Low Dissolved Oxygen in Fish Ponds Testing with Qiwei JPB-70A Malaysia

Low Dissolved Oxygen in Fish Ponds Testing with Qiwei JPB-70A Malaysia Fish swimming near the water surface, reduced feeding activity and sudden mortality may indicate low dissolved oxygen in a fish pond. However, these symptoms can also be caused by water temperature, disease, ammonia or poor water quality. The Qiwei JPB-70A Portable Dissolved Oxygen Meter allows fish farmers and aquaculture operators to measure the actual dissolved oxygen concentration instead of relying only on visual observations. Common Signs of Low Dissolved Oxygen Possible warning signs include: Fish gathering near the surface Fish gasping or opening their mouths frequently Fish concentrating near water inlets Reduced feeding activity Slow fish movement Shrimp moving toward shallow areas Unusual odour from pond water Sudden mortality during early morning Fish gathering around operating aerators These warning signs require immediate investigation. A DO meter can help determine whether insufficient oxygen is contributing to the problem. Why Does Pond Oxygen Drop? 1. High Stocking Density More fish means greater oxygen consumption. A pond that previously maintained acceptable oxygen levels may become unstable as the fish grow. 2. Excess Feed and Organic Waste Uneaten feed, fish waste and decaying organic matter consume oxygen during decomposition. Poor pond-bottom conditions can therefore reduce available oxygen. 3. High Water Temperature Warm water holds less dissolved oxygen than cooler water. At the same time, fish and microorganisms may consume oxygen more rapidly under warmer conditions. This makes regular DO monitoring particularly important in Malaysia’s hot climate. 4. Cloudy or Rainy Weather Extended cloudy weather reduces photosynthesis by algae and aquatic plants. Less oxygen is produced during the day, while oxygen consumption continues throughout the night. 5. Excessive Algae A pond may appear healthy and green during the day but experience a significant oxygen drop before sunrise. Algae produce oxygen in daylight but consume oxygen at night. An algae die-off can create an even greater problem because decomposing algae consume large amounts of oxygen. 6. Insufficient Aeration The number, position or operating time of aerators may be inadequate for the pond size and fish population. A damaged or poorly maintained aerator can also reduce oxygen transfer. When Should Dissolved Oxygen Be Measured? For routine aquaculture monitoring, test at consistent times so that results can be compared properly. Useful measurement times include: Before sunrise: Usually the most critical period During early morning feeding Late afternoon: Helps show daytime oxygen production After heavy rain During extended cloudy weather After adding a large quantity of feed When fish behave abnormally Before and after operating aerators An afternoon reading alone may create a false sense of security because dissolved oxygen can be considerably lower the following morning. How to Test with the Qiwei JPB-70A Check that the probe membrane is clean and undamaged. Switch on the instrument and allow the electrode to prepare for measurement. Immerse the probe at the required location and depth. Move the probe gently or ensure water flows across its membrane. Wait until the reading becomes stable. Record the dissolved oxygen value, water temperature, location and time. Repeat the measurement at several pond locations. Rinse the electrode with clean water after use. The JPB-70A has a dissolved oxygen range of 0.019.9 mg/L, a 0.1 mg/L resolution and automatic temperature compensation for routine field measurement. Do Not Test at Only One Location Dissolved oxygen can vary considerably across the same pond. Test at locations such as: Near the aerator Away from the aerator Close to the water inlet Near the centre of the pond At the surface At a greater depth Near areas with accumulated organic waste A good oxygen reading beside an aerator does not necessarily mean that the entire pond has sufficient oxygen. What Should You Do If DO Is Low? If the measurement confirms low dissolved oxygen: Start or increase mechanical aeration Reduce or temporarily stop feeding Check whether aerators are operating correctly Improve water circulation Remove excessive organic waste where practical Inspect water inlets and outlets Retest the pond after corrective action Continue monitoring until readings stabilise The correct response depends on the species, stocking density, water temperature and farm-management system. The DO meter provides objective data to support the decision. Avoid These Common Measurement Mistakes Measuring Only After Fish Show Symptoms By the time fish begin gasping, the oxygen level may already be seriously low. Routine monitoring allows earlier intervention. Holding the Probe in Completely Still Water A polarographic dissolved oxygen electrode requires water movement across the membrane. Gently move the probe during testing. Ignoring Probe Maintenance A damaged membrane, depleted electrolyte or trapped air bubble may cause unstable or inaccurate readings. Comparing Readings Taken at Different Times A reading taken at 5:00 AM should not be directly compared with one taken at 4:00 PM without considering the natural daily oxygen cycle. Assuming More Decimal Places Mean Better Accuracy The JPB-70A displays readings to 0.1 mg/L, which is suitable for routine field checks. Measurement accuracy depends on the electrode condition, calibration and correct operating techniquenot only the number of digits on the display. Is the Qiwei JPB-70A Suitable for Your Pond? The Qiwei JPB-70A is suitable for: Fish farmers Shrimp-farm operators Hatcheries Koi-pond operators Aquaculture consultants Agricultural colleges Routine wastewater checks General water-quality field testing It provides a practical entry-level solution for users who need portable dissolved oxygen measurements without advanced data-logging functions. Qiwei JPB-70A Stock in Malaysia The Qiwei JPB-70A Portable Dissolved Oxygen Meter is available from MTM Precision inMalaysia. Customers may contact us for current stock, pricing, accessories and advice on dissolved oxygen measurement. We serve customers throughout Selangor, Kuala Lumpur, Johor, Penang, Perak, Pahang, Kedah, Kelantan, Terengganu, Sabah and Sarawak. Contact MTM Precision MTM Precision Sdn. Bhd. (744811-A) Telephone: +603-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my Website: www.mtmpre.com.my Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia. Contact MTM Precision for the Qiwei JPB-70A price, availability and dissolved oxygen measurement advice in Malaysia.

18 Sep 2026