TASI TA813B+ for Factory Electrical Preventive Maintenance Malaysia
TASI TA813B+ for Factory Electrical Preventive Maintenance Malaysia
Factory electrical maintenance should not begin only after a machine stops.
By recording electrical measurements while equipment is operating normally, maintenance teams can establish reference data and identify changes during future inspections.
The TASI TA813B+ True RMS Digital Clamp Meter combines AC/DC current, True RMS, Inrush Current, VFD voltage, High/Low-Z voltage, frequency, temperature and other electrical measurement functions, making it suitable for a wide range of factory preventive maintenance tasks.
What Is Electrical Preventive Maintenance?
Preventive maintenance involves inspecting and checking equipment before an unexpected failure causes production downtime.
For electrical systems, technicians may routinely check:
Motors
Pumps
Fans and blowers
Air compressors
HVAC equipment
VFD systems
Electrical panels
Control systems
DC power supplies
Production machinery
The objective is not simply to collect numbers.
The real value comes from comparing current measurements with normal baseline data, equipment specifications and previous inspections.
Start with a Baseline
Suppose a motor is operating normally today.
This is a good time to record its electrical condition.
For example:
Motor A
Running Current β Record
Supply Voltage β Record
Frequency β Record
Temperature β Record where applicable
Operating Condition β Record
When the same motor develops a problem several months later, technicians have historical information for comparison.
Without a baseline, it can be difficult to know whether a new reading represents a meaningful change.
Check Motor Running Current
Motor current is one of the most useful routine electrical measurements.
A technician can use the TA813B+ to check current on the appropriate individual conductor.
The measured result can be compared with:
Previous readings
Motor information
Equipment specifications
Similar motors
Operating load
If current has changed significantly, further investigation may be justified.
However:
Abnormal Current β Automatic Motor Failure
The cause could also involve mechanical loading, supply conditions, VFD settings or the driven equipment.
Check Motor Starting Current
A motor may operate normally after starting but still experience a startup-related problem.
The Inrush Current function on the TA813B+ allows technicians to investigate the high-current event occurring during startup.
This is useful when investigating complaints such as:
Breaker trips during startup
Compressor difficult to start
Motor takes longer to accelerate
Generator voltage drops when equipment starts
Pump startup causes electrical problems
A useful maintenance record can contain both:
Inrush Current + Running Current
These measurements describe different operating conditions.
Check VFD-Driven Equipment
Variable Frequency Drives are common in modern factories.
They are frequently used with:
Pumps
Fans
Blowers
Conveyors
Compressors
Process equipment
Production machinery
A basic troubleshooting path can be:
Power Supply β VFD β Motor β Mechanical Load
The TA813B+ includes a VFD voltage measurement function, providing another useful capability for technicians working with drive-controlled motors.
Always interpret electrical measurements together with VFD fault codes and the drive manufacturer's technical information.
Pump Preventive Maintenance
A pump problem is not necessarily a pump problem alone.
The system may include:
Electrical Supply β VFD / Starter β Motor β Coupling β Pump β Process
Electrical measurements can help maintenance teams evaluate the motor and supply side.
For example:
Running current
Startup current
Voltage
Frequency
But pump condition may also require mechanical and process measurements.
This is where electrical and condition-monitoring instruments can complement each other.
Combine Clamp Meter and Vibration Meter
For rotating machinery, combining electrical and mechanical measurements can provide a more complete picture.
TASI TA813B+
β Current
β Voltage
β Frequency
β Electrical behaviour
Vibration Meter
β Vibration level
β Mechanical behaviour
Consider a pump motor where both current and vibration have increased compared with previous measurements.
That combination provides stronger evidence that the equipment deserves further investigation than either reading considered alone.
This approach is useful for:
Motor + Pump + Fan + Blower + Compressor
Air Compressor Maintenance
Air compressors can be critical factory equipment.
Electrical checks may include:
Starting current
Running current
Supply voltage
Electrical connections
Motor behaviour
If a compressor begins drawing different current compared with its historical baseline, maintenance teams can investigate further before assuming the motor itself is defective.
