Dianyang DP-25DR Thermal Camera for Solar PV Inspection Malaysia
What can technicians check?
• PV modules: Look for areas that appear warmer than comparable areas on nearby modules.
• Accessible DC connections: Check for unusual heating during operation.
• Combiner boxes and other electrical equipment: Compare similar components under similar loads.
Inspection conditions matter
Record the time, weather and operating conditions. Shade, reflections, viewing angle and changes in sunlight can affect the thermal image. Compare panels under similar conditions, and avoid treating a single image as proof of a defective module.
The DP-25DR has a 256 × 192 infrared detector, a 1080p visual camera and image fusion modes. Capture an overview image first, followed by a closer image that clearly identifies the area of concern.
What happens after finding a hot area?
Record the module or equipment location and arrange appropriate electrical testing by a qualified technician. Thermal imaging helps identify where to investigate; it does not establish whether the cause is a connection, cell, shading or another issue.
Before selecting the DP-25DR for solar PV work in Malaysia, consider how close technicians can safely get to the target and how small the area of concern may be. Its laser can measure distance up to 40 m, but that distance does not guarantee a useful temperature measurement of a small feature.
Send MTM Precision your solar inspection application and normal working distance to discuss whether the DP-25DR fits your team’s workflow.
MTM Precision Sdn Bhd
Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
23 Sep 2026