Can a Used Total Station Be Used for Construction Setting Out Malaysia
A **used total station can be used for construction setting out** if its angle measurement, EDM, compensator, plummet and tribrach have been properly checked.
The instrument’s age is less important than its current condition and suitability for the project tolerance. A clean-looking total station should not be used for critical setting out until its performance has been verified.
## Construction Work a Used Total Station Can Support
Depending on its model and condition, a used total station may be suitable for:
- Building grid-line setting out
- Column and footing positions
- Boundary reference work
- Road and drainage alignment
- Earthwork points
- Pile-position checking
- As-built measurement
- Slope and elevation transfer
- General coordinate measurement
The project survey plan and required tolerance should determine whether the instrument is suitable.
## What Must Be Checked Before Setting Out?
### 1. Horizontal Angle Accuracy
The instrument should produce consistent horizontal-angle observations in both Face Left and Face Right positions.
Excessive collimation error can affect the position of setting-out points, particularly over longer distances.
### 2. Vertical Angle Accuracy
Check the vertical index and confirm that elevation-related observations are consistent.
A vertical-angle error may affect height transfer, slope work and trigonometric levelling.
### 3. EDM Performance
Test distance measurements using a suitable prism and known or independently verified distances.
Look for:
- Unstable readings
- Failure to measure
- Unexpected differences
- Slow measurement
- Prism-mode errors
- Reflectorless measurement problems
The correct prism constant and atmospheric settings must also be used.
### 4. Compensator Operation
The compensator should respond and settle normally after the instrument is levelled.
A faulty compensator can introduce errors even when the electronic level appears close to centre.
### 5. Optical or Laser Plummet
The plummet must remain aligned with the station point when the instrument is rotated.
A plummet error can shift the instrument position and affect every point set out from that station.
### 6. Tribrach Stability
Check the foot screws, locking mechanism and instrument mounting.
Movement between the total station and tribrach can make accurate setting out impossible.
## Confirm the Control Points
A checked total station cannot correct incorrect site control.
Before setting out, verify:
- Control-point coordinates
- Benchmark elevation
- Backsight-point identity
- Coordinate system
- Drawing revision
- Units of measurement
- Instrument and prism heights
Using the wrong control point or drawing version can create a major site error even when the instrument is working correctly.
## Perform an Independent Orientation Check
After setting up and orienting the total station, observe another known point.
Compare the measured result with the expected coordinate or direction. This independent check can help identify:
- Wrong backsight
- Incorrect station coordinates
- Prism-height error
- Orientation mistake
- Instrument movement
- Control-point problem
Do not rely on a single orientation without a check for critical work.
## Check Instrument and Prism Heights
Incorrect height entry is a common source of elevation errors.
Before measurement:
- Measure the instrument height carefully
- Confirm the prism-pole height
- Enter the correct values
- Check whether the prism is set to the intended height mark
- Record any changes during the work
A correct horizontal position can still have an incorrect elevation if the height values are wrong.
## Use the Correct Prism Constant
Different prisms may use different prism constants.
Confirm:
- Prism model
- Prism constant
- Instrument setting
- Pole configuration
- Whether reflectorless or prism mode is selected
Using an incorrect constant introduces a systematic distance error.
## Establish a Site-Check Routine
For construction setting out, a practical routine may include:
1. Inspect the tripod and tribrach.
2. Centre and level the total station.
3. Confirm station coordinates.
4. Observe the backsight.
5. Check a second known point.
6. Enter the correct prism constant.
7. Confirm instrument and prism heights.
8. Set out the required point.
9. Recheck the point independently.
10. Verify the orientation before leaving the station.
The checking method should match the project requirements and responsible survey procedure.
## When Is a Used Total Station Not Suitable?
Do not rely on the instrument for critical setting out when:
- Calibration condition is unknown
- EDM readings are inconsistent
- The compensator is unstable
- The plummet is misaligned
- The tribrach is loose
- The instrument has recently been dropped
- Data or coordinate functions are unreliable
- Required accuracy exceeds the model’s capability
- Repair history is unclear and testing cannot be completed
The instrument should be inspected before returning to site.
## Used Total Station for Backup Work
A checked used total station can also serve as a backup instrument.
This may reduce disruption when the primary unit is:
- Under calibration
- Sent for repair
- Required at another project
- Unavailable due to battery or accessory problems
The backup unit should still be checked periodically and stored correctly.
## Calibration Before Important Projects
Checking determines whether the total station is currently performing within the required tolerance.
Calibration compares the instrument with suitable references and records or adjusts its performance where appropriate.
Repair is required when a component such as the EDM, compensator, display, movement mechanism or optical system is faulty.
MTM Precision supports contractors and surveying teams using Topcon, Sokkia, Nikon, Leica, Trimble and Pentax total stations in Selangor, Kuala Lumpur, Johor and Penang.
Contact us for pre-purchase checking, calibration or repair assessment before using a used total station for important construction setting out.
**MTM Precision Sdn Bhd**
**Showroom & Service Centre:** No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
**Tel:** 03-8080 7172
**WhatsApp:** +6016-660 7346
**Email:** mtmpre@yahoo.com
**Website:** www.mtmpre.com.my
23 Sep 2026