FNIRSI LCR-ST1 Inductor Testing Guide Malaysia: How to Measure SMD Coils and Inductance

FNIRSI LCR-ST1 Inductor Testing Guide Malaysia: How to Measure SMD Coils and Inductance

 

Inductor testing is an important part of PCB troubleshooting, switching power supply repair and industrial electronic maintenance.

 

Inductors are widely used in electronic circuits for energy storage, filtering and electromagnetic interference reduction.

 

The FNIRSI LCR-ST1 LCR Bridge Tweezer provides a convenient way to measure compatible SMD inductors and small coils using tweezer-style probes.

 

For electronics technicians, industrial maintenance engineers and laboratories in Malaysia, understanding how to measure inductance correctly can help improve component-level troubleshooting.

 

What Is an Inductor?

 

An inductor is a passive electronic component that stores energy in a magnetic field when electrical current flows through it.

 

Inductors are commonly found in:

 

DC-DC converters

 

Switching power supplies

 

EMI filtering circuits

 

Industrial control boards

 

Communication equipment

 

Electronic sensor circuits

 

Power management systems

 

Inductance is measured in henries (H).

 

Common units include:

 

1H = 1,000mH

 

1mH = 1,000µH

 

1µH = 1,000nH

 

For many SMD power electronics applications, inductance values are expressed in microhenries (µH).

 

Why Use FNIRSI LCR-ST1 for Inductor Testing?

 

The FNIRSI LCR-ST1 is designed for measuring passive electronic components, including resistors, capacitors and inductors.

 

Its tweezer-style probes allow technicians to contact small SMD component terminals conveniently.

 

Key advantages include:

 

Direct contact with compatible SMD inductors

 

Inductance measurement

 

Selectable test frequencies

 

Resistance and capacitance measurement

 

Additional impedance-related parameters

 

Compact handheld design

 

The instrument can be useful for technicians who frequently inspect small passive components during PCB repair.

 

FNIRSI LCR-ST1 Key Specifications

 

FeatureSpecificationModelFNIRSI LCR-ST1Instrument TypeLCR Bridge TweezerInductance Range1µH to 10HResistance Range10mΩ to 10MΩCapacitance Range1pF to 22mFTest Frequencies100Hz / 1kHz / 10kHzTest Signal Levels0.3V / 0.6VParametersR, C, L, ESR, D, Q, Z, XProbe DesignReplaceable tweezer tips

 

Important: The measurement range does not guarantee the same accuracy for every inductance value. Consult the manufacturer's specifications for accuracy and measurement limitations.

 

How to Measure an SMD Inductor Using FNIRSI LCR-ST1

 

Step 1: Disconnect the Power Supply

 

Switch off the electronic equipment and disconnect all power sources.

 

Verify that the circuit is de-energized and safely discharge capacitors before testing.

 

Never connect the FNIRSI LCR-ST1 to an energized circuit.

 

Step 2: Identify the Inductor

 

Locate the inductor on the PCB.

 

Check its component marking, schematic or datasheet to identify the nominal inductance.

 

Some SMD inductors use numerical markings, while others have no markings.

 

Step 3: Select Inductance Measurement

 

Turn on the FNIRSI LCR-ST1 and select the appropriate inductance measurement function.

 

Follow the manufacturer's instructions for measurement setup and probe correction where applicable.

 

Step 4: Choose the Test Frequency

 

The instrument supports:

 

100Hz

 

1kHz

 

10kHz

 

Select the frequency specified in the component datasheet whenever possible.

 

Different inductors may produce different readings at different frequencies because of magnetic core properties and parasitic effects.

 

Step 5: Contact the Inductor Terminals

 

Place the tweezer tips against both terminals of the inductor.

 

Maintain stable contact and avoid touching nearby components.

 

Step 6: Compare the Measurement

 

Compare the measured inductance with the nominal value and tolerance.

 

For accurate confirmation, isolate the component when surrounding circuitry could affect the reading.

 

Example SMD Inductor Measurements

 

Nominal InductanceExample ReadingPossible Assessment10µH9.8µHClose to nominal22µH21.6µHClose to nominal47µH46.2µHClose to nominal100µH98µHClose to nominal1mH0.99mHClose to nominal

 

These are illustrative values, not actual FNIRSI LCR-ST1 test results.

 

Always consider the manufacturer's tolerance, test frequency and measurement conditions.

 

Understanding Inductor Markings

 

Some SMD inductors use three-digit numerical markings.

 

For certain common coding systems, the first two digits represent significant figures and the third digit indicates a multiplier in microhenries.

 

MarkingExample Inductance10010µH22022µH47047µH101100µH1021,000µH

 

Important: Inductor marking systems are not universal. Always verify the code against the component manufacturer's documentation.

 

Why Does Inductance Change with Test Frequency?

 

An ideal inductor has a fixed inductance value.

 

However, real inductors contain:

 

Winding resistance

 

Magnetic core losses

 

Parasitic capacitance

 

Frequency-dependent magnetic characteristics

 

These properties can influence the measured inductance.

