What Is X-Y Mode on FNIRSI 1014D Oscilloscope? Lissajous Guide Malaysia
What Is X-Y Mode on FNIRSI 1014D Oscilloscope? Lissajous Guide Malaysia
Most oscilloscope measurements display:
Voltage vs Time
But the FNIRSI 1014D also provides an X-Y display mode, which allows two signals to be compared in a different way.
Instead of using time as the horizontal axis, X-Y mode uses one input signal to control one axis and another signal to control the other.
This can produce patterns known as Lissajous figures.
For electronics students, technicians and training laboratories, X-Y mode provides a useful way to understand frequency and phase relationships between two signals.
What Is Normal Oscilloscope Mode?
In normal oscilloscope operation, the horizontal axis represents:
Time
and the vertical axis represents:
Voltage
If you connect a sine wave, you see the familiar waveform moving from left to right across the screen.
With a dual-channel oscilloscope such as the FNIRSI 1014D, CH1 and CH2 can both be displayed against the same time axis.
This is the standard way most users operate an oscilloscope.
What Changes in X-Y Mode?
In X-Y mode, the oscilloscope no longer uses its normal time-base display in the same way.
Instead, one channel influences the horizontal position while another influences the vertical position.
Conceptually:
X Axis → One Channel
Y Axis → Another Channel
The resulting pattern depends on the relationship between the two signals.
What Is a Lissajous Pattern?
A Lissajous pattern is the shape created when two periodic signals are plotted against each other.
Depending on their:
Frequency
Phase
Amplitude
the display can produce different shapes.
You may see patterns resembling:
-
A diagonal line
-
An ellipse
-
A circle
-
A figure-eight
-
More complex looping patterns
These patterns can provide information about how the two signals relate to each other.
Simple Example: Same Frequency and Same Phase
Suppose CH1 and CH2 receive suitable sine waves with:
The same frequency
and
The same phase
In an idealized setup with suitable scaling, the X-Y display can approach a diagonal line.
Both signals rise and fall together.
This shows a strong relationship between the two signals.
What Happens When Phase Changes?
Now keep the frequencies the same but change the phase relationship.
The pattern can change from a line into an ellipse.
Under appropriate conditions, a larger phase difference can produce a more circular-looking pattern.
This gives students a visual way to understand:
Phase difference
instead of only reading it as a number.
Why Is Phase Important?
Two signals can have exactly the same frequency but not reach their peaks at the same time.
This difference is described as phase.
Phase relationships matter in many areas of electronics, including:
-
Amplifiers
-
Filters
-
AC circuits
-
Oscillators
-
Signal processing
-
Audio circuits
-
Control systems
X-Y mode provides one method of visualizing these relationships.
X-Y Mode for Electronics Education
One of the strongest uses of X-Y mode is education.
Students often learn about phase mathematically.
For example:
0°
45°
90°
But numbers alone may be difficult to visualize.
By applying two suitable sine waves to a dual-channel oscilloscope and using X-Y mode, students can see how changing phase affects the displayed pattern.
This turns an abstract concept into something visible.
X-Y Mode and Frequency Comparison
Lissajous patterns can also be used to investigate frequency relationships.
If the two signals have different but related frequencies, more complex patterns may appear.
Historically, this technique was used to compare an unknown frequency against a known reference frequency.
The shape and number of loops can provide information about their frequency ratio.
Can FNIRSI 1014D Measure Frequency Normally?
Yes.
For most routine electronics troubleshooting, you do not need to use Lissajous patterns just to determine frequency.
Normal oscilloscope measurement is generally much more convenient.
X-Y mode is particularly useful when you want to:
Visualize signal relationships
Learn about phase
Perform demonstrations
Study frequency ratios
rather than simply read a frequency value.
Example: Input and Output of a Circuit
Suppose you are testing a circuit that changes the phase of a sine-wave signal.
You could connect:
CH1 → Circuit Input
CH2 → Circuit Output
In normal oscilloscope mode, you can view the two waveforms against time.
Then X-Y mode provides another way to visualize the relationship between them.
This can be useful for basic filter and phase-shift experiments.
X-Y Mode for Filter Experiments
Filters do more than change signal amplitude.
