New Road Marking Over Old Marking: How to Measure Thickness Correctly Malaysia

Road maintenance projects often involve applying a new thermoplastic road marking over an existing marking.

This creates an important measurement question:

If a Digital Road Marking Thickness Gauge is used after remarking, does the reading represent the new layer only or the total height of the road marking?

Understanding this difference is important for contractors and QA/QC teams performing road marking thickness inspection.

WHAT DOES THE GAUGE ACTUALLY MEASURE?

A road marking thickness gauge measures the physical height difference between the top of the road marking and the surrounding pavement reference surface.

Therefore, when a new road marking is applied directly over an existing marking, the measured height may represent the combined profile of:

• Remaining old road marking
• Newly applied road marking
• Surface irregularities
• Pavement profile

The displayed result should not automatically be interpreted as the thickness of the new material alone.

EXAMPLE: NEW THERMOPLASTIC OVER EXISTING MARKING

Consider an existing thermoplastic line that has not been completely removed.

A contractor applies a new thermoplastic layer directly over it.

After the new marking has cooled, the thickness gauge measures the total height relative to the adjacent pavement.

This measurement can be useful for checking the finished profile.

However, it does not necessarily tell you exactly how much new thermoplastic material was added.

WHY DOES THIS MATTER FOR QA/QC?

Suppose a project specification requires verification of the newly applied marking thickness.

If an old marking remains underneath, measuring only the final surface height may produce a result that includes part of the previous marking.

This can create confusion during:

• Contractor internal QA/QC
• Consultant inspection
• Project handover
• Maintenance assessment
• Dispute investigation
• Compliance checking

The required measurement method should therefore be confirmed before work begins.

CHECK THE PROJECT SPECIFICATION FIRST

Before measuring new material over an existing road marking, determine what the project actually requires.

The specification may refer to:

• New material application thickness
• Finished road marking profile
• Minimum or maximum thickness
• Surface preparation
• Removal of existing markings
• Measurement locations
• Sampling frequency
• Inspection method

Do not assume that every road maintenance project uses the same acceptance method.

WHAT IF THE OLD ROAD MARKING HAS BEEN PARTIALLY REMOVED?

Partial removal creates another measurement challenge.

Some areas may contain:

• Remaining old thermoplastic
• Bare pavement
• Grinding marks
• Uneven surfaces
• Residual marking material

If new marking is subsequently applied across these areas, the finished thickness readings may vary.

Inspectors should record the underlying surface condition when interpreting the results.

CAN YOU MEASURE THE OLD MARKING BEFORE REMARKING?

Where appropriate and where the project procedure permits, documenting the existing marking before new application may provide useful reference information.

For example, measurements may be taken at representative locations before remarking and compared with measurements after the new marking is applied.

However, simply subtracting one reading from another should not automatically be treated as an exact measurement of the new layer.

The measurement locations, pavement reference and surface conditions may not be identical.

HOW TO MEASURE AFTER REMARKING

A practical field approach is:

Step 1 – Confirm the Inspection Requirement

Determine whether the project requires finished profile measurement or measurement specifically related to the new application.

Step 2 – Allow the New Marking to Cool or Cure

Do not measure before the material is suitable for dry thickness measurement.

Step 3 – Inspect the Surrounding Pavement

Look for remaining old markings, grinding, surface damage or uneven pavement.

Step 4 – Position the Gauge Correctly

Make sure the instrument references the adjacent pavement properly.

Step 5 – Take Multiple Measurements

Measure several representative locations instead of relying on one reading.

Step 6 – Record Surface Conditions

Note whether the measurement is over an existing marking, partially removed marking or prepared pavement.

Step 7 – Compare Against the Correct Requirement

Evaluate the results according to the applicable project specification or inspection procedure.

WHY CAN READINGS VARY AFTER REMARKING?

Variation may result from:

• Different remaining thickness of the old marking
• Uneven grinding or removal
• Pavement texture
• New thermoplastic application thickness
• Material flow
• Application speed
• Gauge positioning

Large variations should be investigated rather than automatically attributed to instrument error.

SHOULD OLD ROAD MARKINGS BE REMOVED FIRST?

Whether an existing marking needs to be removed depends on the road maintenance method and project specification.

This is a construction and project requirement rather than something determined by the thickness gauge itself.

Contractors should follow the applicable specification regarding surface preparation and removal of existing markings.

ROAD MARKING THICKNESS INSPECTION FOR MAINTENANCE PROJECTS

A Digital Road Marking Thickness Gauge can support inspection work involving:

• Road remarking
• Highway maintenance
• Thermoplastic replacement
• Existing marking assessment
• Parking area maintenance
• Junction remarking
• Pedestrian crossing maintenance
• Contractor QA/QC

The important point is to understand exactly what physical dimension is being measured.

ROAD MARKING THICKNESS GAUGE SUPPLIER MALAYSIA

MTM Precision supplies Digital Road Marking Thickness Gauges and other road inspection instruments for road contractors, civil engineering companies, consultants, laboratories and QA/QC teams in Malaysia.

For maintenance or remarking projects, you can send us your tender specification, BOQ or measurement requirement before purchasing.

Our team can assist in checking the instrument against the intended measurement application.

MTM Precision Sdn Bhd
Puchong Showroom & Service Centre

Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my

Serving Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak, Malaysia.