UNI-T UT306C for Food Surface Temperature and Cold Chain Checking Malaysia

UNI-T UT306C for Food Surface Temperature and Cold Chain Checking Malaysia The UNI-T UT306C Infrared Thermometer enables food operators to perform fast, non-contact surface-temperature checks without touching the product. It can support initial screening during food receiving, storage, preparation, display and delivery. Its −50°C to 500°C range, circular laser, 12:1 distance-to-spot ratio and adjustable emissivity make it suitable for checking many food and packaging surfaces. However, the UT306C measures surface temperature only. It cannot confirm the internal temperature of food and should not replace a penetration probe when core temperature verification is required. Food Applications for the UT306C The UT306C can assist with surface checks on: Chilled food packaging Frozen food packaging Delivered food cartons Food-storage containers Refrigerated display surfaces Cold-room panels Freezer shelves Food preparation surfaces Cooking-equipment surfaces Hot-holding containers Packaging lines Food transport boxes Its non-contact operation allows multiple items to be screened quickly. What Does the UT306C Measure? The UT306C detects infrared energy emitted from the target surface. When aimed at packaged food, it measures the surface of the packaging—not necessarily the food inside. When aimed at exposed food, it measures the visible outer surface—not the centre of the product. Surface and internal temperatures can differ because of: Product thickness Packaging material Storage duration Airflow Recent removal from refrigeration Cooking method Thawing Heat transfer Sunlight Transport conditions Use a suitable penetration probe when internal temperature must be confirmed. Infrared Thermometer vs Food Probe The UT306C and a food probe perform different functions. Inspection RequirementUT306C Infrared ThermometerPenetration ProbeSurface-temperature screeningSuitablePossible but slowerInternal food temperatureNot suitableSuitableNon-contact checkingYesNoRapid screening of many itemsSuitableSlowerChecking through packagingMeasures packaging surfaceRequires access to productCore cooking-temperature verificationNot suitableSuitableFrozen package surface checkSuitableApplication-dependent A practical workflow is to use the UT306C for fast screening and a probe for verification when a reading appears unusual or internal temperature is required. Receiving Chilled and Frozen Food During receiving, operators can use the UT306C to screen the surface temperature of packaging before accepting or transferring products into storage. A basic receiving check may include: Inspect the delivery vehicle and product condition. Check for damaged or wet packaging. Select products from different parts of the delivery. Measure clean, representative package surfaces. Note any items with unusual readings. Verify selected products using the required method. Record the delivery and inspection results. A package surface can warm quickly during unloading. The infrared reading should be interpreted together with delivery time, packaging, vehicle conditions and the company’s food-safety procedure. Checking Products in a Delivery Carton The outer carton temperature may not represent the products inside. For a better initial assessment: Open the carton according to the receiving procedure Select a package from near the outer section Check another package from the centre Compare the surface readings Use a probe if internal verification is necessary Minimise the time that chilled products remain outside storage Do not assume that one reading represents the entire delivery. Cold-Room and Freezer Inspection The UT306C can also be used to check the surfaces of: Cold-room walls Ceiling panels Floor sections Door surfaces Door seals Shelving Evaporator housings Stored packaging A warmer area around a door or panel joint may justify further inspection. Possible causes include: Frequent door opening Damaged seals Air leakage Insulation problems Nearby heat sources Product loading patterns Airflow obstruction An infrared thermometer cannot measure the cold-room air temperature directly. Use a suitable air-temperature instrument or data logger for continuous room monitoring. Can the UT306C Measure Refrigerator Air Temperature? No. The UT306C measures the surface at which it is aimed. If it is pointed inside a refrigerator, it may measure: An internal wall A shelf A food package The evaporator surface The back panel It does not directly measure the surrounding air. For air-temperature measurement, use a suitable thermometer, probe or temperature data logger. Checking Refrigerated Display Cabinets The UT306C can support spot checks on: Display shelves Product-package surfaces Cabinet walls Door surfaces Accessible cooling surfaces Check products at different positions because temperature conditions may vary between: Front and rear Top and bottom Centre and sides Areas near doors Areas close to the cooling outlet Surface readings should be supported by the cabinet’s air-temperature monitoring and the company’s required food-safety procedure. Hot Food and Heated Surface Checking The UT306C can rapidly screen the surface of hot food, trays and heated containers. It may help users identify items that appear cooler than others during: Food preparation Hot holding Buffet service Packaging Dispatch Delivery preparation A hot surface does not confirm that the centre of the food has reached the required temperature. Use a suitable sanitised penetration probe when internal cooking or holding temperature must be verified. Circular Laser Targeting The circular laser helps the user aim at the intended surface area. It is useful when checking: Individual food packages Containers Trays Storage boxes Display surfaces Equipment panels The laser does not measure temperature and should not be directed toward anyone’s eyes. Food operators should also ensure that laser use is permitted within the work area and does not create confusion or unsafe behaviour. Understanding the 12:1 Distance-to-Spot Ratio The UT306C has a 12:1 distance-to-spot