How to Use the Oscilloscope on FNIRSI DSO-TC3 Plus Malaysia

How to Use the Oscilloscope on FNIRSI DSO-TC3 Plus Malaysia

The FNIRSI DSO-TC3 Plus is more than a transistor and component tester.

It also includes a digital oscilloscope, allowing electronics technicians to view how an electrical signal changes over time.

This can be useful when troubleshooting:

PCB circuits

PWM signals

Sensor outputs

Audio signals

Power supply ripple

Control signals

Low-frequency electronics

For users in Malaysia who are new to oscilloscopes, understanding a few basic settings can make waveform troubleshooting much easier.

What Does an Oscilloscope Actually Show?

A digital multimeter normally gives you a number.

For example:

5.02 V

An oscilloscope provides different information.

It shows the waveform.

Instead of only knowing the voltage, you may be able to see whether the signal is:

Steady

Pulsing

Oscillating

Noisy

Distorted

Unstable

This is why oscilloscopes are so useful for electronics troubleshooting.

Before Connecting the Probe

Do not connect an oscilloscope to an unknown circuit before understanding:

The expected voltage

The circuit reference

The probe configuration

The instrument input limits

Whether the circuit is isolated

This is especially important when working with:

AC mains

Switching power supplies

Inverters

UPS systems

Motor drives

High-voltage circuits

A small handheld oscilloscope should never be assumed to be safe for direct connection to every electrical circuit.

Step 1: Start with a Known Signal

If you are learning how to use the DSO-TC3 Plus oscilloscope, begin with a known low-voltage signal rather than an unknown industrial circuit.

This makes it easier to understand:

Voltage scale

Time base

Trigger

Frequency

Waveform shape

Once you understand these controls, you can move on to suitable troubleshooting applications.

Step 2: Connect the Probe Correctly

Connect the oscilloscope probe according to the instrument instructions.

The measurement requires a signal connection and the correct reference connection.

Incorrect probe connection can produce:

No waveform

Unstable waveform

Incorrect amplitude

Excessive noise

or potentially create an unsafe condition.

Always understand what the probe reference is connected to before making the measurement.

Step 3: Understand the Voltage Scale

The vertical scale determines how the signal is displayed vertically on the screen.

If the scale is too small, the waveform may extend beyond the display.

If the scale is too large, a small signal may appear almost flat.

The objective is to adjust the scale so that the waveform occupies a useful portion of the screen.

For example, when checking a low-voltage signal, choose a range appropriate to the expected amplitude.

Step 4: Understand the Time Base

The horizontal axis represents time.

The time-base setting determines how much time is displayed across the screen.

If the time base is not suitable, a repetitive signal may look:

Compressed

Stretched

Unrecognisable

or almost like a straight line.

Adjust the time base until several useful waveform cycles can be seen clearly.

Step 5: Adjust the Trigger

Triggering helps stabilise repetitive waveforms on the screen.

Without suitable triggering, the waveform may appear to move continuously across the display.

For a repeating waveform, adjust the trigger settings so the oscilloscope begins displaying the waveform at a consistent point.

This makes it much easier to evaluate:

Shape

Frequency

Amplitude

Timing

Why Does My Waveform Keep Moving?

A moving or rolling waveform does not automatically indicate a faulty circuit.

Possible causes include:

Incorrect trigger level

Incorrect trigger mode

Time base not suitable

Signal is unstable

Poor probe connection

Excessive electrical noise

Before concluding that the circuit has a problem, check the oscilloscope settings.

How to Check a Square Wave

Square waves are common in electronics.

They may appear in:

PWM circuits

Clock circuits

Digital control

Signal generators

Microcontroller outputs

When viewing a suitable square wave, you may investigate characteristics such as:

Amplitude

Frequency

Duty cycle

Waveform stability

If the expected square wave is missing or distorted, further troubleshooting may be required.

How to Check PWM Signals

PWM means Pulse Width Modulation.

PWM is widely used for controlling:

Motors

LED brightness

Power converters

Fans

Actuators

Power electronics

A multimeter may provide only a numerical reading that does not clearly explain the PWM behaviour.

An oscilloscope allows you to see the actual pulse waveform.

This can help determine whether the control circuit is producing a signal.

How to Check a Sensor Output

Some sensors produce electrical signals that change with:

Temperature

Pressure

Position

Speed

Light

Movement

Depending on the sensor type and signal characteristics, an oscilloscope may help technicians observe how the output changes.

