warning-light sequence
-
Display indication
-
Vibration pattern
When a High alarm occurs, personnel should follow the site’s emergency procedure immediately.
Do not silence the detector and continue working simply because no gas can be seen or smelled.
What Is STEL?
STEL means Short-Term Exposure Limit.
It relates to a worker’s average exposure over a specified short period rather than only the current instantaneous reading.
A toxic-gas concentration may remain below the High alarm but still produce a STEL alarm when exposure is high enough over the short averaging period.
STEL is mainly relevant to toxic gases such as:
-
Carbon monoxide
-
Hydrogen sulphide
-
Other supported toxic-gas sensors
The applicable averaging period and limit must follow the relevant occupational-safety requirements and workplace procedure.
What Is TWA?
TWA means Time-Weighted Average.
It represents average exposure across a longer work period.
A lower gas concentration that continues for several hours can contribute to a TWA alarm, even if the reading never reaches the High instantaneous-alarm level.
TWA helps address cumulative exposure during the work period.
The detector must remain operating and assigned correctly for the exposure calculation to be meaningful.
Low vs High vs STEL vs TWA
| Alarm | What it generally represents | Main purpose |
|---|---|---|
| Low | First instantaneous warning level | Early warning |
| High | Higher instantaneous warning level | Urgent hazard warning |
| STEL | Short-period average exposure | Controls short-term toxic-gas exposure |
| TWA | Longer-period average exposure | Controls cumulative work-period exposure |
The exact operation can vary according to detector design, gas channel and configuration.
Example of How the Alarms Differ
Imagine that a worker enters an area containing carbon monoxide.
Situation 1: Sudden high concentration
The reading increases rapidly. The detector may activate its Low alarm followed by its High alarm.
Situation 2: Moderate short-term exposure
The reading remains elevated for a shorter period. It may contribute to a STEL alarm even if the High threshold is not reached.
Situation 3: Lower but prolonged exposure
The concentration remains elevated for several hours. The accumulated exposure may trigger the TWA alarm.
This is why toxic-gas safety cannot be evaluated using only the highest instantaneous reading.
Do STEL and TWA Apply to Oxygen?
STEL and TWA are generally used for occupational exposure to toxic substances.
Oxygen is usually monitored using low and high concentration limits for:
-
Oxygen deficiency
-
Oxygen enrichment
The alarm configuration depends on the detector and site procedure.
Does TWA Apply to Combustible Gas?
Combustible gas is normally managed through %LEL alarm thresholds because the immediate concern is fire or explosion risk.
TWA is primarily associated with exposure to toxic gases rather than combustible-gas explosivity.
A combustible-gas reading should not be ignored simply because it does not produce a TWA value.
Why Are Alarm Settings Different Between Worksites?
Alarm settings may depend on:
-
Applicable occupational-exposure limits
-
Site risk assessment
-
Customer or project requirements
-
Gas type
-
Work duration
-
Emergency plan
-
Detector capability
-
Company policy
-
Local regulatory requirements
A setting used by one factory or country may not automatically be suitable for another workplace.
Can You Copy Alarm Values from the Internet?
Do not change alarm settings based only on an online chart, marketplace listing or another company’s detector.
Before setting alarm values, confirm:
-
Target gas
-
Measuring unit
-
Applicable exposure standard
-
Averaging period
-
Site procedure
-
Customer requirements
-
Detector range and resolution
-
Who is authorised to make changes
Incorrect alarm settings can create either excessive nuisance alarms or delayed warning of a genuine hazard.
Should Users Increase the Alarm Limit to Stop Frequent Alarms?
No.
Frequent alarms may indicate:
-
Actual gas exposure
-
Poor ventilation
-
Process leakage
-
Incorrect alarm configuration
-
Sensor drift
-
Chemical interference
-
Incorrect zeroing
-
Calibration problem
Investigate the cause instead of simply raising the alarm threshold.
Changing a safety limit without authorisation could expose workers to greater risk.
What Should You Do When an Alarm Activates?
Follow the organisation’s emergency procedure, which may include:
-
Stop work.
-
Leave the affected area.
-
Warn nearby personnel.
-
Report the alarm to the supervisor.
-
Prevent unprotected entry.
-
Investigate from a safe location.
-
Ventilate where authorised.
-
Retest before returning.
The correct action should be established during training, not decided only after the alarm occurs.
Why Does the Alarm Remain Active After Leaving the Area?
Possible reasons include:
-
Gas remains around the sensor
-
Sensor requires recovery time
-
The alarm is latched
-
STEL or TWA exposure remains recorded
-
The detector has not reached its reset condition
-
Fresh air is not actually clean
-
Sensor drift or contamination is present
Move to a confirmed safe atmosphere and follow the detector’s operating procedure.
Do not repeatedly switch the detector off and on merely to clear an exposure alarm.
What Happens If the Detector Is Shared Between Workers?
STEL and TWA calculations relate to exposure accumulated while the detector is operating.
If several workers share one detector during the same work period:
-
The exposure history may not represent one individual
-
A new worker may inherit the previous exposure data
-
Records may become confusing
-
Detector assignment may be unclear
Where exposure tracking is important, manage detector assignment and data according to the company procedure.
When Should STEL and TWA Be Reset?
Resetting exposure values should follow:
-
Manufacturer instructions
-
Shift procedure
-
Detector-assignment policy
-
Workplace exposure programme
-
Authorised personnel requirements
Do not reset values simply to remove an alarm without documenting and investigating the exposure.
Smart Sensor ST8904 Alarm Functions
The Smart Sensor ST8904 supports monitoring functions that include:
-
Gas-monitoring display
-
Low alarm
-
High alarm
-
STEL display or alarm
-
TWA display or alarm
-
Peak-value viewing
-
Audible warning
-
Visual warning
-
Vibration warning
Its standard gas configuration is:
-
O₂: 0–30% VOL
-
CO: 0–999 ppm
-
H₂S: 0–500 ppm
-
Combustible gas: 0–100% LEL
Confirm the exact settings and required procedure before deployment.
Bump Test the Alarm Functions
A bump test should confirm more than the displayed gas value.
Check that:
-
The correct gas channel responds
-
The audible alarm is strong
-
The warning light operates
-
The vibration alarm activates
-
The displayed warning is understandable
-
The detector recovers correctly in fresh air
If an alarm component does not work, the detector should not be relied upon for safety-critical monitoring.
Need Help Understanding Gas-Detector Settings?
MTM Precision supplies the Smart Sensor ST8904 four-in-one gas detector and other portable gas-detection options in Malaysia.
Customers can contact us regarding:
-
Product selection
-
Gas configuration
-
Alarm-function questions
-
Bump-test requirements
-
Calibration enquiries
-
Abnormal readings
-
Diffusion versus pump selection
-
Alternative single-gas and multi-gas detectors
Final alarm values should be approved according to the applicable workplace-safety requirements and site procedure.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Office: +603-8080 7172
Desmond: +6019-220 7346
Fifi Ng: +6016-660 7346
WhatsApp: +6019-220 7346
Email: enquiry@mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Serving customers throughout Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
16 Sep 2026