mG, uT, V/m and mW/m2 Explained - How to Read TENMARS TM-290 EMF Measurements Malaysia

mG, uT, V/m and mW/m2 Explained - How to Read TENMARS TM-290 EMF Measurements Malaysia

 

When using an EMF meter, one of the first questions is often:

 

What do mG, uT, V/m and mW/m2 actually mean?

 

These units do not all measure the same thing.

 

The TENMARS TM-290 Multi-Field EMF Meter can measure low-frequency magnetic fields, low-frequency electric fields and RF electromagnetic fields.

 

Because these are different physical quantities, different measurement units are used.

 

Understanding these units is important before comparing, recording or interpreting EMF measurements.

 

What Does mG Mean?

 

mG means milligauss.

 

It is a unit used for magnetic-field measurement.

 

The TENMARS TM-290 provides low-frequency magnetic-field ranges of:

 

20 mG

 

200 mG

 

2000 mG

 

The magnetic-field measurement operates at 50/60 Hz.

 

This function may be useful when investigating areas around:

 

Electrical panels

 

Transformers

 

Motors

 

Pumps

 

UPS systems

 

Power supplies

 

Electrical rooms

 

Industrial machinery

 

What Does uT Mean?

 

uT means microtesla.

 

Microtesla is another unit used to express magnetic flux density.

 

The TM-290 provides magnetic-field ranges of:

 

2 uT

 

20 uT

 

200 uT

 

Therefore, both mG and uT may be used when recording the TM-290's low-frequency magnetic-field measurements.

 

How Do You Convert mG to uT?

 

A useful conversion is:

 

1 uT = 10 mG

 

Therefore:

 

1 mG = 0.1 uT

 

Examples:

 

5 mG = 0.5 uT

 

10 mG = 1 uT

 

50 mG = 5 uT

 

100 mG = 10 uT

 

1000 mG = 100 uT

 

This is useful when comparing specifications, measurements or reports that use different magnetic-field units.

 

What Does V/m Mean?

 

V/m means volts per metre.

 

The TENMARS TM-290 uses V/m for low-frequency electric-field measurement.

 

Its electric-field measurement range is:

 

50 V/m to 2000 V/m

 

Frequency:

 

50/60 Hz

 

Electric-field measurement is different from magnetic-field measurement.

 

For example:

 

10 uT

 

and

 

10 V/m

 

are not equivalent readings.

 

One represents magnetic flux density, while the other represents electric-field strength.

 

What Does uW/m2 Mean?

 

uW/m2 means microwatts per square metre.

 

This is one of the power-density units used for RF electromagnetic field measurements.

 

The TENMARS TM-290 RF measurement range starts from:

 

0.2 uW/m2

 

The RF frequency range is:

 

50 MHz to 10 GHz

 

RF measurement may be useful when investigating compatible wireless and communication sources operating within the instrument's specified frequency range.

 

What Does mW/m2 Mean?

 

mW/m2 means milliwatts per square metre.

 

It is another RF power-density unit.

 

The relationship is:

 

1 mW/m2 = 1000 uW/m2

 

Examples:

 

0.5 mW/m2 = 500 uW/m2

 

1 mW/m2 = 1000 uW/m2

 

10 mW/m2 = 10,000 uW/m2

 

The TENMARS TM-290 RF measurement range extends up to:

 

554.6 mW/m2

 

What RF Units Can the TM-290 Display?

 

The TENMARS TM-290 supports several RF measurement units, including:

 

uW/m2

 

mW/m2

 

uW/cm2

 

mV/m

 

V/m

 

mA/m

 

dBm

 

This gives users flexibility when working with different measurement or reporting requirements.

 

However, always record the unit together with the number.

 

For example, writing:

 

Reading = 25

 

is incomplete.

 

Instead, record:

 

25 uW/m2

 

or:

 

25 V/m

 

depending on the selected measurement mode.

 

Why You Should Never Compare the Number Alone

 

Suppose one measurement shows:

 

5 uT

 

and another shows:

 

5 V/m

 

The number is the same, but they represent different physical quantities.

 

Likewise:

 

100 mG

 

cannot simply be compared numerically with:

 

100 uW/m2

 

Before interpreting a reading, ask:

 

What was measured?

