TASI TA642C for Data Centre Airflow and Cooling Inspection Malaysia
TASI TA642C for Data Centre Airflow and Cooling Inspection Malaysia
Data centres depend heavily on controlled airflow to remove heat from IT equipment and deliver cooling where it is required.
When technicians discover hot spots, uneven rack inlet temperatures or differences in cooling performance, temperature measurement alone may not provide the complete picture.
Measuring air velocity and airflow at suitable locations can provide additional information.
The TASI TA642C High Accuracy Digital Anemometer can support portable airflow measurements during data centre cooling inspection, HVAC maintenance and troubleshooting in Malaysia.
Why Does Airflow Matter in a Data Centre?
Servers and other IT equipment generate heat continuously.
Cooling systems must move conditioned air toward equipment and remove heated air efficiently.
Airflow problems may contribute to conditions such as:
Uneven cooling
Localised hot spots
Weak airflow in selected areas
Poor air distribution
Mixing between hot and cold air
Cooling inefficiency
Differences between racks or aisles
Airflow measurement helps technicians investigate how air is moving rather than looking only at temperature.
Where Can Airflow Be Checked?
Depending on the cooling design and measurement objective, technicians may take suitable measurements around:
Cooling air outlets
Floor grilles
Perforated floor tiles
Supply air locations
Return air locations
Cold aisle areas
Hot aisle areas
Selected ventilation points
Measurements should be taken without unnecessarily interfering with normal airflow.
Step 1: Identify the Cooling Problem
Before measuring, determine what you are trying to investigate.
For example:
Problem: One rack has higher inlet temperature.
Instead of measuring randomly throughout the entire data centre, technicians can compare airflow conditions around the affected rack with nearby racks operating under similar conditions.
This makes the investigation more focused.
Step 2: Measure Air Velocity
Position the TASI TA642C probe at the selected measurement point.
Allow the reading to stabilise before recording it.
If the measurement area is large, take readings at several points because airflow may not be uniform.
The TA642C's separate probe configuration can be useful when technicians need to position the sensor while keeping the main instrument convenient to view.
Step 3: Compare Similar Locations
Comparison is often more useful than an isolated measurement.
For example:
Rack A: Normal temperature and expected relative airflow
Rack B: Normal temperature and similar airflow
Rack C: Higher temperature and noticeably lower airflow
Rack C now becomes a logical location for further investigation.
The airflow measurement does not automatically identify the cause, but it provides another piece of diagnostic information.
Air Velocity vs Airflow
Air velocity tells technicians how fast air is moving.
Airflow tells them how much air volume is moving through a defined area.
The TA642C supports airflow functions including:
CFM – Cubic Feet per Minute
CMM – Cubic Metres per Minute
CMS – Cubic Metres per Second
For airflow calculations, the correct measurement area is important.
This can be useful when technicians need more information than a simple air velocity reading.
Checking Perforated Floor Tiles
Raised-floor data centres may distribute cooling air through perforated tiles or grilles.
A technician may compare selected floor outlets to identify significant differences in airflow.
For example, several similar outlets may show relatively consistent readings while one area produces much lower airflow.
Further investigation may then consider:
Air distribution
Obstructions
Floor configuration
Cooling system operation
Damper settings
Other relevant airflow conditions
Measurements should always be interpreted according to the actual cooling design.
Hot Aisle and Cold Aisle Investigation
Airflow measurement can complement temperature measurements when investigating hot aisle and cold aisle performance.
If a particular rack inlet is warmer than surrounding racks, technicians can check whether cooling airflow around that location differs.
This is more informative than assuming every high-temperature reading is caused by insufficient cooling capacity.
The issue may instead involve how the available cooling air is distributed.
Airflow and Temperature Should Be Used Together
A useful data centre investigation may combine:
Temperature measurement – Is a location unusually warm?
Airflow measurement – Is air movement different from comparable locations?
Together, these measurements can provide better troubleshooting information.
Depending on the facility, technicians may also monitor:
Relative humidity
Differential pressure
Electrical load
Power consumption
Indoor air conditions
Equipment operating status
No single measurement tells the complete story.
Example: One Rack Is Running Hot
Imagine several racks operating in the same cold aisle.
Most rack inlet temperatures are relatively consistent, but one rack is noticeably warmer.
The technician measures airflow at comparable locations.
If the affected rack also has substantially different airflow, further investigation can focus on the local air distribution.
Possible factors could include:
Obstruction
Grille or tile condition
Air bypass
Cooling distribution
Equipment arrangement
Containment condition
The TA642C does not diagnose these issues automatically.
It provides measurement data to support the investigation.
Before and After Airflow Adjustment
Airflow measurements can also document changes made during maintenance.
Before Adjustment
Record temperature and airflow at selected locations.
Make the Required Change
Adjust the relevant cooling or airflow configuration according to the facility's procedures.
After Adjustment
Repeat the measurements at the same locations under comparable operating conditions.
This provides quantitative before-and-after information.
Preventive Maintenance Trending
Data centre facility teams can also establish selected airflow measurement points.
Periodic readings may help identify changes over time.
For example:
Baseline: 100%
Later inspection: Similar relative performance
Next inspection: Significant reduction at one location
A change does not automatically identify a fault, but it provides a reason for further investigation.
Does TA642C Replace Data Centre Environmental Monitoring?
No.
The TA642C is a portable measurement instrument.
It does not replace permanent data centre monitoring systems, rack temperature sensors, Building Management Systems (BMS) or Data Centre Infrastructure Management (DCIM) platforms.
Its value is in portable spot checking, comparison, maintenance and troubleshooting.
This makes it useful when technicians need to investigate a specific location rather than install another permanent monitoring point.
Useful for Data Centre Facility Teams
Potential users include:
Data centre facility management
HVAC contractors
M&E contractors
Cooling system technicians
Building maintenance teams
Commissioning and maintenance personnel
The instrument can support routine inspection as well as troubleshooting when unusual airflow or temperature conditions are observed.
TASI TA642C Data Centre Airflow Meter Malaysia
The TASI TA642C High Accuracy Digital Anemometer can support portable air velocity and airflow measurements for data centre cooling inspection and HVAC maintenance.
By combining airflow measurements with temperature and other environmental data, technicians can develop a clearer picture of cooling conditions around racks, aisles and selected air distribution points.
For product availability and technical enquiries:
MTM Precision Sdn Bhd
Showroom & Service Centre: Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision for more information about the TASI TA642C Digital Anemometer for data centre airflow, cooling inspection and HVAC maintenance in Malaysia.
26 Sep 2026