How to Set Upper and Lower Coating Thickness Limits on UNI-T UT343A Malaysia

How to Set Upper and Lower Coating Thickness Limits on UNI-T UT343A Malaysia

 

Content

 

If your coating specification requires a defined thickness range, checking every reading manually can slow down routine inspection.

 

The UNI-T UT343A Coating Thickness Gauge includes upper and lower limit settings, allowing users to identify measurements that fall outside their defined inspection range more quickly.

 

This can be useful for powder coating, painted metal, manufacturing and factory QA/QC applications in Malaysia.

 

However, there is one important rule:

 

The coating thickness gauge does not decide what your acceptable thickness should be.

 

The upper and lower limits must come from the relevant product, customer, coating or inspection specification.

 

What Are Upper and Lower Limits?

 

Suppose a factory has an approved coating requirement of:

 

80–120 μm

 

The inspection limits could therefore be defined as:

 

Lower Limit: 80 μm

 

Upper Limit: 120 μm

 

A measurement inside this range can then be assessed according to the factory's inspection procedure.

 

Measurements outside the defined range require attention.

 

For example:

 

95 μm → Within defined range

 

72 μm → Below lower limit

 

138 μm → Above upper limit

 

This makes repetitive inspection more efficient.

 

Where Should the Limit Values Come From?

 

Do not search online for a generic number and use it as your factory's pass/fail requirement.

 

The correct limits may come from:

 

Customer specification

 

Engineering drawing

 

Product specification

 

Coating manufacturer's technical information

 

Approved QA procedure

 

Project specification

 

Relevant inspection standard

 

Different products can require different coating thicknesses.

 

Therefore:

 

80–120 μm may be correct for one job and completely inappropriate for another.

 

Why Upper and Lower Limits Are Useful

 

Imagine a QA inspector checking 50 powder-coated components.

 

Without defined limits, the operator may need to repeatedly ask:

 

"Is 78 μm acceptable?"

 

"What about 125 μm?"

 

"Is 93 μm okay?"

 

With an approved inspection range already established, the measurement process becomes more systematic.

 

This is particularly useful for repetitive production inspection.

 

Example: Powder-Coated Electrical Cabinet

 

Assume the approved specification defines an acceptable DFT range.

 

The QA department sets the corresponding upper and lower inspection limits.

 

Measurements are then taken at predefined locations:

 

Door: 96 μm

Left Panel: 101 μm

Right Panel: 98 μm

Top: 103 μm

Rear: 99 μm

 

The readings can be compared directly with the approved range.

 

Now suppose the rear panel measures:

 

68 μm

 

Instead of immediately accepting the cabinet based on the other readings, the inspector can recheck the area and follow the company's non-conformance procedure if required.

 

What If One Point Fails?

 

One measurement outside the limit should trigger a defined response.

 

A practical troubleshooting sequence is:

 

1. Repeat the measurement

 

Confirm whether the result is repeatable.

 

2. Check the surface

 

Make sure the measurement location is clean.

 

3. Check probe position

 

Ensure stable contact.

 

4. Measure nearby points

 

Determine whether the issue is isolated or covers a larger area.

 

5. Verify the instrument if necessary

 

Make sure the unusual reading is not caused by a measurement problem.

 

6. Follow the QA procedure

 

If the coating is genuinely outside specification, follow the applicable inspection or corrective-action process.

 

Don't Adjust the Limit to Make a Product Pass

 

This is an important QA principle.

 

Suppose the approved lower limit is 80 μm and a component repeatedly measures 72 μm.

 

The solution is not:

 

Change the lower limit to 70 μm.

 

Inspection limits should reflect the approved requirement, not be changed simply to obtain a passing result.

 

Any specification change should follow the appropriate engineering, customer or quality approval process.

 

Upper Limit Is Important Too

 

Many users focus only on coatings that are too thin.

 

But an upper limit can also matter.

 

Excessive coating thickness may indicate:

 

Process variation

 

Excessive material application

 

Recoating

 

Production inconsistency

 

Depending on the coating system, excessive thickness may also fall outside the approved specification.

 

Therefore, QA/QC should monitor both:

 

Too Thin

 

and

 

Too Thick

 

where the specification requires it.

 

Use Multiple Measurement Points

 

A component should not necessarily pass simply because one location is within specification.

 

For example:

 

Point 1: 95 μm

Point 2: 98 μm

Point 3: 97 μm

Point 4: 62 μm

Point 5: 96 μm

 

The fourth measurement deserves investigation.

 

This is why a good coating inspection procedure defines:

 

Measurement locations + Number of readings + Acceptance limits + Action for failed readings

 

MIN, MAX and AVG Help With QA/QC

 

The UNI-T UT343A also provides:

 

MIN – Minimum reading

 

MAX – Maximum reading

 

AVG – Average reading

 

These functions can help inspectors review groups of measurements.

 

However, an acceptable average should not automatically override an individual out-of-specification reading if the applicable inspection procedure requires individual measurements to comply.

 

Always follow the actual acceptance criteria.

 

Example: Incoming Inspection

 

A Malaysian manufacturer receives powder-coated components from a supplier.

 

Instead of relying only on visual inspection, incoming QA can check selected components according to its sampling plan.

 

The process may look like:

 

Receive Parts

 

→ Select Inspection Samples

 

→ Confirm Coating Specification

 

→ Measure Defined Locations

 

→ Compare With Limits

 

→ Record Results

 

→ Accept / Investigate According to QA Procedure

 

This gives both purchasing and QA teams objective measurement data when discussing quality with suppliers.

 

Example: Production Line

 

Upper and lower limits can also support routine process monitoring.

 

If measurements begin trending toward one end of the acceptable range, production personnel may investigate the process before more significant deviations occur.

 

For example:

 

Batch 1 AVG: 92 μm

 

Batch 2 AVG: 96 μm

 

Batch 3 AVG: 104 μm

 

Batch 4 AVG: 115 μm

 

Even if the measurements remain within the approved limits, a consistent upward trend may be worth reviewing.

 

This is where coating thickness measurement becomes useful for process control, not only final rejection.

 

UNI-T UT343A for QA/QC Inspection

 

The UNI-T UT343A provides:

 

0–1750 μm measuring range

 

Fe/NFe substrate support

 

Automatic substrate recognition

 

Upper and lower limit settings

 

Single measurement

 

Continuous measurement

 

MAX/MIN/AVG

 

199 data storage

 

μm/mil units

 

These functions make it suitable for routine coating checks in:

 

Powder Coating | Metal Fabrication | Manufacturing | Automotive | Industrial Painting | QA/QC

 

Setting Up Coating Inspection in Malaysia

 

If your factory wants to use the UNI-T UT343A for pass/fail inspection, prepare these details first:

 

Coating: Paint / Powder Coating / Other

 

Substrate: Steel / Aluminium

 

Required Range: According to your approved specification

 

Measurement Locations: Where should operators measure?

 

Sampling: How many components and points?

 

Failure Action: What happens when a reading is outside the limit?

 

A good coating thickness gauge becomes much more useful when it is combined with a repeatable QA/QC procedure.

 

UNI-T UT343A Coating Thickness Gauge Malaysia

 

For UNI-T UT343A product enquiries and coating thickness measurement applications, contact:

 

MTM Precision Sdn Bhd

Showroom & Service Centre: Puchong, Selangor, Malaysia

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Send us your coating type + substrate + expected thickness + application and we can help determine whether the UNI-T UT343A is suitable.

 

Serving customers across Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak.


 

23 Sep 2026