 

What unit was used?

 

What frequency range was involved?

 

Where was the measurement taken?

 

Magnetic Field vs Electric Field vs RF

 

A simple way to understand the TENMARS TM-290 is:

 

Magnetic Field

 

Typical units:

 

mG or uT

 

TM-290 frequency:

 

50/60 Hz

 

Electric Field

 

Typical unit:

 

V/m

 

TM-290 frequency:

 

50/60 Hz

 

RF Field

 

Available units include:

 

uW/m2, mW/m2, uW/cm2, mV/m, V/m, mA/m and dBm

 

TM-290 RF frequency range:

 

50 MHz to 10 GHz

 

These are separate measurement functions.

 

Example: Electrical Panel

 

When checking an electrical panel, you may record:

 

Magnetic Field: 8 uT

 

and separately:

 

Electric Field: 250 V/m

 

These are two different measurements.

 

Do not add the values together or directly compare their numerical values.

 

Example: Wi-Fi Area

 

When investigating RF fields around compatible wireless equipment, you may select a power-density unit such as:

 

uW/m2

 

or:

 

mW/m2

 

Measurements can then be taken at several locations.

 

For example:

 

Near Access Point: XX uW/m2

 

Normal Workstation: XX uW/m2

 

Meeting Room: XX uW/m2

 

Reference Location: XX uW/m2

 

Recording the location provides much more useful information than recording only one RF value.

 

What About V/m for Both Electric Field and RF?

 

This is where users need to be careful.

 

V/m can be used to express electric-field strength, but the measurement mode and frequency range are important.

 

The TM-290 provides:

 

50/60 Hz low-frequency electric-field measurement

 

and a separate:

 

50 MHz to 10 GHz RF measurement function

 

Therefore, do not interpret the unit without checking which measurement mode is selected.

 

A good measurement record should always contain:

 

Measurement Mode + Reading + Unit + Location

 

A Better Way to Record EMF Measurements

 

For an electrical measurement:

 

Location: Electrical Room Panel A

 

Measurement: Magnetic Field

 

Reading: XX uT

 

Distance: XX cm or m

 

Equipment Condition: Operating

 

For an RF measurement:

 

Location: Office Access Point A

 

Measurement: RF Field

 

Reading: XX uW/m2

 

Distance: XX m

 

Equipment Condition: Operating

 

This makes future comparison easier.

 

Does a Higher Reading Automatically Mean Dangerous?

 

A displayed value should not be classified as safe or dangerous simply because the number appears high or low.

 

Interpretation depends on factors including:

 

Type of electromagnetic field

 

Frequency

 

Measurement unit

 

Measurement method

 

Measurement position

 

Exposure scenario

 

Applicable guideline or standard

 

If measurements are being performed for occupational or regulatory compliance, the appropriate exposure standard and measurement procedure should be followed.

 

The TM-290 provides measurement data. Interpretation should be based on the relevant requirement.

 

Why Understanding Units Matters Before Buying an EMF Meter

 

Before purchasing an EMF meter, identify what you actually need to measure.

 

If your requirement is:

 

50/60 Hz Magnetic Field

 

Look for mG or uT measurement capability.

 

If your requirement is:

 

50/60 Hz Electric Field

 

Look for V/m measurement capability.

 

If your requirement is:

 

RF Electromagnetic Field

 

Check the RF frequency range and supported measurement units.

 

The TENMARS TM-290 combines all three measurement categories in one handheld instrument.

 

TENMARS TM-290 EMF Meter Malaysia

 

The TENMARS TM-290 provides:

 

3-Axis Magnetic Field: 50/60 Hz

 

Electric Field: 50/60 Hz

 

RF Field: 50 MHz to 10 GHz

 

Its multi-field design makes it suitable for general EMF investigation around electrical equipment, factories, offices, commercial buildings, data centres and compatible RF sources.

 

For TENMARS TM-290 quotation, stock availability or technical enquiries in Malaysia, contact:

 

MTM Precision Sdn Bhd

 

Puchong Showroom & Service Centre

 

Tel: 03-8080 7172

 

WhatsApp: +6016-660 7346

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my

 

Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.


 

20 Sep 2026