Ultrasonic Thickness Gauge for Storage Tank Inspection Malaysia

Ultrasonic Thickness Gauge for Storage Tank Inspection Malaysia

 

Storage tanks used in factories and industrial facilities may experience corrosion and gradual wall-thickness loss during service.

 

The outside surface of a tank may still appear acceptable while deterioration is occurring elsewhere, including on surfaces that are difficult to inspect visually.

 

For suitable materials, an ultrasonic thickness gauge such as the UNI-T UT345A can help maintenance teams measure remaining tank-wall thickness from one accessible side without cutting the tank.

 

Why Measure Storage Tank Wall Thickness?

 

Tank walls and other suitable components can be affected by conditions such as:

 

Internal corrosion

 

External corrosion

 

Moisture

 

Chemical exposure

 

Environmental exposure

 

Coating deterioration

 

Long-term service

 

Localised material loss

 

Visual inspection can identify obvious surface problems, but it does not directly tell you the remaining metal thickness.

 

Ultrasonic thickness measurement provides quantitative thickness data at selected locations.

 

Can Tank Thickness Be Measured from the Outside?

 

For suitable materials and measurement conditions, yes.

 

An ultrasonic thickness gauge sends an ultrasonic pulse through the material and detects the returning echo.

 

Using the ultrasonic travel time and the appropriate material sound velocity, the instrument calculates thickness.

 

This allows measurement from one accessible surface.

 

For many maintenance applications, this means the tank wall can be checked externally without cutting a sample simply to obtain a thickness reading.

 

UNI-T UT345A for Tank Thickness Measurement

 

The UNI-T UT345A Ultrasonic Thickness Gauge is a portable instrument designed for material-thickness measurement.

 

Its measuring range is approximately:

 

1.00–300.00 mm

 

with adjustable sound velocity of approximately:

 

1000–9999 m/s.

 

Potential applications include suitable:

 

Storage tanks

 

Steel plates

 

Metal pipes

 

Fabricated components

 

Machinery

 

Industrial equipment

 

The actual suitability depends on material, geometry, surface condition and measurement requirements.

 

One Reading Is Not Enough

 

A large storage tank should not normally be represented by one randomly selected thickness measurement.

 

Corrosion can vary significantly across the surface.

 

For example:

 

Point A: 7.9 mm

Point B: 7.8 mm

Point C: 6.6 mm

Point D: 7.7 mm

 

If only Point A were measured, the lower reading at Point C would not be identified.

 

A systematic measurement plan provides more useful information.

 

Creating a Tank Thickness Measurement Grid

 

One practical approach is to divide an accessible area into repeatable measurement locations.

 

For example:

 

Location1234AA1A2A3A4BB1B2B3B4CC1C2C3C4DD1D2D3D4

 

The operator records the thickness at each defined location.

 

During a future inspection, measurements can be repeated at the same points.

 

This allows the maintenance team to compare changes over time, rather than collecting unrelated measurements during every inspection.

 

Example of Thickness Trending

 

Consider measurement point B3:

 

First inspection: 8.0 mm

Second inspection: 7.7 mm

Third inspection: 7.3 mm

 

The latest reading tells you the current measured thickness.

 

The historical readings provide additional evidence that thickness at this location has decreased over time.

 

This information can support further inspection and engineering evaluation.

 

Which Parts of a Tank Should Be Checked?

 

The appropriate measurement locations depend on the tank design, contents, deterioration mechanisms and applicable inspection programme.

 

Potential areas of interest may include:

 

Lower sections

 

Areas exposed to moisture

 

Locations showing external corrosion

 

Areas with coating damage

 

Weld-adjacent areas where required

 

Previously identified low-thickness locations

 

Sections exposed to aggressive service conditions

 

Measurement locations for critical equipment should be established according to the applicable inspection procedure rather than selected arbitrarily.

 

Surface Preparation Matters

 

A thickness gauge needs good ultrasonic contact with the test surface.

 

Before measuring, inspect the location for:

 

Loose rust

 

Scale

 

Dirt

 

Flaking paint

 

Rough corrosion

 

Surface contamination

 

Prepare the surface sufficiently to obtain reliable probe contact according to the applicable procedure.

 

Surface preparation should not unnecessarily remove sound base material.

 

Why Does UT345A Need Couplant?

 

Ultrasonic energy does not transfer efficiently through an air gap between the probe and the test surface.

 

A suitable ultrasonic couplant is therefore normally applied between the probe and tank wall.

