FNIRSI LCR-ST1 Inductor Testing Guide Malaysia: How to Measure SMD Coils and Inductance
FNIRSI LCR-ST1 Inductor Testing Guide Malaysia: How to Measure SMD Coils and Inductance
Inductor testing is an important part of PCB troubleshooting, switching power supply repair and industrial electronic maintenance.
Inductors are widely used in electronic circuits for energy storage, filtering and electromagnetic interference reduction.
The FNIRSI LCR-ST1 LCR Bridge Tweezer provides a convenient way to measure compatible SMD inductors and small coils using tweezer-style probes.
For electronics technicians, industrial maintenance engineers and laboratories in Malaysia, understanding how to measure inductance correctly can help improve component-level troubleshooting.
What Is an Inductor?
An inductor is a passive electronic component that stores energy in a magnetic field when electrical current flows through it.
Inductors are commonly found in:
DC-DC converters
Switching power supplies
EMI filtering circuits
Industrial control boards
Communication equipment
Electronic sensor circuits
Power management systems
Inductance is measured in henries (H).
Common units include:
1H = 1,000mH
1mH = 1,000µH
1µH = 1,000nH
For many SMD power electronics applications, inductance values are expressed in microhenries (µH).
Why Use FNIRSI LCR-ST1 for Inductor Testing?
The FNIRSI LCR-ST1 is designed for measuring passive electronic components, including resistors, capacitors and inductors.
Its tweezer-style probes allow technicians to contact small SMD component terminals conveniently.
Key advantages include:
Direct contact with compatible SMD inductors
Inductance measurement
Selectable test frequencies
Resistance and capacitance measurement
Additional impedance-related parameters
Compact handheld design
The instrument can be useful for technicians who frequently inspect small passive components during PCB repair.
FNIRSI LCR-ST1 Key Specifications
FeatureSpecificationModelFNIRSI LCR-ST1Instrument TypeLCR Bridge TweezerInductance Range1µH to 10HResistance Range10mΩ to 10MΩCapacitance Range1pF to 22mFTest Frequencies100Hz / 1kHz / 10kHzTest Signal Levels0.3V / 0.6VParametersR, C, L, ESR, D, Q, Z, XProbe DesignReplaceable tweezer tips
Important: The measurement range does not guarantee the same accuracy for every inductance value. Consult the manufacturer's specifications for accuracy and measurement limitations.
How to Measure an SMD Inductor Using FNIRSI LCR-ST1
Step 1: Disconnect the Power Supply
Switch off the electronic equipment and disconnect all power sources.
Verify that the circuit is de-energized and safely discharge capacitors before testing.
Never connect the FNIRSI LCR-ST1 to an energized circuit.
Step 2: Identify the Inductor
Locate the inductor on the PCB.
Check its component marking, schematic or datasheet to identify the nominal inductance.
Some SMD inductors use numerical markings, while others have no markings.
Step 3: Select Inductance Measurement
Turn on the FNIRSI LCR-ST1 and select the appropriate inductance measurement function.
Follow the manufacturer's instructions for measurement setup and probe correction where applicable.
Step 4: Choose the Test Frequency
The instrument supports:
100Hz
1kHz
10kHz
Select the frequency specified in the component datasheet whenever possible.
Different inductors may produce different readings at different frequencies because of magnetic core properties and parasitic effects.
Step 5: Contact the Inductor Terminals
Place the tweezer tips against both terminals of the inductor.
Maintain stable contact and avoid touching nearby components.
Step 6: Compare the Measurement
Compare the measured inductance with the nominal value and tolerance.
For accurate confirmation, isolate the component when surrounding circuitry could affect the reading.
Example SMD Inductor Measurements
Nominal InductanceExample ReadingPossible Assessment10µH9.8µHClose to nominal22µH21.6µHClose to nominal47µH46.2µHClose to nominal100µH98µHClose to nominal1mH0.99mHClose to nominal
These are illustrative values, not actual FNIRSI LCR-ST1 test results.
Always consider the manufacturer's tolerance, test frequency and measurement conditions.
Understanding Inductor Markings
Some SMD inductors use three-digit numerical markings.
For certain common coding systems, the first two digits represent significant figures and the third digit indicates a multiplier in microhenries.
MarkingExample Inductance10010µH22022µH47047µH101100µH1021,000µH
Important: Inductor marking systems are not universal. Always verify the code against the component manufacturer's documentation.
Why Does Inductance Change with Test Frequency?
An ideal inductor has a fixed inductance value.
However, real inductors contain:
Winding resistance
Magnetic core losses
Parasitic capacitance
Frequency-dependent magnetic characteristics
These properties can influence the measured inductance.
