UNI-T UT366A for Cleanroom Positive and Negative Pressure Checks Malaysia
Cleanrooms, laboratories and controlled production areas often use pressure differences to control the direction of air movement between rooms.
A positive-pressure room is designed to push air outward when an opening is created. A negative-pressure room is designed to draw surrounding air inward.
The UNI-T UT366A Digital Manometer can measure the pressure difference between two areas and help facility teams check whether the intended pressure direction is being maintained.
Why Room Differential Pressure Matters
Pressure direction can help control how airborne particles, dust, odours or contaminants move between adjacent spaces.
Positive pressure may be used when the room needs protection from outside contamination.
Negative pressure may be used when air from the room must be contained and directed towards an appropriate exhaust or treatment system.
The required pressure value depends on:
-
The facility design
-
Room classification
-
Internal operating procedure
-
Applicable project requirements
-
Ventilation and exhaust configuration
-
Door and airlock arrangement
The UT366A provides the measurement, but the result must be compared with the correct facility specification.
Positive-Pressure Room
A room is under positive pressure when its internal pressure is higher than the pressure in the adjacent area.
When the door opens, air should generally move from the higher-pressure room towards the lower-pressure area.
Positive pressure may be used in:
-
Clean production areas
-
Electronics assembly rooms
-
Certain laboratories
-
Inspection rooms
-
Controlled packaging areas
-
Data-centre rooms
-
Protected storage areas
A positive reading or green pressure indicator can represent the intended condition, depending on how P1 and P2 are connected.
Negative-Pressure Room
A room is under negative pressure when its internal pressure is lower than the adjacent area.
When the door opens, air should generally move into the room rather than escaping from it.
Negative pressure may be used in:
-
Isolation areas
-
Chemical-handling rooms
-
Dust-generating rooms
-
Odour-control areas
-
Certain laboratories
-
Exhaust-controlled workspaces
A negative reading or red pressure indicator may represent normal operation when the room is intentionally maintained below the reference-area pressure.
Using P1 and P2
The UT366A has two pressure ports that can be used to compare the pressure between two locations.
A typical setup involves:
-
Positioning one pressure connection inside the controlled room.
-
Positioning the second connection in the reference area.
-
Connecting both hoses to P1 and P2.
-
Selecting differential-pressure measurement.
-
Confirming the required pressure unit.
-
Allowing the reading to stabilise.
-
Recording both the value and displayed sign.
If the displayed sign is opposite to what is expected, inspect the connection points. Reversing P1 and P2 will normally reverse the sign.
Keep the Reference Point Stable
The reference point must represent the pressure of the comparison area.
Avoid placing the hose opening:
-
Directly below an air-conditioning grille
-
In front of an exhaust outlet
-
Beside a fan
-
Where people frequently pass
-
Against a wall or obstruction
-
Where outdoor wind can affect the reading
A poor reference location may produce a fluctuating or misleading result.
Door Position Affects the Reading
Opening a door changes the pressure relationship between two rooms.
When recording measurements, note whether the door was:
-
Fully closed
-
Partially open
-
Fully open
-
Moving during the test
For routine monitoring, repeat the measurement using the same door condition and pressure points.
Airlock doors should be tested according to the facility’s approved operating procedure.
Check the Room Under Normal Operation
Before measuring, confirm that:
-
Supply-air systems are operating
-
Exhaust systems are operating
-
Fans are at the normal speed
-
Dampers are in the normal position
-
Access panels are closed
-
Doors are in the required test position
-
Production equipment is operating as intended
-
Pressure hoses are secure and not leaking
A reading taken during shutdown or temporary ventilation changes may not represent normal room performance.
Reasons for Low or Lost Positive Pressure
If a positive-pressure room shows a lower-than-normal differential pressure, possible causes include:
-
Reduced supply airflow
-
Dirty air filter
-
Fan-speed reduction
-
Open door
-
Damaged door seal
-
Unsealed wall or ceiling penetration
-
Excessive exhaust airflow
-
Leaking duct
-
Incorrect damper position
-
Air bypass around the room envelope
Pressure measurement helps identify that a change has occurred, but additional airflow and physical inspection may be required to locate the cause.
Reasons for Weak Negative Pressure
If a negative-pressure room is no longer maintaining the required pressure direction, possible causes include:
-
Exhaust fan problem
-
Blocked exhaust filter
-
Reduced extract airflow
-
Open door
-
Air leakage
-
Excessive supply air
-
Incorrect damper position
-
Pressure-hose connection error
-
Reference-point disturbance
The complete ventilation system should be inspected before changing fan settings.
Pressure Unit Selection
The UT366A supports multiple pressure units, including:
-
kPa
-
mbar
-
bar
-
psi
-
mmHg
-
inH₂O
-
inHg
-
mmH₂O
-
ftH₂O
-
hPa
Select the same unit used in the facility specification or commissioning record. Comparing readings in different units can lead to incorrect conclusions.
Record the Measurement Properly
A useful room-pressure record should include:
-
Date and time
-
Room name or number
-
Reference area
-
P1 location
-
P2 location
-
Pressure unit
-
Measured value
-
Positive or negative sign
-
Door position
-
Supply and exhaust operating status
-
Technician’s name
-
Corrective action, if required
Taking readings at the same test points improves the value of long-term trend records.
UT366A Functions for Room-Pressure Checks
Useful UT366A functions include:
-
Independent P1 and P2 measurement
-
Differential-pressure measurement
-
Positive and negative pressure LED indicators
-
MAX, MIN and AVG recording
-
HOLD function
-
Unit memory
-
Backlit display
-
Magnetic hook
-
Automatic power-off
-
Low-battery indication
The instrument has a pressure range of ±15.00 kPa and a specified accuracy of ±0.5% full scale at 25°C.
When Should the Instrument Be Checked?
Further checking may be required when:
-
The display does not return near zero
-
Readings fluctuate with both pressure points stable
-
The result differs significantly from another verified instrument
-
A pressure port is damaged
-
Moisture entered the pressure connection
-
The instrument was dropped
-
The reading remains inconsistent after replacing the hoses and batteries
A calibration comparison verifies measurement performance. It does not repair a damaged sensor or pressure port.
Enquire About Room Differential-Pressure Measurement
For assistance selecting the UNI-T UT366A for cleanroom, laboratory or controlled-room pressure checks, contact MTM Precision with the required pressure range, unit and intended measurement points.