However, always confirm the expected sensor signal and voltage before connecting the instrument.

How to Check Power Supply Ripple

A DC power supply should ideally provide a stable output, but real power supplies contain some ripple and noise.

An oscilloscope can help investigate variations on a DC supply.

Excessive ripple may be associated with issues such as:

Deteriorated capacitors

Filtering problems

Switching problems

Excessive load

However, waveform interpretation requires care.

Probe technique and oscilloscope settings can also introduce apparent noise.

Can DSO-TC3 Plus Be Used for SMPS Repair?

The DSO-TC3 Plus may support some basic low-voltage waveform troubleshooting, but switching power supply repair requires extra caution.

An SMPS can contain hazardous voltages on its primary side.

Do not assume that because the DSO-TC3 Plus is portable, it can be connected directly to any point in a mains-powered circuit.

For professional power-electronics troubleshooting, appropriate oscilloscope equipment, probes, isolation strategy and safety procedures may be required.

What Does Frequency Mean?

Frequency describes how many cycles of a repeating waveform occur each second.

It is measured in hertz (Hz).

For example:

1 kHz = 1,000 cycles per second

When troubleshooting a circuit, comparing the measured frequency with the expected frequency can help identify abnormal operation.

What Is Amplitude?

Amplitude describes the size of the signal.

When using an oscilloscope, pay attention to how voltage is represented on the vertical axis.

Depending on the measurement, you may encounter terms such as:

Peak voltage

Peak-to-peak voltage

Average voltage

RMS voltage

These are not interchangeable.

Make sure you understand which measurement is relevant to your application.

Why Does the Waveform Look Noisy?

Noise can come from the circuit, but it can also come from the measurement setup.

Possible causes include:

Long probe connections

Poor grounding

Nearby switching equipment

Electromagnetic interference

Incorrect probe technique

Power supply noise

Actual circuit instability

Before diagnosing the PCB, make sure the measurement setup itself is not causing the problem.

DSO-TC3 Plus vs Multimeter

A multimeter and oscilloscope answer different questions.

A multimeter may tell you:

“The voltage is approximately 5 V.”

An oscilloscope may show:

“The signal changes between two voltage levels thousands of times per second.”

For electronics troubleshooting, both types of information can be valuable.

The DSO-TC3 Plus should therefore complement rather than completely replace a good digital multimeter.

Why the DSO-TC3 Plus Is Useful for Repair Work

The main advantage is that after viewing a waveform, the technician can also use the same portable instrument for supported component testing.

For example:

Waveform is abnormal

↓

Power down the PCB

↓

Remove suspected MOSFET

↓

Test MOSFET

↓

Check capacitor

↓

Check resistor or inductor

This is where the oscilloscope + component tester combination becomes useful.

When Should You Use a Bench Oscilloscope Instead?

The DSO-TC3 Plus is intended for relatively basic portable electronics testing.

A professional bench oscilloscope may be more appropriate when you require:

Higher bandwidth

Higher sampling performance

Multiple channels

Advanced triggering

More detailed waveform analysis

Professional power-electronics measurements

Always select an oscilloscope according to the frequency, voltage, signal type and measurement requirements of the application.

Basic Oscilloscope Troubleshooting Workflow

A practical approach is:

1. Understand the expected signal.

2. Confirm that the signal is within the instrument's capability.

3. Connect the probe correctly.

4. Select an appropriate voltage scale.

5. Adjust the time base.

6. Set the trigger for a stable display.

7. Observe waveform shape and amplitude.

8. Check frequency where relevant.

9. Compare the result with the expected circuit behaviour.

10. Continue component-level troubleshooting if necessary.

The key is not simply seeing a waveform.

The objective is understanding whether the waveform makes sense for that point in the circuit.

FNIRSI DSO-TC3 Plus Malaysia

MTM Precision supplies FNIRSI electronic testing instruments in Malaysia for electronics repair, PCB troubleshooting, maintenance, education and component testing.

Customers from Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak may contact us for product enquiries and availability.

If you are unsure whether the FNIRSI DSO-TC3 Plus oscilloscope is suitable for the signal you need to measure, send us a photo of the PCB, equipment or application through WhatsApp and tell us the expected voltage and frequency.

MTM Precision Sdn Bhd

Showroom & Service Centre:
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.

Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my

05 Oct 2026