Fiber or RJ45 Problem? How to Identify Which Side Is Causing the Network Fault Malaysia

Fiber or RJ45 Problem? How to Identify Which Side Is Causing the Network Fault Malaysia

Many modern networks use both fiber optic cable and RJ45 Ethernet cable.

A typical installation may use fiber for the long-distance backbone and copper Ethernet for the final connection to cameras, access points, computers or other network devices.

When communication fails, technicians need to answer an important question:

Is the problem on the fiber backbone or the RJ45 side?

The NOYAFA NF-9816 Multi-Function OTDR Pro combines fiber testing and RJ45 cable functions, making it useful for troubleshooting mixed network infrastructure in Malaysia.

A Typical Mixed Fiber and RJ45 Network

Consider this network:

Main Network Room → Fiber Backbone → Remote Switch → RJ45 Cable → CCTV Camera

If the camera goes offline, the fault could be anywhere along this path.

Possible causes include:

  • Main switch

  • SFP module

  • Fiber patch cord

  • Fiber backbone

  • Remote SFP

  • Remote switch

  • RJ45 cable

  • PoE

  • Camera

Replacing the camera immediately may not solve the actual problem.

Start with the Failure Pattern

Before using a tester, look at what is affected.

One Device Offline

If only one camera, computer or access point is offline while other devices on the same remote switch are working normally, investigate the local side first.

Possible areas include:

  • RJ45 cable

  • Switch port

  • PoE

  • Device power

  • End device

Entire Remote Area Offline

If every device connected to a remote switch becomes unavailable at the same time, investigate the common infrastructure.

Possible areas include:

  • Remote switch power

  • SFP

  • Media converter

  • Fiber backbone

  • Main switch uplink

The pattern of failure can help determine where testing should begin.

Example: Factory Network

A factory has:

Main Office → Fiber → Production Building Switch → RJ45 → Machines

One machine loses network communication.

Other machines connected to the same production-building switch remain online.

This makes a complete fiber backbone failure less likely.

The technician should first investigate:

Machine → RJ45 Cable → Switch Port

Now consider another situation.

Every machine connected to the production-building switch goes offline simultaneously.

The technician should investigate:

Switch Power → Uplink → SFP → Fiber Backbone

Check the RJ45 Side

The NF-9816 provides RJ45 cable functions including:

  • Cable tracing

  • Wire sequence testing

  • Cable length measurement

Its specified RJ45 cable length measurement range is approximately:

1–600 metres

These functions can help technicians investigate the copper side of a mixed network.

What Can Go Wrong with RJ45 Cabling?

Possible RJ45 cable problems include:

  • Open conductor

  • Incorrect wire sequence

  • Poor termination

  • Damaged cable

  • Wrong cable identification

  • Connection problem

The correct diagnostic method depends on the fault and network installation.

Use Cable Tracing

In a cabinet containing many network cables, identifying the correct cable can be difficult.

Cable tracing can assist technicians in locating the corresponding cable before further testing or re-termination.

This can be useful in:

  • CCTV cabinets

  • Offices

  • Server rooms

  • Factory network cabinets

  • Commercial buildings

Correct cable identification reduces unnecessary disconnection.

Check Wire Sequence

Incorrect RJ45 termination can prevent proper communication.

Wire sequence testing can help identify wiring problems after:

  • New installation

  • Connector replacement

  • Cable repair

  • Network modification

This is particularly useful when troubleshooting a newly terminated cable.

What If the RJ45 Side Is Normal?

If the affected devices share a common fiber uplink and the local copper connections appear normal, move upstream.

Check:

  • Remote switch

  • SFP

  • Fiber patch cords

  • Fiber connectors

  • Fiber backbone

This is where the NF-9816's optical functions become useful.

Inspect and Clean Fiber Connectors

Before running an OTDR test:

Inspect → Clean → Connect → Test

Contaminated fiber connectors can introduce additional loss and reflection.

Do not immediately assume the long backbone cable is damaged.

Check Optical Power

The NF-9816 incorporates an Optical Power Meter (OPM) with a specified range of:

-50 dBm to +26 dBm

Optical power testing can help determine whether the received optical level is abnormal for the system.

Remember:

There is no single universal dBm pass/fail value for every network.

The acceptable value depends on:

  • Optical transmitter

  • Receiver sensitivity

  • SFP specification

  • Fiber distance

  • Connector loss

  • Splice loss

  • Network link budget

When Should You Use OTDR?

If the fiber backbone is suspected, OTDR can help determine where significant events are located along the fiber.

The NF-9816 supports OTDR testing at:

1310 nm

and

1550 nm

for G.652 single-mode fiber.

Its specified dynamic range is:

1310 nm — 26 dB

1550 nm — 28 dB

OTDR can help investigate:

  • Unexpected fiber endpoint

  • Fiber break

  • Splice events

  • High-loss events

  • Possible bending

  • Fiber distance

Example: Remote CCTV Cameras Offline

A warehouse has 20 CCTV cameras.

The network arrangement is:

Security Room → Fiber Backbone → Warehouse Switch → RJ45 → 20 Cameras

All 20 cameras suddenly go offline.

Checking every RJ45 camera cable individually is probably not the best first step.

