TASI TA813B+ for Factory Electrical Preventive Maintenance Malaysia

TASI TA813B+ for Factory Electrical Preventive Maintenance Malaysia


Factory electrical maintenance should not begin only after a machine stops.


By recording electrical measurements while equipment is operating normally, maintenance teams can establish reference data and identify changes during future inspections.


The TASI TA813B+ True RMS Digital Clamp Meter combines AC/DC current, True RMS, Inrush Current, VFD voltage, High/Low-Z voltage, frequency, temperature and other electrical measurement functions, making it suitable for a wide range of factory preventive maintenance tasks.


What Is Electrical Preventive Maintenance?


Preventive maintenance involves inspecting and checking equipment before an unexpected failure causes production downtime.


For electrical systems, technicians may routinely check:


Motors


Pumps


Fans and blowers


Air compressors


HVAC equipment


VFD systems


Electrical panels


Control systems


DC power supplies


Production machinery


The objective is not simply to collect numbers.


The real value comes from comparing current measurements with normal baseline data, equipment specifications and previous inspections.


Start with a Baseline


Suppose a motor is operating normally today.


This is a good time to record its electrical condition.


For example:


Motor A


Running Current β†’ Record


Supply Voltage β†’ Record


Frequency β†’ Record


Temperature β†’ Record where applicable


Operating Condition β†’ Record


When the same motor develops a problem several months later, technicians have historical information for comparison.


Without a baseline, it can be difficult to know whether a new reading represents a meaningful change.


Check Motor Running Current


Motor current is one of the most useful routine electrical measurements.


A technician can use the TA813B+ to check current on the appropriate individual conductor.


The measured result can be compared with:


Previous readings


Motor information


Equipment specifications


Similar motors


Operating load


If current has changed significantly, further investigation may be justified.


However:


Abnormal Current β‰  Automatic Motor Failure


The cause could also involve mechanical loading, supply conditions, VFD settings or the driven equipment.


Check Motor Starting Current


A motor may operate normally after starting but still experience a startup-related problem.


The Inrush Current function on the TA813B+ allows technicians to investigate the high-current event occurring during startup.


This is useful when investigating complaints such as:


Breaker trips during startup


Compressor difficult to start


Motor takes longer to accelerate


Generator voltage drops when equipment starts


Pump startup causes electrical problems


A useful maintenance record can contain both:


Inrush Current + Running Current


These measurements describe different operating conditions.


Check VFD-Driven Equipment


Variable Frequency Drives are common in modern factories.


They are frequently used with:


Pumps


Fans


Blowers


Conveyors


Compressors


Process equipment


Production machinery


A basic troubleshooting path can be:


Power Supply β†’ VFD β†’ Motor β†’ Mechanical Load


The TA813B+ includes a VFD voltage measurement function, providing another useful capability for technicians working with drive-controlled motors.


Always interpret electrical measurements together with VFD fault codes and the drive manufacturer's technical information.


Pump Preventive Maintenance


A pump problem is not necessarily a pump problem alone.


The system may include:


Electrical Supply β†’ VFD / Starter β†’ Motor β†’ Coupling β†’ Pump β†’ Process


Electrical measurements can help maintenance teams evaluate the motor and supply side.


For example:


Running current


Startup current


Voltage


Frequency


But pump condition may also require mechanical and process measurements.


This is where electrical and condition-monitoring instruments can complement each other.


Combine Clamp Meter and Vibration Meter


For rotating machinery, combining electrical and mechanical measurements can provide a more complete picture.


TASI TA813B+


β†’ Current

β†’ Voltage

β†’ Frequency

β†’ Electrical behaviour


Vibration Meter


β†’ Vibration level

β†’ Mechanical behaviour


Consider a pump motor where both current and vibration have increased compared with previous measurements.


That combination provides stronger evidence that the equipment deserves further investigation than either reading considered alone.


This approach is useful for:


Motor + Pump + Fan + Blower + Compressor


Air Compressor Maintenance


Air compressors can be critical factory equipment.


Electrical checks may include:


Starting current


Running current


Supply voltage


Electrical connections


Motor behaviour


If a compressor begins drawing different current compared with its historical baseline, maintenance teams can investigate further before assuming the motor itself is defective.