 

For an ideal inductor, inductive reactance is calculated as:

 

XL = 2 × π × f × L

 

Where:

 

XL = Inductive reactance in ohms

 

f = Frequency in hertz

 

L = Inductance in henries

 

For an ideal 10µH inductor:

 

FrequencyCalculated Reactance100Hz0.0063Ω1kHz0.0628Ω10kHz0.6283Ω

 

These are theoretical calculations, not actual instrument readings.

 

At low reactance values, contact resistance and instrument limitations can become significant.

 

Common Inductor Testing Problems

 

Problem 1: Inductance Reading Is Unstable

 

Possible causes:

 

Poor electrical contact

 

Dirty tweezer tips

 

Movement during testing

 

Electrical interference

 

Recommended action: Clean the contact points, stabilize the probes and repeat the measurement.

 

Problem 2: Inductance Reading Is Lower Than Expected

 

Possible causes:

 

Parallel circuit paths

 

Incorrect test frequency

 

Component characteristics

 

Possible internal winding damage

 

Recommended action: Isolate the component and compare it with the datasheet or a known-good reference.

 

Problem 3: Inductor Shows Very Low Resistance

 

Many power inductors naturally have low DC winding resistance.

 

A low resistance reading does not automatically mean an inductor is short-circuited.

 

Compare the reading with the component's specified DC resistance.

 

Problem 4: Inductance Appears Normal but the Circuit Still Fails

 

An inductor may have faults that are not revealed by a basic inductance measurement.

 

Examples include:

 

Shorted turns

 

Insulation breakdown

 

Core saturation under load

 

Temperature-related failures

 

Additional testing may be required to confirm the component's condition.

 

FNIRSI LCR-ST1 for DC-DC Converter Repair

 

DC-DC converters are widely used in industrial electronic equipment, computer motherboards and power management circuits.

 

They commonly contain inductors used for energy storage during switching operation.

 

The FNIRSI LCR-ST1 can help technicians check the inductance of suitable components after the circuit has been safely de-energized.

 

However, an LCR measurement does not reproduce the high-current operating conditions of a DC-DC converter.

 

For complete troubleshooting, technicians may also require:

 

Digital multimeter

 

Oscilloscope

 

Suitable current measurement equipment

 

Circuit schematic

 

Component datasheet

 

The FNIRSI LCR-ST1 complements these instruments rather than replacing them.

 

FNIRSI LCR-ST1 vs Digital Multimeter for Inductor Testing

 

FunctionFNIRSI LCR-ST1Digital MultimeterInductance MeasurementYesModel dependentResistance MeasurementYesYesSMD Tweezer ProbesYesUsually separate probesTest Frequency SelectionYesUsually unavailableVoltage MeasurementNoYesCurrent MeasurementNoYesMain ApplicationPassive component testingGeneral electrical testing

 

For technicians who regularly measure inductors and small passive components, the FNIRSI LCR-ST1 provides additional measurement capabilities beyond a conventional multimeter.

 

Applications in Malaysia

 

Electronics Repair Workshops

 

Testing SMD inductors during laptop motherboard, power supply and PCB repair.

 

Industrial Maintenance

 

Evaluating passive components on automation control boards and industrial electronic modules.

 

Electronics Manufacturing

 

Supporting basic inductor identification and component inspection.

 

Research and Development

 

Comparing inductor characteristics during circuit prototyping.

 

Technical Colleges and Universities

 

Teaching inductance, impedance and frequency-dependent electrical behaviour.

 

Frequently Asked Questions

 

Can FNIRSI LCR-ST1 Measure SMD Inductors?

 

Yes. The instrument supports inductance measurement and uses tweezer-style probes suitable for compatible small components.

 

Can FNIRSI LCR-ST1 Detect a Shorted Inductor?

 

It may help identify abnormal electrical characteristics, but shorted turns and other internal faults may require additional testing.

 

What Frequency Should I Use for Inductor Testing?

 

Use the frequency specified in the component datasheet whenever possible.

 

Can FNIRSI LCR-ST1 Measure Inductors on a PCB?

 

It can measure accessible components on a de-energized PCB, but surrounding circuitry may influence the reading.

 

Is FNIRSI LCR-ST1 Suitable for Power Supply Repair?

 

Yes, for suitable passive component measurements. Additional diagnostic instruments are generally required for complete power supply troubleshooting.

 

FNIRSI LCR-ST1 Supplier Malaysia

 

MTM Precision Sdn Bhd supplies FNIRSI electronic testing instruments and industrial measurement equipment in Malaysia.

 

We welcome enquiries from electronics repair workshops, industrial maintenance departments, engineering companies, electronics manufacturers and technical institutions.

 

Customers from Kuala Lumpur, Selangor, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak can contact MTM Precision for product information, pricing and availability.

 

Contact MTM Precision Sdn Bhd

 

Showroom & Service Centre

 

No. 29-1 & 2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

WhatsApp: +6016-660 7346

 

Tel: 03-8080 7172

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my

 

Contact MTM Precision today for FNIRSI LCR-ST1 pricing, availability and electronic component testing solutions in Malaysia.


 

09 Oct 2026