UNI-T UT377C Moisture Reading Too High or Unstable Troubleshooting Guide Malaysia

A high or unstable reading from the UNI-T UT377C Pinless Moisture Meter does not always mean that the material is severely wet. The reading may be affected by the selected measurement mode, sensor contact, hidden metal or differences in material density. Before concluding that a wall, floor or wooden panel has a moisture problem, perform several basic checks. Check the Selected Measurement Mode The UT377C provides four modes: Softwood Hardwood Drywall Masonry Using an incorrect mode can produce readings that are difficult to interpret. Choose Softwood or Hardwood mode when checking timber. Use Drywall mode for gypsum boards and lightweight partitions, and Masonry mode for plaster, brick, concrete and similar surfaces. Do not compare readings taken using different modes. Understand Relative Readings In Drywall and Masonry modes, the UT377C displays a relative value from 0 to 99.9. This value is intended for comparison. It is not an absolute moisture-content percentage. A reading of 70 on a wall does not automatically mean the wall contains 70% moisture. The correct method is to compare the suspected area with a dry reference area made from the same material. Possible Cause 1: Hidden Metal Metal behind the surface can influence a pinless moisture meter. Possible hidden objects include: Water pipes Electrical wiring Metal wall studs Screws and nails Reinforcement bars Aluminium insulation Metal corner beads If one small area produces a very high reading while nearby locations remain low, scan around it from several directions. A narrow and repeatable high-reading pattern may be caused by hidden metal rather than moisture. Possible Cause 2: Poor Sensor Contact The rear sensor must sit flat against the test surface. Unstable readings may occur when testing: Rough plaster Curved timber Textured walls Uneven tiles Damaged surfaces Narrow wooden pieces Decorative mouldings The target should be large enough to cover the approximately 50mm × 50mm sensor area. Move the instrument to a flatter section and repeat the measurement. Possible Cause 3: Material Is Too Thin The UT377C is designed for a target thickness of approximately 6mm30mm. If the tested material is too thin, objects or materials behind it may affect the result. Examples include: Thin veneer panels Lightweight partitions Wooden boards placed on metal tables Flooring over damp concrete Thin panels attached to walls Where possible, lift the material away from the supporting surface andmeasure it again. Possible Cause 4: Hands Are Too Close to the Sensor The operator’s hand can influence measurement if it is positioned close to the sensing area. Hold the meter by its designated grip section and keep fingers away from the rear sensor. The UT377C includes an anti-grip interference design, but correct handling remains important for consistent readings. Possible Cause 5: Mixed Construction Materials A wall may contain several different materials, such as plaster, brick, adhesive, waterproofing membrane and metal reinforcement. When the sensor moves from one material to another, the reading can change even when the moisture condition is similar. For meaningful comparison: Measure the same type of material Use the same operating mode Maintain the same sensor position Compare areas with similar construction Take several readings rather than one Avoid comparing a concrete column directly with a lightweight drywall partition. Possible Cause 6: Surface Condensation In humid Malaysian conditions, condensation can develop on cooler walls, pipes and air-conditioned surfaces. A high reading near an air-conditioning unit may be caused by: Condensation on the surface A blocked drain pipe Poor insulation Cold air contacting a humid wall Water leakage from the indoor unit Wipe away visible surface moisture and allow the area to stabilise before measuring again. Possible Cause 7: Moisture Is Not Evenly Distributed Water can travel through cracks, joints and absorbent building materials. The visible stain may not be directly below the source. Moisture may also remain trapped after the leak has been repaired. Scan beyond the visible damaged area and record the pattern of readings. A broad area of consistently higher values is more likely to indicate a moisture condition than one isolated reading. What to Do When the Reading Is High Follow this checking sequence: Confirm the correct measurement mode. Measure a dry reference area. Keep the sensor flat against the surface. Repeat the measurement. Scan surrounding areas. Check for possible pipes, wiring or metal. Record the readings and locations. Inspect for visible water damage. Repeat the test after drying or repair. If the reading remains consistently higher than the reference area, further investigation may be required. What to Do When the Reading Keeps Changing If the reading changes continuously: Clean and dry the sensor surface Check the battery condition Keep the instrument still during measurement Avoid measuring over uneven surfaces Move away from metal objects Keep your hand away from the sensor Test a different area of the same material Restart the meter and select the correct mode You can also test a known dry wooden board to determine whether the instrument produces a stable reading under controlled conditions. When Further Inspection Is Necessary Contact a suitable contractor or building specialist when: Moisture readings remain consistently high Mould or strong damp odour is present Paint continues to peel after repair The wall is soft, swollen or deteriorating Water appears during rain Readings increase near pipes or bathrooms A repaired area does not begin drying Wooden flooring continues to expand or lift The UT377C helps identify suspicious areas, but it does not determine the exact source or repair method. Use the UT377C as a Comparison Tool The most reliable way to use the UNI-T UT377C is to compare multiple readings taken under similar conditions. Focus on patterns, differences and changes over time rather than treating one reading as a final diagnosis. Contact MTM Precision for the UNI-T UT377C or assistance selecting a suitable moisture meter for building inspection, wood testing and maintenance applications in Malaysia. MTM Precision Sdn Bhd Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia Tel: 03-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my

30 Sep 2026