How to Find High Splice Loss with NOYAFA NF-9816 OTDR Malaysia
How to Find High Splice Loss with NOYAFA NF-9816 OTDR Malaysia
A fiber optic link can still carry a signal even when one of its splices has excessive loss.
This can make troubleshooting difficult.
The network may remain operational, but technicians may notice lower-than-expected optical power, reduced link margin or unstable communication.
An OTDR such as the NOYAFA NF-9816 can help technicians identify loss events along a fiber and estimate where a suspicious splice is located.
This is useful for FTTH contractors, fiber installers, telecommunications technicians, CCTV contractors and maintenance teams in Malaysia.
What Is Fiber Splice Loss?
Fiber splicing joins two optical fibers together.
When performed correctly, a fusion splice should introduce relatively low loss.
However, splice performance can be affected by factors such as:
Poor fiber preparation
Incorrect cleaving
Contamination
Fiber misalignment
Poor fusion quality
Mechanical stress
Fiber movement
Incompatible fiber characteristics
A problematic splice may introduce more attenuation than expected.
What Does a Bad Splice Look Like on an OTDR?
An OTDR sends optical pulses through the fiber and analyzes the returned signal.
A splice may appear as a non-reflective loss event on the OTDR trace.
If the loss at a particular event is higher than expected, technicians can investigate whether it corresponds to a known splice location.
For example:
0 m — Test Point
450 m — Splice 1
980 m — Splice 2
1,520 m — Splice 3
2,100 m — Fiber End
If the event around 980 metres shows unusual loss compared with the other splice events, the technician can investigate Splice 2.
This is much more efficient than reopening every splice enclosure along the route.
Use the NOYAFA NF-9816 Event Map
The NF-9816 includes an Event Map function.
This provides a simplified representation of detected events along the fiber.
For technicians who do not read OTDR traces every day, Event Map can make the initial investigation easier.
The technician can first identify:
Event distance
Event type
Relative loss
Fiber endpoint
Then the corresponding physical location can be checked against the network documentation.
Match OTDR Distance with the Fiber Route
Suppose the NF-9816 identifies a suspicious event approximately 1.35 km from the test point.
Do not assume that this means the problem is exactly 1.35 km away in a straight line.
The installed cable may contain:
Service loops
Spare cable coils
Vertical building runs
Underground ducts
Cable tray routing
Additional cable inside cabinets
Instead, compare the OTDR distance with:
As-built drawings + splice records + cable markers + physical route
This provides a more accurate way to identify the suspected splice.
Test at 1310nm and 1550nm
The NF-9816 supports 1310 nm and 1550 nm OTDR testing for G.652 single-mode fiber.
Its specified dynamic range is:
1310 nm — 26 dB
1550 nm — 28 dB
Testing at both wavelengths provides additional information about the fiber link.
If a suspicious event appears at the same location during both tests, technicians can investigate that section further.
Differences between the two wavelengths can also provide useful clues about fiber conditions.
Is It Really the Splice?
Not every OTDR loss event automatically represents a bad fusion splice.
Before re-splicing the fiber, consider whether the event could be associated with:
Connector
Mechanical connection
Fiber bend
Cable stress
Patch panel
Other known network component
This is why network documentation is important.
If the suspicious OTDR event occurs at exactly the distance of a known splice enclosure, there is a stronger reason to inspect that splice.
Check from Both Directions When Necessary
For important fiber links, technicians may perform OTDR measurements from both ends of the fiber.
Bidirectional measurements can provide a better understanding of splice loss because OTDR event measurements can be influenced by differences in backscatter characteristics between fiber sections.
A splice may appear differently depending on the direction of measurement.
For more accurate splice-loss assessment, technicians should follow appropriate OTDR testing procedures rather than relying blindly on a single one-direction reading.
What Is a Gainer?
Sometimes an OTDR may show what appears to be a negative-loss event or gainer at a splice.
This does not mean the splice has magically increased optical power.
It can occur when two fiber sections have different backscatter characteristics.
This is another reason why experienced technicians may test a link from both directions when accurate splice-loss assessment is important.
The two directional measurements can then be considered together.
Automatic OTDR for Initial Checking
For routine troubleshooting, technicians can begin with the NF-9816 Automatic OTDR mode.
A practical workflow is:
Step 1: Clean the test connectors.
Step 2: Connect the fiber correctly.
Step 3: Run the OTDR test.
Step 4: Review the Event Map.
Step 5: Identify suspicious loss events.
Step 6: Record the event distance.
Step 7: Compare the distance with splice documentation.
Step 8: Inspect the suspected splice.
This provides a straightforward starting point.
Expert OTDR for Detailed Analysis
If the automatic measurement does not provide enough detail, experienced technicians can use Expert OTDR mode.
Manual adjustment of parameters such as range and pulse width can help when:
Splices are close together
The fiber link is relatively short
The link is relatively long
Events are difficult to distinguish
Detailed trace analysis is required
Selecting suitable OTDR parameters can improve the usefulness of the measurement.
Example: FTTH Fiber Has Excessive Loss
Consider an FTTH distribution fiber with several splicing points.
The optical signal reaches the destination, but received power is lower than expected.
The technician performs an OTDR measurement.
A significant loss event appears approximately 720 metres from the test point.
The splice record shows a distribution splice enclosure around the corresponding location.
The technician can inspect that splice rather than checking every connection along the fiber route.
After repair or re-splicing, the OTDR test should be repeated.
Example: CCTV Fiber Backbone
A CCTV system connects several buildings using a fiber backbone.
The cameras remain online, but communication becomes unstable.
An optical power check indicates lower-than-expected signal level.
OTDR testing identifies an abnormal loss event near a known fiber joint.
This gives the maintenance team a specific location to investigate.
Example: Factory Fiber Network
Industrial facilities may use fiber between:
Production buildings
Control rooms
Warehouses
Utility areas
Remote equipment rooms
If one splice develops excessive loss, replacing the entire cable would be unnecessary.
Locating the suspicious event with an OTDR can help maintenance teams concentrate on the affected joint.
Retest After Re-Splicing
Repair is not the final step.
After a suspicious splice has been repaired, test the fiber again.
Compare:
Before repair
and
After repair
The objective is to confirm that the abnormal loss event has improved and that no additional problems were introduced during the repair process.
Keep OTDR Records
For important fiber infrastructure, consider keeping OTDR records after installation and maintenance.
A baseline trace can be useful later.
If the link develops a problem months or years later, technicians can compare the new measurement with the earlier result.
This can help identify:
New loss events
Changes at existing splices
New bending problems
Fiber damage
Changes in total link condition
OTDR therefore has value for both troubleshooting and preventive maintenance.
NOYAFA NF-9816 for Fiber Splice Testing Malaysia
Looking for an OTDR for fusion splice checking, fiber loss troubleshooting, FTTH maintenance, CCTV fiber networks or industrial fiber maintenance in Malaysia?
Contact MTM Precision Sdn Bhd for enquiries about the NOYAFA NF-9816 and other fiber optic testing instruments.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Enquiries are welcome from Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Kelantan, Terengganu, Sabah and Sarawak.
27 Sep 2026