ratio. Approximate spot sizes include: At 120mm, the spot is about 10mm At 600mm, the spot is about 50mm At 1,200mm, the spot is about 100mm The package or food surface should be larger than the measurement spot. If the target is too small, the UT306C may also measure the tray, shelf or background. Move closer when checking smaller packages, provided that the instrument remains protected from food contamination, moisture and excessive heat. Avoid Measuring Transparent Packaging Incorrectly Clear plastic film and transparent covers can create misleading readings. The UT306C may measure: The plastic surface Reflected infrared energy Condensation on the packaging A combination of packaging and nearby surfaces The visible food behind transparent packaging is not necessarily the surface being measured. For critical verification, use the appropriate probe method according to the organisation’s food-safety procedure. Check Packaging Material and Emissivity The UT306C allows emissivity adjustment from 0.10 to 1.00. Food packaging may include: Cardboard Plastic Paper Aluminium foil Metal containers Transparent film Printed labels Coated surfaces Cardboard, paper and many non-reflective plastic surfaces are generally easier to measure. Shiny foil and reflective metal packaging can produce unreliable results because they reflect infrared energy from the surrounding environment. Whenever possible, measure a non-reflective and representative area. Condensation Can Affect the Reading Chilled and frozen products may develop condensation when moved into a warm, humid environment. The UT306C may then measure the temperature of the moisture layer rather than the dry package surface. Condensation may also form on the thermometer if it is moved repeatedly between a cold room and a warm loading area. Allow the instrument to stabilise and keep the sensor window dry. Checking Frozen Products The UT306C can screen the surface of frozen-product packaging. A warmer-than-expected package surface may justify further checks, especially when combined with: Softened product Damaged packaging Water marks Ice melting Product deformation Delivery delays Poor vehicle conditions A single surface reading cannot confirm whether the product has thawed internally or whether the cold chain has been broken. Review the complete receiving record and use the required verification method. Checking Food Preparation Surfaces The UT306C can check surface temperature on suitable areas such as: Worktops Trays Equipment housings Storage containers Heated plates Cooling surfaces It does not confirm cleanliness, hygiene or microbiological safety. Temperature measurement and hygiene inspection are separate processes. High and Low Temperature Alarm The UT306C includes audible high and low temperature alarms. This feature can help operators screen repeated surfaces according to established internal limits. Before using the alarm: Confirm the correct surface is being measured Set the appropriate temperature unit Select suitable emissivity Define limits based on the organisation’s procedure Check the target size and distance Verify unusual readings with the required method Alarm settings should not be treated as universal food-safety limits. MAX and MIN Functions The UT306C provides: MAX for the highest detected temperature MIN for the lowest detected temperature AVG for the average temperature DIF for the difference between maximum and minimum readings MIN mode may help identify the coldest point across a frozen-package surface. MAX mode may help identify a warmer area across chilled packaging or heated equipment. These functions describe surface readings during the scan and do not represent the internal food temperature. Common Food Measurement Mistakes Common mistakes include: Treating surface temperature as core temperature Measuring only the outer delivery carton Measuring through transparent film Measuring shiny foil packaging Standing too far from a small package Ignoring condensation Measuring different packaging materials without adjusting emissivity Assuming refrigerator air temperature from a wall reading Checking only one product in a large delivery Failing to verify unusual readings with a probe Using general temperature limits without following the organisation’s procedure Understanding these limitations helps prevent incorrect acceptance or rejection decisions. Recommended Screening and Verification Process A practical process is: Use the UT306C to screen multiple product surfaces. Identify packages with unusual readings. Check packaging condition and delivery history. Select representative items for verification. Use a suitable probe when internal temperature is required. Record the result and action taken. Follow the organisation’s food-safety procedure. The UT306C is most effective as the first stage of inspection. Cleaning and Hygiene Considerations Although the UT306C operates without touching food, it may still be handled in food-processing areas. Users should: Keep the instrument clean and dry Avoid placing it on food-contact surfaces Protect it from splashes Follow the facility’s hygiene procedure Avoid aggressive cleaning chemicals Keep the infrared sensor window clean Store it away from food contamination Do not immerse the thermometer in water. Who Can Use the UT306C for Food Checking? The UT306C may be useful for: Food receiving teams Cold-room operators Restaurants and kitchens Food-processing facilities Supermarkets Frozen-food distributors Catering companies Warehouses Cold-chain transport operators Quality-control personnel Users should be trained to distinguish between surface screening and internal temperature verification. Enquire About UNI-T UT306C in Malaysia For assistance selecting an infrared thermometer for food-surface, cold-room or cold-chain checking, contact MTM Precision. You may WhatsApp us with a photo of the product, packaging and intended measuring point for an initial recommendation. MTM Precision Sdn Bhd Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia Tel: 03-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my

01 Oct 2026