How to Set Upper and Lower Coating Thickness Limits on UNI-T UT343A Malaysia
How to Set Upper and Lower Coating Thickness Limits on UNI-T UT343A Malaysia
Content
If your coating specification requires a defined thickness range, checking every reading manually can slow down routine inspection.
The UNI-T UT343A Coating Thickness Gauge includes upper and lower limit settings, allowing users to identify measurements that fall outside their defined inspection range more quickly.
This can be useful for powder coating, painted metal, manufacturing and factory QA/QC applications in Malaysia.
However, there is one important rule:
The coating thickness gauge does not decide what your acceptable thickness should be.
The upper and lower limits must come from the relevant product, customer, coating or inspection specification.
What Are Upper and Lower Limits?
Suppose a factory has an approved coating requirement of:
80–120 μm
The inspection limits could therefore be defined as:
Lower Limit: 80 μm
Upper Limit: 120 μm
A measurement inside this range can then be assessed according to the factory's inspection procedure.
Measurements outside the defined range require attention.
For example:
95 μm → Within defined range
72 μm → Below lower limit
138 μm → Above upper limit
This makes repetitive inspection more efficient.
Where Should the Limit Values Come From?
Do not search online for a generic number and use it as your factory's pass/fail requirement.
The correct limits may come from:
Customer specification
Engineering drawing
Product specification
Coating manufacturer's technical information
Approved QA procedure
Project specification
Relevant inspection standard
Different products can require different coating thicknesses.
Therefore:
80–120 μm may be correct for one job and completely inappropriate for another.
Why Upper and Lower Limits Are Useful
Imagine a QA inspector checking 50 powder-coated components.
Without defined limits, the operator may need to repeatedly ask:
"Is 78 μm acceptable?"
"What about 125 μm?"
"Is 93 μm okay?"
With an approved inspection range already established, the measurement process becomes more systematic.
This is particularly useful for repetitive production inspection.
Example: Powder-Coated Electrical Cabinet
Assume the approved specification defines an acceptable DFT range.
The QA department sets the corresponding upper and lower inspection limits.
Measurements are then taken at predefined locations:
Door: 96 μm
Left Panel: 101 μm
Right Panel: 98 μm
Top: 103 μm
Rear: 99 μm
The readings can be compared directly with the approved range.
Now suppose the rear panel measures:
68 μm
Instead of immediately accepting the cabinet based on the other readings, the inspector can recheck the area and follow the company's non-conformance procedure if required.
What If One Point Fails?
One measurement outside the limit should trigger a defined response.
A practical troubleshooting sequence is:
1. Repeat the measurement
Confirm whether the result is repeatable.
2. Check the surface
Make sure the measurement location is clean.
3. Check probe position
Ensure stable contact.
4. Measure nearby points
Determine whether the issue is isolated or covers a larger area.
5. Verify the instrument if necessary
Make sure the unusual reading is not caused by a measurement problem.
6. Follow the QA procedure
If the coating is genuinely outside specification, follow the applicable inspection or corrective-action process.
Don't Adjust the Limit to Make a Product Pass
This is an important QA principle.
Suppose the approved lower limit is 80 μm and a component repeatedly measures 72 μm.
The solution is not:
Change the lower limit to 70 μm.
Inspection limits should reflect the approved requirement, not be changed simply to obtain a passing result.
Any specification change should follow the appropriate engineering, customer or quality approval process.
Upper Limit Is Important Too
Many users focus only on coatings that are too thin.
But an upper limit can also matter.
Excessive coating thickness may indicate:
Process variation
Excessive material application
Recoating
Production inconsistency
Depending on the coating system, excessive thickness may also fall outside the approved specification.
Therefore, QA/QC should monitor both:
Too Thin
and
Too Thick
where the specification requires it.
Use Multiple Measurement Points
A component should not necessarily pass simply because one location is within specification.
For example:
Point 1: 95 μm
Point 2: 98 μm
Point 3: 97 μm
Point 4: 62 μm
Point 5: 96 μm
The fourth measurement deserves investigation.
This is why a good coating inspection procedure defines:
Measurement locations + Number of readings + Acceptance limits + Action for failed readings
MIN, MAX and AVG Help With QA/QC
The UNI-T UT343A also provides:
MIN – Minimum reading
MAX – Maximum reading
AVG – Average reading
These functions can help inspectors review groups of measurements.
However, an acceptable average should not automatically override an individual out-of-specification reading if the applicable inspection procedure requires individual measurements to comply.
Always follow the actual acceptance criteria.
Example: Incoming Inspection
A Malaysian manufacturer receives powder-coated components from a supplier.
Instead of relying only on visual inspection, incoming QA can check selected components according to its sampling plan.
The process may look like:
Receive Parts
→ Select Inspection Samples
→ Confirm Coating Specification
→ Measure Defined Locations
→ Compare With Limits
→ Record Results
→ Accept / Investigate According to QA Procedure
This gives both purchasing and QA teams objective measurement data when discussing quality with suppliers.
Example: Production Line
Upper and lower limits can also support routine process monitoring.
If measurements begin trending toward one end of the acceptable range, production personnel may investigate the process before more significant deviations occur.
For example:
Batch 1 AVG: 92 μm
Batch 2 AVG: 96 μm
Batch 3 AVG: 104 μm
Batch 4 AVG: 115 μm
Even if the measurements remain within the approved limits, a consistent upward trend may be worth reviewing.
This is where coating thickness measurement becomes useful for process control, not only final rejection.
UNI-T UT343A for QA/QC Inspection
The UNI-T UT343A provides:
0–1750 μm measuring range
Fe/NFe substrate support
Automatic substrate recognition
Upper and lower limit settings
Single measurement
Continuous measurement
MAX/MIN/AVG
199 data storage
μm/mil units
These functions make it suitable for routine coating checks in:
Powder Coating | Metal Fabrication | Manufacturing | Automotive | Industrial Painting | QA/QC
Setting Up Coating Inspection in Malaysia
If your factory wants to use the UNI-T UT343A for pass/fail inspection, prepare these details first:
Coating: Paint / Powder Coating / Other
Substrate: Steel / Aluminium
Required Range: According to your approved specification
Measurement Locations: Where should operators measure?
Sampling: How many components and points?
Failure Action: What happens when a reading is outside the limit?
A good coating thickness gauge becomes much more useful when it is combined with a repeatable QA/QC procedure.
UNI-T UT343A Coating Thickness Gauge Malaysia
For UNI-T UT343A product enquiries and coating thickness measurement applications, contact:
MTM Precision Sdn Bhd
Showroom & Service Centre: Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Send us your coating type + substrate + expected thickness + application and we can help determine whether the UNI-T UT343A is suitable.
Serving customers across Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak.
23 Sep 2026