 

Good coupling helps produce a more stable ultrasonic signal.

 

If readings fluctuate significantly, check:

 

Couplant

 

Probe contact

 

Surface condition

 

Instrument settings

 

Material sound velocity

 

Calibration or verification

 

before accepting the result.

 

Can You Measure a Painted Storage Tank?

 

This requires consideration.

 

Paint and other coatings can affect ultrasonic thickness measurements depending on the coating, instrument, measurement method and surface condition.

 

Do not automatically assume that every reading taken over paint represents only the underlying steel thickness.

 

For important inspection work, follow the manufacturer's instructions and applicable measurement procedure.

 

Surface preparation may be required at selected measurement points.

 

Storage Tank Corrosion: What Does UT345A Actually Tell You?

 

The UT345A measures material thickness.

 

It does not independently identify the corrosion mechanism or determine whether a tank is safe.

 

For example, if measurements are:

 

A1: 8.0 mm

A2: 7.9 mm

A3: 6.8 mm

A4: 7.9 mm

 

the instrument tells you that A3 has a lower measured thickness than the surrounding points.

 

The reason for that difference and whether it is acceptable require appropriate inspection and engineering evaluation.

 

What Is the Minimum Safe Tank Thickness?

 

There is no single minimum wall thickness that applies to every storage tank.

 

Acceptable thickness depends on factors including:

 

Tank design

 

Material

 

Original thickness

 

Tank dimensions

 

Contents

 

Loading

 

Corrosion allowance

 

Service conditions

 

Applicable standards

 

A handheld ultrasonic thickness gauge provides measurement data.

 

It should not be used by itself to declare a safety-critical tank suitable or unsuitable for continued service.

 

UT345A vs Coating Thickness Gauge for Tank Inspection

 

A painted steel tank may require two different types of thickness measurement.

 

UNI-T UT345A

 

Answers:

 

“How thick is the tank wall?”

 

This is material thickness measurement.

 

UNI-T UT343 Series

 

Answers:

 

“How thick is the protective coating?”

 

This is coating thickness measurement.

 

These measurements complement each other but should not be confused.

 

For corrosion-control programmes, coating condition and remaining base-metal thickness may both be relevant.

 

Tank Inspection for Preventive Maintenance

 

A useful preventive-maintenance approach is to create permanent or repeatable thickness measurement locations.

 

For example:

 

Tank: TK-01

Area: Lower Shell

Point: B3

Material: Carbon Steel

Instrument: UNI-T UT345A

Measured Thickness: 7.32 mm

Date: Inspection date

Remarks: Surface prepared and measurement repeated

 

At the next scheduled inspection, return to B3.

 

This creates a historical thickness record that can be compared over time.

 

Typical Applications in Malaysia

 

Ultrasonic tank-wall thickness measurement may be relevant to facilities such as:

 

Manufacturing factories

 

Water-treatment facilities

 

Palm oil mills

 

Chemical-processing facilities

 

Engineering plants

 

Utility facilities

 

Industrial maintenance contractors

 

Tank maintenance companies

 

The appropriate instrument and inspection procedure depend on the tank material and actual application.

 

Can UT345A Replace Professional Tank Inspection?

 

No single handheld instrument replaces a complete inspection programme.

 

Professional tank inspection may involve other methods and assessments depending on the equipment and applicable requirements.

 

The UT345A should be viewed as a portable thickness measurement tool that can support suitable maintenance and inspection work.

 

For critical tanks, pressure equipment or safety-related decisions, appropriately qualified personnel should interpret the measurements according to applicable engineering requirements and standards.

 

Is UNI-T UT345A Suitable for Your Tank?

 

Before purchasing, provide MTM Precision with information such as:

 

Tank material

 

Approximate wall thickness

 

Tank application

 

Surface condition

 

Whether the tank is painted or coated

 

Area you want to measure

 

Photo of the tank surface

 

This makes it easier to determine whether the UNI-T UT345A Ultrasonic Thickness Gauge is suitable for your application.

 

UNI-T UT345A Ultrasonic Thickness Gauge Malaysia

 

MTM Precision Sdn Bhd supplies UNI-T UT345A Ultrasonic Thickness Gauge for storage-tank thickness measurement, pipe-wall inspection, metal-thickness measurement and industrial maintenance applications in Malaysia.

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Contact MTM Precision for UNI-T UT345A Ultrasonic Thickness Gauge Malaysia, storage tank wall thickness measurement, corrosion monitoring and industrial maintenance applications.


 

22 Sep 2026