Depending on their design and operating frequency, they can also affect phase.
A basic experiment could use:
Signal Generator → Filter Input
Then:
CH1 → Filter Input
CH2 → Filter Output
Change the test frequency and observe how the relationship between the two signals changes.
This is useful for electronics education and basic circuit analysis.
Why Is the Built-In Signal Generator Useful?
The FNIRSI 1014D includes a built-in signal generator, which makes it useful for basic waveform experiments.
You can provide a known test signal to a suitable circuit and then observe its input and output.
The combination of:
Signal Generator
Dual Channels
X-Y Mode
allows users to perform several educational and troubleshooting experiments from one instrument.
Why Does My X-Y Pattern Look Distorted?
If the expected Lissajous pattern does not look correct, check several factors.
Possible causes include:
Different amplitudes
Frequency instability
Noise
Incorrect channel scaling
Probe problems
Poor grounding
Actual circuit distortion
Signals that are not clean sine waves
The pattern reflects the signals being applied to the oscilloscope.
Amplitude Affects the Shape
If CH1 and CH2 have very different amplitudes, the pattern may appear stretched in one direction.
Adjusting the channel scales appropriately can make the pattern easier to interpret.
However, remember:
Changing display scaling changes how the pattern looks on the screen.
It does not necessarily mean the electrical signal itself has changed.
Frequency Stability Matters
For a stable Lissajous pattern, the frequency relationship between the two signals needs to remain sufficiently stable.
If one frequency continuously changes relative to the other, the pattern may rotate or move.
This is not necessarily an oscilloscope fault.
It may simply reflect the changing relationship between the signals.
Can X-Y Mode Replace a Phase Meter?
Not necessarily.
X-Y mode is useful for:
Visual comparison
Education
Basic phase experiments
Frequency-ratio demonstrations
For precise phase measurements, specialized equipment or more advanced oscilloscope measurement functions may be more appropriate.
The required accuracy determines the correct instrument.
X-Y Mode vs Normal Dual-Channel Display
For most repair work:
Normal dual-channel display is usually easier.
It lets you see exactly when events happen over time.
For example:
CH1 → PWM command
CH2 → Driver response
This is very useful for troubleshooting.
X-Y mode is different.
Its strength is showing the relationship between two continuously varying signals.
Is X-Y Mode Useful for PCB Repair?
Sometimes, but it is not normally the first function a repair technician needs.
For PCB troubleshooting, you will usually start with:
Voltage
Waveform shape
Frequency
PWM
Clock signals
Input/output comparison
X-Y mode becomes useful when the particular circuit requires investigation of signal relationships, phase or certain analogue behaviours.
Good Experiment for New FNIRSI 1014D Users
If you are learning how to use the FNIRSI 1014D, try X-Y mode after becoming comfortable with normal oscilloscope operation.
First learn:
Voltage scale
Time base
Trigger
Frequency
Dual-channel operation
Then move to X-Y mode.
This makes it much easier to understand what the Lissajous pattern represents.
Who Can Benefit from X-Y Mode?
X-Y mode can be useful for:
-
Electronics students
-
Engineering students
-
Technical colleges
-
Electronics training centres
-
Hobby electronics
-
Basic circuit experiments
-
Amplifier and filter learning
-
Signal analysis education
It adds another educational capability to the FNIRSI 1014D beyond normal waveform viewing.
FNIRSI 1014D for Electronics Learning and Troubleshooting
The FNIRSI 1014D combines several useful functions:
Dual-channel waveform observation
Signal generation
FFT frequency analysis
X-Y display
These functions allow users to study electrical signals from several different perspectives.
For beginners, start with normal waveform measurements.
As your skills develop, functions such as FFT and X-Y mode can help you understand more advanced signal behaviour.
Looking for FNIRSI 1014D in Malaysia?
For FNIRSI 1014D Dual-Channel Oscilloscope with Signal Generator enquiries in Malaysia, contact MTM Precision Sdn Bhd.
If you are buying an oscilloscope for electronics training, PCB troubleshooting or laboratory experiments, WhatsApp us your application so we can help determine whether the FNIRSI 1014D is suitable.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers across Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
05 Oct 2026