Possible areas may include:
Motor β Compressor β Mechanical Load β Air System β Control System
Cooling Tower and HVAC Equipment
Factories also depend heavily on building and process cooling systems.
Typical equipment includes:
Cooling tower fans
Chilled-water pumps
AHU fans
Ventilation motors
Compressors
VFDs
The TA813B+ can therefore serve both production-equipment maintenance and general facility electrical maintenance.
Electrical Panel Troubleshooting
Factories contain many electrical and control panels.
Technicians may encounter situations where an unexpected voltage reading appears on a conductor.
The TA813B+ provides High/Low Impedance voltage measurement.
Low-Z can be useful when investigating suspected ghost or induced voltage.
However, unexpected voltage must always be treated seriously until the actual electrical condition has been verified.
Never assume a reading is harmless simply because ghost voltage is suspected.
AC and DC Systems in Modern Factories
Factories are no longer purely AC environments.
A modern production machine may contain:
AC Incoming Supply
β
VFD / Servo System
β
Motor
while the same machine also contains:
AC Supply
β
DC Power Supply
β
PLC + Sensors + Relays + Control System
Because the TA813B+ supports both AC and DC current measurement, technicians can use it across a wider range of these systems.
Suggested Factory Inspection Record
Maintenance teams can create a simple inspection table.
EquipmentRunning CurrentInrushVoltageFrequencyVibrationStatusPump 01RecordRecordRecordRecordRecordNormalMotor 02RecordRecordRecordRecordRecordMonitorFan 03RecordβRecordRecordRecordNormalCompressor 01RecordRecordRecordRecordRecordCheck
The important point is consistency.
Measurements taken at similar operating conditions are generally more useful for trending than random measurements taken under completely different loads.
From Breakdown Maintenance to Preventive Maintenance
A reactive maintenance approach looks like:
Machine Stops β Technician Checks β Repair β Restart
A preventive approach adds routine information before failure:
Normal Operation β Measure β Record β Compare β Investigate Change β Maintenance Action
The second approach gives the maintenance team more historical information when troubleshooting begins.
What TA813B+ Can and Cannot Tell You
A clamp meter provides valuable electrical measurements.
But it cannot diagnose every factory problem by itself.
For example, a motor drawing high current could involve:
Electrical supply
Motor condition
Mechanical overload
Pump problem
Bearing problem
Alignment
Process condition
Incorrect VFD parameters
Therefore, the best maintenance strategy often combines several tools.
Depending on the equipment, this could include:
Clamp Meter + Vibration Meter + Thermal Camera + Tachometer + Insulation Tester
Each instrument answers a different maintenance question.
Why TA813B+ Fits a Factory Maintenance Toolkit
The TA813B+ combines several useful functions in one handheld instrument:
True RMS
AC/DC Current
Inrush Current
VFD Voltage
High/Low-Z
Frequency
Temperature
NCV
Resistance / Capacitance / Continuity
This makes it relevant for technicians who move between different machines and electrical systems during the same maintenance shift.
Typical Users
The TA813B+ can be considered for:
Factory maintenance departments
Electrical technicians
Facility maintenance teams
HVAC technicians
Machinery service technicians
Electrical contractors
Automation technicians
Engineering departments
It is particularly useful where maintenance work involves a mixture of motors, VFDs, AC systems and DC control circuits.
Important Electrical Safety
Preventive maintenance frequently involves measurements around energized electrical equipment.
Only appropriately trained personnel should perform these measurements.
Before testing, verify:
Measurement category
Maximum voltage and current ratings
Meter condition
Test lead condition
Circuit configuration
PPE requirements
Site electrical safety procedures
Always follow the equipment manufacturer's instructions and applicable electrical safety requirements.
TASI TA813B+ Factory Maintenance Clamp Meter Malaysia
Looking for the TASI TA813B+ True RMS Digital Clamp Meter for factory electrical preventive maintenance, motors, pumps, compressors or VFD applications?
Contact:
MTM Precision Sdn Bhd
Showroom & Service Centre
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supporting industrial customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
26 Sep 2026