How Often Should You Check Indoor PM2.5 During Haze Malaysia

How Often Should You Check Indoor PM2.5 During Haze Malaysia


During a haze episode, checking indoor PM2.5 only once may not provide enough information.


Conditions can change when:


Outdoor API rises


Wind direction changes


Rain starts or stops


Windows are opened


People enter or leave


Cooking begins


An air purifier is switched on


Homes, schools and offices in Banting, Klang, Shah Alam, Kuala Lumpur and other affected areas should monitor according to how the room is used rather than checking randomly.


Is One PM2.5 Reading Enough?


No.


A single reading is only a snapshot of the condition around the monitor at that moment.


It does not show:


- Whether PM2.5 is increasing or decreasing

- Whether the air purifier is effective

- Whether smoke enters when doors open

- Whether one room is cleaner than another

- Whether morning and evening conditions differ

- Whether indoor activities are producing particles


Repeated measurements provide a clearer trend.


Basic Schedule for a Home


For simple household monitoring, check at least:


Morning


Check the bedroom and living room before opening windows or external doors.


This provides a reference for overnight conditions.


Afternoon


Outdoor conditions and household activities may have changed.


Check again after:


- Cooking

- Cleaning

- Opening the main door

- Operating the air purifier

- Changes in outdoor haze


Evening


Check the bedroom before sleeping, especially if the room was unoccupied or the door remained open during the day.


A simple morning, afternoon and evening schedule can provide more useful information than frequent random checks.


When Should You Check More Frequently?


Additional measurements may be useful when:


- Outdoor API changes significantly

- Smoke becomes visible

- A burning smell enters the building

- Windows or doors were left open

- The air purifier was switched off

- The purifier filter was replaced

- Cooking or cleaning caused a sudden increase

- The monitor was moved to another room

- The building ventilation system changed

- Employees or occupants report a change in conditions


Record what happened before the reading changed.


Monitoring Schedule for an Office


An office may check:


Before Employees Arrive


This establishes the condition before normal occupancy.


Mid-Morning


Check after employees have entered and the air-conditioning system has been operating.


During Peak Occupancy


Meeting rooms and training rooms may change quickly when several people occupy the space.


If the monitor also measures CO₂, observe both parameters separately.


After Lunch


External doors, lifts, corridors and pantry activities may influence the reading.


Before the Office Closes


This final reading helps management understand whether conditions improved or worsened throughout the day.


Monitoring Schedule for Schools


Schools and childcare centres may check:


- Before students enter

- During the first occupied session

- Before outdoor activities

- After doors or windows are opened

- After operating air purification

- Before afternoon classes

- When outdoor haze visibly worsens


Do not rely only on a monitor placed in the office.


Classrooms near roads, open corridors or drop-off areas may record different conditions.


Monitoring Schedule for Factories and Warehouses


Factories should measure according to zones and activities.


Useful times include:


- Before the production shift

- After external doors open

- During loading activity

- While major equipment operates

- During lunch or rest periods

- After air filtration is activated

- Before the end of the shift


Record whether the particles may come from outdoor haze or an internal process.


A general PM2.5 monitor supports screening and trend comparison. It does not replace occupational dust sampling or process-specific measurement.


How Long Should You Observe the Monitor?


Avoid recording only the first number displayed immediately after switching on or moving the instrument.


Allow the monitor to respond to the new environment.


The required stabilisation time depends on the instrument, airflow and how different the new location is from the previous one.


When comparing rooms:


- Use the same monitor

- Use a similar measurement height

- Keep the instrument away from vents

- Do not block the air inlet

- Record after the reading begins to stabilise

- Use the same method at every location


What Should Be Recorded?


A practical PM2.5 record may include:


Item Information


Date and time When the measurement was taken

Location Bedroom, office, classroom or factory zone

PM2.5 reading Displayed particle concentration

Outdoor API Latest official regional condition

Doors and windows Open or closed

Air purifier On, off or operating speed

Air-conditioning On or off

Occupancy Approximate number of people

Activity Cooking, cleaning, production or loading

Remarks Smoke smell, rain or unusual event



A short, consistent record is more useful than a complicated form that employees do not complete.


Continuous Monitoring or Manual Spot Checks?


Manual Spot Checks Are Suitable When:


- The monitor is shared between rooms

- Only basic comparisons are required

- The premises are small

- Users can follow a consistent schedule

- Historical data is not essential


Continuous Monitoring Is More Suitable When:


- Conditions change frequently

- The room is occupied for long periods

- Management needs trend records

- Filtration performance must be reviewed

- A critical room requires regular observation


Select the monitoring method according to the application rather than assuming continuous monitoring is always necessary.


Do Not React to Every Small Change


PM2.5 readings may fluctuate because particles and air are constantly moving.


Before taking action, ask:


- Is the increase sustained?

- Did someone open a door?

- Did cooking or cleaning begin?

- Was the monitor moved?

- Did the air purifier stop?

- Did outdoor haze worsen?


Look for repeatable patterns and consistent trends.


Choosing a Monitor for Repeated Checking


For simple haze monitoring, prioritise:


- PM2.5 measurement

- Clear display

- Portable design

- Convenient power arrangement

- Easy operation


A multi-parameter monitor may be considered when users also need:


- CO₂

- PM10

- TVOC

- Formaldehyde

- Temperature

- Humidity


MTM Precision supplies Temtop air-quality monitors for homes, schools, offices, factories and other workplaces.


Customers may WhatsApp us their intended monitoring schedule, required parameters and number of locations for suitable model selection.


MTM Precision Sdn Bhd

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

06 Oct 2026