How to Check Power Supply Ripple with FNIRSI 1014D Oscilloscope Malaysia
How to Check Power Supply Ripple with FNIRSI 1014D Oscilloscope Malaysia
Your multimeter shows 12V DC.
Does that mean the power supply is definitely good?
Not necessarily.
A digital multimeter can tell you the approximate DC voltage, but it may not clearly show ripple, noise, spikes or other fast changes riding on the power supply output.
For electronics troubleshooting, an oscilloscope such as the FNIRSI 1014D can help you see what the DC supply actually looks like over time.
What Is Power Supply Ripple?
Ideally, a DC power supply should provide a stable DC output.
For example:
12V DC
In a real power supply, a small AC component may remain on top of the DC voltage.
This variation is commonly referred to as ripple.
The amount and waveform depend on the power supply design, load and operating condition.
Excessive ripple may indicate a problem or contribute to unstable circuit operation.
Why Doesn't a Multimeter Tell the Whole Story?
Suppose you measure a power supply and get:
Multimeter: 12.1V DC
The reading appears normal.
But the equipment connected to the power supply:
-
Resets randomly
-
Produces noise
-
Operates intermittently
-
Becomes unstable under load
-
Shows display problems
-
Malfunctions during startup
The average DC voltage alone may not explain the problem.
An oscilloscope allows you to examine how that voltage changes with time.
What Can the FNIRSI 1014D Show?
When properly connected and configured, an oscilloscope can help reveal:
Ripple
Electrical noise
Periodic disturbances
Voltage fluctuations
Unexpected spikes
Oscillation
Intermittent voltage drops
Instead of seeing only one number, you can see the waveform.
Step 1: Check the DC Voltage First
Before using an oscilloscope, it is often useful to start with a digital multimeter.
Check whether the basic DC voltage is approximately correct.
For example:
Expected: 12V DC
Measured: 12.0V DC
If the voltage is significantly incorrect, you already have useful troubleshooting information.
If the voltage appears correct but the equipment still behaves abnormally, waveform analysis may be the next step.
Step 2: Understand the Grounding
Before connecting the FNIRSI 1014D, understand the circuit and grounding arrangement.
This is especially important.
Do not simply attach the oscilloscope ground clip to an unknown point.
Incorrect grounding can:
-
Short part of the circuit
-
Damage the PCB
-
Damage the oscilloscope
-
Create an electrical hazard
This is particularly important for mains-connected and non-isolated power supplies.
Step 3: Connect to a Suitable Low-Voltage DC Output
For an appropriate low-voltage circuit, connect the oscilloscope probe according to the equipment's measurement requirements.
The probe tip measures the selected point while the reference connection must be connected correctly.
Always verify:
Voltage level
Probe rating
Oscilloscope input rating
Ground reference
before making the measurement.
Step 4: Observe the DC Waveform
Start by observing the overall DC output.
You may see a relatively stable line representing the DC voltage.
If the waveform moves significantly, contains repeated disturbances or shows unexpected behaviour, further investigation may be required.
The correct waveform depends on the type of power supply and operating conditions.
Step 5: Look More Closely at the Ripple
Small ripple can be difficult to see when the oscilloscope is displaying the entire DC voltage range.
Appropriate vertical scale and coupling settings may help make the smaller AC variation more visible.
When checking small ripple signals, measurement technique matters.
Poor probing can introduce additional noise and make the waveform look worse than it really is.
Why Probe Technique Matters
A long ground connection can pick up unwanted electrical noise.
This can be especially noticeable when measuring small ripple signals in switching circuits.
Therefore, an ugly-looking waveform does not automatically mean the power supply is faulty.
Consider:
-
Probe connection
-
Ground lead length
-
Nearby switching noise
-
Measurement point
-
Oscilloscope settings
-
Bandwidth requirements
Good measurement technique is important before making a diagnosis.
Compare No-Load and Loaded Conditions
Some power supplies appear normal when there is little load but become unstable when the equipment starts operating.
If the test can be performed safely, compare the power supply under different operating conditions.
You may find:
No load → Stable
Normal load → Increased ripple
or:
Startup → Voltage drops
Normal operation → Voltage recovers
This type of behaviour can provide useful troubleshooting information.
What Can Cause Excessive Ripple?
Depending on the circuit, excessive ripple or unstable output may be associated with issues such as:
-
Ageing capacitors
-
Faulty filtering components
-
Poor regulation
-
Overloading
-
Switching problems
-
Rectification problems
-
Connection problems
-
Abnormal load conditions
However, the oscilloscope waveform alone does not automatically identify the failed component.
Further testing is normally required.
Using Two Channels for Power Supply Troubleshooting
The dual-channel capability of the FNIRSI 1014D can be useful when you need to compare two related signals.
For example:
CH1 → Power supply output
CH2 → Control or output signal
You may then observe whether a disturbance on the supply occurs at the same time as abnormal circuit behaviour.
Another application could be comparing two different low-voltage supply rails.
This can provide additional information when troubleshooting complex electronic PCBs.
Can FNIRSI 1014D Check Switching Power Supplies?
It can be useful for appropriate measurements on suitable low-voltage sections, but switching power supplies require extra care.
Do not assume that every point inside a switching power supply is safe to probe.
Some sections may be directly related to hazardous mains voltage.
For advanced power-electronics measurements, appropriate differential probes, isolation methods or higher-category test equipment may be required.
The standard oscilloscope probe should never be treated as a universal high-voltage measurement solution.
Multimeter vs Oscilloscope for Power Supply Testing
A practical troubleshooting workflow may be:
Multimeter → Is the basic DC voltage correct?
Oscilloscope → Is the voltage clean and stable over time?
These two instruments complement each other.
For electronics repair technicians, using both can provide a much clearer picture of power supply condition.
Where Is This Useful?
Power supply waveform checking may be relevant to:
-
Electronic PCBs
-
Control boards
-
DC adapters
-
Embedded systems
-
Audio electronics
-
LED electronics
-
Communication equipment
-
Laboratory projects
-
Electronics repair
-
Technical education
The exact measurement method depends on the circuit being tested.
FNIRSI 1014D for Electronics Troubleshooting
The FNIRSI 1014D provides a useful step beyond basic multimeter testing.
Instead of asking only:
“Is there 12V?”
you can also investigate:
“Is that 12V stable?”
“Is there excessive ripple?”
“Does the voltage drop when the circuit operates?”
“Are there unexpected disturbances?”
These questions can be important when troubleshooting electronic equipment.
Looking for FNIRSI 1014D in Malaysia?
For enquiries about the FNIRSI 1014D Oscilloscope with Signal Generator in Malaysia, contact MTM Precision Sdn Bhd.
If you are unsure whether the FNIRSI 1014D is suitable for your power supply or PCB application, WhatsApp us a photo of the equipment and the point you intend to measure.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers across Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
05 Oct 2026