How to Compare Two Solar Panels Using FUZRR FR705 Malaysia

How to Compare Two Solar Panels Using FUZRR FR705 Malaysia

 

When two solar panels have the same rated power, should they always produce exactly the same output?

 

Not necessarily.

 

Even identical photovoltaic (PV) panels can show different field performance because of sunlight intensity, temperature, shading, dirt, ageing, installation conditions, or panel condition.

 

For solar installers and maintenance technicians, comparing two panels under similar conditions is one practical way to identify a potentially underperforming module.

 

The FUZRR FR705 Solar MPPT Power Tester can be used to compare solar panel operating performance directly on-site.

 

Why Compare Solar Panels?

 

Comparative testing can be useful when:

 

One panel is suspected of underperforming

 

New panels arrive at a project site

 

A customer reports reduced solar generation

 

Used solar panels are being inspected

 

Several identical panels need to be checked

 

Maintenance is being performed on an existing PV system

 

Instead of looking only at the rated wattage printed on the label, technicians can compare actual field measurements.

 

Step 1: Confirm the Panels Are Comparable

 

Before comparing results, check whether both panels have the same:

 

Model

 

Rated power

 

Voltage specifications

 

Current specifications

 

Cell technology

 

Comparing a 450W panel directly with a 550W panel without considering their specifications would not provide a meaningful result.

 

Step 2: Inspect Both Panels

 

Check both modules for:

 

Dust

 

Bird droppings

 

Cracked glass

 

Damaged cells

 

Loose connectors

 

Cable damage

 

Junction box problems

 

Partial shading

 

If one panel is dirty while the other is clean, the comparison will already be affected.

 

Step 3: Use Similar Sunlight Conditions

 

This is one of the most important parts of comparative solar testing.

 

Solar panel output can change quickly when sunlight changes.

 

Whenever possible:

 

Test both panels close together in time

 

Use the same orientation

 

Use a similar tilt angle

 

Avoid moving cloud conditions

 

Keep both panels free from shading

 

The objective is to reduce environmental differences as much as practical.

 

Step 4: Test the First Panel

 

Connect the FUZRR FR705 Solar MPPT Power Tester according to the instrument operating procedure.

 

Before connection, confirm that the PV panel is within the permitted electrical input limits of the tester.

 

Record the relevant readings, such as:

 

Maximum Power

 

Operating Voltage

 

Operating Current

 

Also record the time and weather conditions if the comparison is important.

 

Step 5: Test the Second Panel

 

Test the second panel immediately afterwards under conditions that are as similar as possible.

 

Record the same parameters.

 

You can then compare the results.

 

Example Comparison

 

Imagine two identical solar panels are tested under similar sunlight conditions.

 

ParameterPanel APanel BMaximum Power420W415WOperating VoltageSimilarSimilarOperating CurrentSimilarSimilar

 

A small difference may be normal because field conditions are never perfectly identical.

 

Now consider another example:

 

ParameterPanel APanel BMaximum Power420W290WOperating VoltageNormalSimilarOperating CurrentNormalSignificantly Lower

 

The larger difference suggests that Panel B deserves further investigation.

 

It does not automatically prove that Panel B is defective.

 

The technician should first rule out differences in sunlight, temperature, shading, dirt, connectors and test setup.

 

What Can Cause One Panel to Produce Less Power?

 

Possible reasons include:

 

Partial Shading

 

A nearby structure, cable, tree branch or other object may shade part of the module.

 

Dirt

 

Dust and contamination reduce the sunlight reaching the solar cells.

 

Higher Panel Temperature

 

A hotter panel can produce less power than a cooler panel.

 

Connector Problems

 

Loose or damaged connectors can affect electrical performance.

 

Panel Ageing

 

Older panels may gradually produce less power.

 

Internal Damage

 

Cell damage, bypass diode problems or other internal faults may affect performance.

 

Further testing may be required to determine the exact cause.

 

Why Voltage Alone Is Not Enough

 

Suppose both panels show similar open-circuit voltage.

 

Does that mean both panels are equally healthy?

 

No.

 

A panel can still show reasonable voltage while its ability to deliver current and power under load is reduced.

 

This is why evaluating operating power can provide additional information during troubleshooting.

 

Why Use the FUZRR FR705?

 

The FR705 is designed as a portable solar MPPT power testing instrument.

 

Key features include:

 

Manual / Auto Mode

 

Large LCD

 

Compact portable design

 

Reverse connection protection

 

Over-temperature protection

 

Over-voltage protection

 

Over-current protection

 

Overload protection

 

This makes it useful for technicians who need quick solar panel comparisons in the field.

 

Practical Applications in Malaysia

 

Comparative PV testing can be useful for:

 

Residential rooftop solar systems

 

Commercial rooftop PV

 

Factory solar installations

 

Solar maintenance contractors

 

Solar panel incoming inspection

 

Off-grid systems

 

Solar street lights

 

Solar CCTV installations

 

Solar water pumps

 

Technical training

 

Important Testing Reminder

 

Solar panel output depends strongly on environmental conditions.

 

A field measurement should therefore be interpreted together with factors such as:

 

Solar irradiance

 

Panel temperature

 

Orientation

 

Tilt angle

 

Weather

 

Shading

 

Do not declare a solar panel defective based on a single power reading alone.

 

Repeat the test under comparable conditions and perform additional diagnostic testing where necessary.

 

Looking for a Solar Panel Tester in Malaysia?

 

MTM Precision supplies testing and measurement instruments for solar installers, electrical contractors, maintenance companies, facility teams and engineering professionals throughout Malaysia.

 

The FUZRR FR705 Solar MPPT Power Tester provides a portable solution for solar panel performance checks, comparisons and preliminary troubleshooting.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Contact MTM Precision for the FUZRR FR705 Solar MPPT Power Tester in Malaysia and other professional solar and electrical testing solutions.


 

19 Sep 2026