Possible areas may include:


Motor β†’ Compressor β†’ Mechanical Load β†’ Air System β†’ Control System


Cooling Tower and HVAC Equipment


Factories also depend heavily on building and process cooling systems.


Typical equipment includes:


Cooling tower fans


Chilled-water pumps


AHU fans


Ventilation motors


Compressors


VFDs


The TA813B+ can therefore serve both production-equipment maintenance and general facility electrical maintenance.


Electrical Panel Troubleshooting


Factories contain many electrical and control panels.


Technicians may encounter situations where an unexpected voltage reading appears on a conductor.


The TA813B+ provides High/Low Impedance voltage measurement.


Low-Z can be useful when investigating suspected ghost or induced voltage.


However, unexpected voltage must always be treated seriously until the actual electrical condition has been verified.


Never assume a reading is harmless simply because ghost voltage is suspected.


AC and DC Systems in Modern Factories


Factories are no longer purely AC environments.


A modern production machine may contain:


AC Incoming Supply


↓


VFD / Servo System


↓


Motor


while the same machine also contains:


AC Supply


↓


DC Power Supply


↓


PLC + Sensors + Relays + Control System


Because the TA813B+ supports both AC and DC current measurement, technicians can use it across a wider range of these systems.


Suggested Factory Inspection Record


Maintenance teams can create a simple inspection table.


EquipmentRunning CurrentInrushVoltageFrequencyVibrationStatusPump 01RecordRecordRecordRecordRecordNormalMotor 02RecordRecordRecordRecordRecordMonitorFan 03Recordβ€”RecordRecordRecordNormalCompressor 01RecordRecordRecordRecordRecordCheck


The important point is consistency.


Measurements taken at similar operating conditions are generally more useful for trending than random measurements taken under completely different loads.


From Breakdown Maintenance to Preventive Maintenance


A reactive maintenance approach looks like:


Machine Stops β†’ Technician Checks β†’ Repair β†’ Restart


A preventive approach adds routine information before failure:


Normal Operation β†’ Measure β†’ Record β†’ Compare β†’ Investigate Change β†’ Maintenance Action


The second approach gives the maintenance team more historical information when troubleshooting begins.


What TA813B+ Can and Cannot Tell You


A clamp meter provides valuable electrical measurements.


But it cannot diagnose every factory problem by itself.


For example, a motor drawing high current could involve:


Electrical supply


Motor condition


Mechanical overload


Pump problem


Bearing problem


Alignment


Process condition


Incorrect VFD parameters


Therefore, the best maintenance strategy often combines several tools.


Depending on the equipment, this could include:


Clamp Meter + Vibration Meter + Thermal Camera + Tachometer + Insulation Tester


Each instrument answers a different maintenance question.


Why TA813B+ Fits a Factory Maintenance Toolkit


The TA813B+ combines several useful functions in one handheld instrument:


True RMS


AC/DC Current


Inrush Current


VFD Voltage


High/Low-Z


Frequency


Temperature


NCV


Resistance / Capacitance / Continuity


This makes it relevant for technicians who move between different machines and electrical systems during the same maintenance shift.


Typical Users


The TA813B+ can be considered for:


Factory maintenance departments


Electrical technicians


Facility maintenance teams


HVAC technicians


Machinery service technicians


Electrical contractors


Automation technicians


Engineering departments


It is particularly useful where maintenance work involves a mixture of motors, VFDs, AC systems and DC control circuits.


Important Electrical Safety


Preventive maintenance frequently involves measurements around energized electrical equipment.


Only appropriately trained personnel should perform these measurements.


Before testing, verify:


Measurement category


Maximum voltage and current ratings


Meter condition


Test lead condition


Circuit configuration


PPE requirements


Site electrical safety procedures


Always follow the equipment manufacturer's instructions and applicable electrical safety requirements.


TASI TA813B+ Factory Maintenance Clamp Meter Malaysia


Looking for the TASI TA813B+ True RMS Digital Clamp Meter for factory electrical preventive maintenance, motors, pumps, compressors or VFD applications?


Contact:


MTM Precision Sdn Bhd


Showroom & Service Centre

No 29-1 & 2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my


Supporting industrial customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.



26 Sep 2026