Why Lux Readings Change from Morning to Afternoon with UNI-T UT383S Malaysia
Daylight direction, cloud movement, curtains, window reflections and artificial-light operation can all change the illumination reaching the sensor. The **UNI-T UT383S Digital Light Meter** records the actual visible-light level at the measurement point under the conditions present at that moment.
## Reason 1: The Sun Changes Position
The angle of sunlight changes throughout the day.
A room may receive:
- Direct morning sun
- Indirect midday light
- Strong afternoon sun
- Little daylight near sunset
The result depends on the window direction, surrounding buildings and location of the measurement point.
A desk near an east-facing window may be much brighter in the morning, while another area receives stronger light later in the day.
## Reason 2: Cloud Cover Changes Quickly
Cloud movement can cause the UT383S reading to rise and fall even when the sensor remains still.
In Malaysia, conditions may change between:
- Clear sky
- Light cloud
- Heavy cloud
- Rain
- Bright periods after rain
Record the weather condition when daylight affects the measurement.
## Reason 3: Curtains and Blinds Change the Reading
The position and angle of blinds can significantly change indoor illumination.
Before comparing readings, confirm whether the curtains or blinds are:
- Fully open
- Fully closed
- Partly open
- Tilted upward
- Tilted downward
- Different from the previous test
Photographs can help reproduce the same condition later.
## Reason 4: Artificial Lights May Be Different
Check whether the same fixtures were operating during both tests.
Differences may occur when:
- One lighting circuit is switched off
- Automatic controls respond to daylight
- Occupancy sensors turn lights on or off
- A lamp has failed
- Dimming settings have changed
- A task light is operating
- Maintenance work has been performed
Record which lights were switched on.
## Reason 5: Doors and Windows Affect Light Distribution
An open door can allow light from a corridor or outdoor area to enter the room.
Similarly, open or closed windows, partitions and glass doors may change reflections and illumination.
Record the condition of:
- Doors
- Windows
- Glass partitions
- Movable walls
- Internal blinds
- External shading
These details are important for repeat measurements.
## Reason 6: Furniture and People Create Shadows
Lux readings may change when:
- A person stands near the sensor
- A chair is moved
- A computer monitor blocks light
- Boxes are placed on the desk
- Shelves are installed
- Machinery changes position
- A partition is added
- Indoor plants are moved
Measure under the normal operating arrangement and document major changes.
## Reason 7: The Sensor Position Is Not Identical
Even within the same room, moving the sensor a short distance may produce a different result.
For repeatable UT383S measurements:
- Mark the measurement point
- Use the same sensor height
- Keep the same orientation
- Place it on the same surface
- Move away to avoid shadows
- Use the same Lux or Fc unit
Do not compare a desk-level reading with one taken while holding the sensor above the desk.
## Reason 8: Reflections Change
Light-coloured walls, polished surfaces, glass and metal can reflect light toward the sensor.
Changes to:
- Wall colour
- Furniture
- Floor finish
- Display material
- Machinery
- Whiteboards
- Reflective packaging
may affect the reading even when the lighting fixtures remain unchanged.
## How to Perform a Repeatable Time-of-Day Survey
Use a planned procedure:
1. Mark the measurement points.
2. Use the same UT383S meter.
3. Select the same unit.
4. Keep the sensor height consistent.
5. Record morning, afternoon and evening readings.
6. Note the exact time.
7. Record the weather.
8. Record curtains and blinds.
9. Identify which lights are operating.
10. Note any furniture or activity changes.
Repeat the survey over several days if daylight behaviour is important.
## Suggested Record
| Point | Time | Lux Reading | Weather | Blinds | Artificial Lights | Observation |
|---|---|---:|---|---|---|---|
| A1 | Morning | Record value | Record condition | Record position | On/Off | Window side |
| A1 | Afternoon | Record value | Record condition | Record position | On/Off | Same sensor point |
| A1 | Evening | Record value | Record condition | Record position | On/Off | No daylight |
| A2 | Morning | Record value | Record condition | Record position | On/Off | Internal wall |
| A2 | Afternoon | Record value | Record condition | Record position | On/Off | Same sensor point |
This separates actual lighting change from measurement inconsistency.
## Daylight Condition vs Artificial-Lighting Condition
Two different surveys may be useful.
### Normal Operating Survey
Measure with daylight, artificial lighting and normal room use. This represents the conditions experienced by occupants at that time.
### Controlled Artificial-Lighting Survey
Reduce daylight influence where practical and measure with a defined set of artificial lights operating. This supports more repeatable comparison of the lighting installation.
The report should state which method was used.
## When Should the Meter Be Checked?
Further checking may be appropriate when readings remain inconsistent under a stable indoor light source and controlled conditions.
Before suspecting a fault:
- Keep the sensor still
- Remove changing daylight
- Avoid moving shadows
- Check Data Hold status
- Inspect the sensor surface
- Replace weak batteries
- Check the sensor cable
- Repeat the measurement
If abnormal behaviour continues, inspection or calibration may be required depending on the application.
## Important Limitation
The UT383S measures illumination at the time of the test. It does not automatically calculate:
- Daily daylight exposure
- Long-term average illumination
- Lighting compliance
- Glare
- Flicker
- Colour quality
- Energy consumption
Long-term studies may require data logging, defined measurement intervals and a controlled assessment method.
## Final Recommendation
Different Lux readings at different times are often a real reflection of changing environmental conditions.
To make the results comparable, control and record:
- Measurement point
- Sensor height
- Sensor direction
- Time
- Weather
- Daylight condition
- Artificial lights
- Blinds and curtains
- Room arrangement
For UNI-T UT383S enquiries and assistance selecting a digital Lux meter for office, factory, classroom or building applications in Malaysia, contact MTM Precision.
**MTM Precision Sdn Bhd**
**Showroom & Service Centre:** No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
**Tel:** 03-8080 7172
**WhatsApp:** +6016-660 7346
**Email:** mtmpre@yahoo.com
**Website:** www.mtmpre.com.my
25 Sep 2026