For an ideal inductor, inductive reactance is calculated as:
XL = 2 × π × f × L
Where:
XL = Inductive reactance in ohms
f = Frequency in hertz
L = Inductance in henries
For an ideal 10µH inductor:
FrequencyCalculated Reactance100Hz0.0063Ω1kHz0.0628Ω10kHz0.6283Ω
These are theoretical calculations, not actual instrument readings.
At low reactance values, contact resistance and instrument limitations can become significant.
Common Inductor Testing Problems
Problem 1: Inductance Reading Is Unstable
Possible causes:
Poor electrical contact
Dirty tweezer tips
Movement during testing
Electrical interference
Recommended action: Clean the contact points, stabilize the probes and repeat the measurement.
Problem 2: Inductance Reading Is Lower Than Expected
Possible causes:
Parallel circuit paths
Incorrect test frequency
Component characteristics
Possible internal winding damage
Recommended action: Isolate the component and compare it with the datasheet or a known-good reference.
Problem 3: Inductor Shows Very Low Resistance
Many power inductors naturally have low DC winding resistance.
A low resistance reading does not automatically mean an inductor is short-circuited.
Compare the reading with the component's specified DC resistance.
Problem 4: Inductance Appears Normal but the Circuit Still Fails
An inductor may have faults that are not revealed by a basic inductance measurement.
Examples include:
Shorted turns
Insulation breakdown
Core saturation under load
Temperature-related failures
Additional testing may be required to confirm the component's condition.
FNIRSI LCR-ST1 for DC-DC Converter Repair
DC-DC converters are widely used in industrial electronic equipment, computer motherboards and power management circuits.
They commonly contain inductors used for energy storage during switching operation.
The FNIRSI LCR-ST1 can help technicians check the inductance of suitable components after the circuit has been safely de-energized.
However, an LCR measurement does not reproduce the high-current operating conditions of a DC-DC converter.
For complete troubleshooting, technicians may also require:
Digital multimeter
Oscilloscope
Suitable current measurement equipment
Circuit schematic
Component datasheet
The FNIRSI LCR-ST1 complements these instruments rather than replacing them.
FNIRSI LCR-ST1 vs Digital Multimeter for Inductor Testing
FunctionFNIRSI LCR-ST1Digital MultimeterInductance MeasurementYesModel dependentResistance MeasurementYesYesSMD Tweezer ProbesYesUsually separate probesTest Frequency SelectionYesUsually unavailableVoltage MeasurementNoYesCurrent MeasurementNoYesMain ApplicationPassive component testingGeneral electrical testing
For technicians who regularly measure inductors and small passive components, the FNIRSI LCR-ST1 provides additional measurement capabilities beyond a conventional multimeter.
Applications in Malaysia
Electronics Repair Workshops
Testing SMD inductors during laptop motherboard, power supply and PCB repair.
Industrial Maintenance
Evaluating passive components on automation control boards and industrial electronic modules.
Electronics Manufacturing
Supporting basic inductor identification and component inspection.
Research and Development
Comparing inductor characteristics during circuit prototyping.
Technical Colleges and Universities
Teaching inductance, impedance and frequency-dependent electrical behaviour.
Frequently Asked Questions
Can FNIRSI LCR-ST1 Measure SMD Inductors?
Yes. The instrument supports inductance measurement and uses tweezer-style probes suitable for compatible small components.
Can FNIRSI LCR-ST1 Detect a Shorted Inductor?
It may help identify abnormal electrical characteristics, but shorted turns and other internal faults may require additional testing.
What Frequency Should I Use for Inductor Testing?
Use the frequency specified in the component datasheet whenever possible.
Can FNIRSI LCR-ST1 Measure Inductors on a PCB?
It can measure accessible components on a de-energized PCB, but surrounding circuitry may influence the reading.
Is FNIRSI LCR-ST1 Suitable for Power Supply Repair?
Yes, for suitable passive component measurements. Additional diagnostic instruments are generally required for complete power supply troubleshooting.
FNIRSI LCR-ST1 Supplier Malaysia
MTM Precision Sdn Bhd supplies FNIRSI electronic testing instruments and industrial measurement equipment in Malaysia.
We welcome enquiries from electronics repair workshops, industrial maintenance departments, engineering companies, electronics manufacturers and technical institutions.
Customers from Kuala Lumpur, Selangor, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak can contact MTM Precision for product information, pricing and availability.
Contact MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
WhatsApp: +6016-660 7346
Tel: 03-8080 7172
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for FNIRSI LCR-ST1 pricing, availability and electronic component testing solutions in Malaysia.
09 Oct 2026