The technician first checks:

Warehouse Switch Power

If normal:

Switch Uplink

Then:

SFP / Fiber Connection

If the fiber is suspected, optical power and OTDR testing can follow.

Example: Only One CCTV Camera Offline

Now suppose 19 cameras remain operational and only Camera 20 is offline.

The common fiber backbone is clearly still carrying network traffic for the other cameras.

Start with:

Camera Power → PoE → RJ45 → Switch Port → Camera

This is a more efficient troubleshooting sequence.

Example: Office Access Point Offline

A remote office uses fiber from the main building to a network switch.

Several Wi-Fi access points connect to the remote switch using RJ45.

Only one access point stops working.

Before testing the fiber backbone, inspect the local copper connection and device.

The failure pattern helps determine where the investigation should begin.

Example: Entire Building Offline

If the complete remote office loses network communication while the switch still has power, the uplink becomes a higher priority.

Check:

  • SFP modules

  • Fiber patch cords

  • Fiber connectors

  • Fiber backbone

  • Main switch port

If required, use OTDR to investigate the physical fiber link.

Use Event Map

The NF-9816 includes an Event Map function.

For example:

0 m — Main Network Room

380 m — Event

720 m — Unexpected Endpoint

If the remote building should be approximately 1.3 km along the fiber route, the unexpected endpoint provides an important clue.

Compare the OTDR distance with the actual installation records.

Fiber Distance Is Not Ground Distance

If the OTDR shows a problem at 720 metres, do not automatically measure 720 metres across the ground.

Fiber routes may include:

  • Cable loops

  • Manholes

  • Vertical runs

  • Indirect ducts

  • Splice enclosures

OTDR measures distance along the optical fiber.

Use route drawings to translate the measurement into a physical inspection area.

Use VFL for Accessible Fiber

The NF-9816 also incorporates a 650 nm Visual Fault Locator (VFL) with a specified output of approximately 10 mW.

For appropriate accessible fiber sections, VFL may assist with:

  • Fiber identification

  • Certain visible faults

  • Sharp bends

  • Short-distance troubleshooting

For long backbone links, OTDR provides more useful distance-to-event information.

Do Not Forget Network Equipment

Even if both RJ45 and fiber cabling appear normal, communication can still fail because of:

  • Switch configuration

  • VLAN settings

  • SFP compatibility

  • Failed switch port

  • Media converter

  • Device configuration

  • Power supply

Cable testing is one part of complete network troubleshooting.

Follow the evidence rather than assuming every communication problem is caused by cabling.

A Practical Fiber vs RJ45 Troubleshooting Method

Use this sequence:

Step 1 — Identify what is offline

One device or many devices?

Step 2 — Find what the affected devices share

Same RJ45 cable?

Same switch?

Same fiber uplink?

Step 3 — Check power and equipment

Confirm switches and network equipment are operating.

Step 4 — Test the local RJ45 side

Trace the cable and check wiring where appropriate.

Step 5 — Check the fiber connection

Inspect and clean connectors.

Step 6 — Check optical power

Compare against the actual system requirements.

Step 7 — Use OTDR

Locate significant fiber events when the backbone is suspected.

Step 8 — Match OTDR distance with the site

Use drawings and route information.

Step 9 — Repair the identified fault

Avoid unnecessary component replacement.

Step 10 — Retest the complete network

Confirm that communication has been restored.

Why an All-in-One Tester Can Be Useful

A technician may arrive at a site without knowing whether the problem is:

Fiber

or

RJ45

A multifunction tester can reduce the need to decide in advance which cable type is responsible.

The NF-9816 combines functions for both sides of the network.

This can be useful for:

  • Network contractors

  • CCTV installers

  • Factory maintenance teams

  • Building maintenance

  • Data centre technicians

  • Fiber contractors

Fiber + RJ45 Preventive Maintenance

The same principle applies to preventive maintenance.

A complete network path may contain:

Fiber Backbone + Network Switch + RJ45 Distribution

Maintaining only one cable type does not provide a complete picture.

Technicians should understand the entire communication path.

Document the Final Fault

After solving the problem, record what actually caused it.

For example:

Fault: CCTV Camera 12 Offline
Cause: Damaged RJ45 cable
Fiber Backbone: Normal

or:

Fault: Entire Warehouse Network Offline
Cause: Fiber break approximately 850 m from main building
RJ45 Distribution: Normal

This creates useful maintenance history for future troubleshooting.

NOYAFA NF-9816 for Fiber and RJ45 Troubleshooting Malaysia

The NF-9816 combines:

  • Automatic OTDR

  • Expert OTDR

  • Event Map

  • 1310/1550 nm OTDR

  • Optical Power Meter

  • Visual Fault Locator

  • Multi-Core Test

  • RJ45 cable tracing

  • RJ45 wire sequence testing

  • RJ45 cable length measurement

This makes it suitable for technicians working with mixed fiber optic and copper Ethernet networks.

Looking for a Fiber and Network Cable Tester in Malaysia?

For fiber troubleshooting, RJ45 cable testing, CCTV networks, factory maintenance, data centre networks, building-to-building fiber and network installation in Malaysia, contact MTM Precision Sdn Bhd.

MTM Precision Sdn Bhd

Showroom & Service Centre:
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.

Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my

Enquiries are welcome from Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Kelantan, Terengganu, Sabah and Sarawak.

27 Sep 2026