FNIRSI LCR-ST1 for Electronics Students Malaysia: Learn Resistance, Capacitance and Inductance Testing
FNIRSI LCR-ST1 for Electronics Students Malaysia: Learn Resistance, Capacitance and Inductance Testing
Learning how to measure resistance, capacitance and inductance is an essential part of electronics engineering education.
Students studying electrical engineering, electronics technology, mechatronics and industrial automation regularly work with resistors, capacitors and inductors during laboratory experiments.
The FNIRSI LCR-ST1 LCR Bridge Tweezer is a compact electronic testing instrument designed to measure passive components using integrated tweezer-style probes.
For universities, polytechnics, technical colleges and electronics students in Malaysia, the FNIRSI LCR-ST1 can provide a convenient way to explore component characteristics and develop practical measurement skills.
Why Do Electronics Students Need an LCR Meter?
An LCR meter measures three important electrical properties:
L - Inductance
C - Capacitance
R - Resistance
These properties are fundamental to understanding electronic circuits.
Students encounter passive components in many applications, including:
DC and AC circuits
Power supply design
Signal filtering
Electronic circuit prototyping
PCB assembly
Industrial control systems
Communication electronics
Embedded system development
Although a digital multimeter can measure resistance and may support capacitance, many models do not measure inductance or provide selectable AC test frequencies.
An LCR meter allows students to explore additional electrical characteristics beyond basic multimeter measurements.
What Is the FNIRSI LCR-ST1?
The FNIRSI LCR-ST1 is a handheld LCR bridge tweezer intended for passive electronic component measurement.
Its tweezer-style probes are particularly convenient for small surface-mount devices (SMD).
FNIRSI LCR-ST1 Key Specifications
FeatureSpecificationModelFNIRSI LCR-ST1Instrument TypeLCR Bridge TweezerResistance Range10mΩ to 10MΩCapacitance Range1pF to 22mFInductance Range1µH to 10HTest Frequencies100Hz / 1kHz / 10kHzTest Signal Levels0.3V / 0.6VMeasurement ParametersR, C, L, ESR, D, Q, Z, XProbe DesignReplaceable tweezer tipsMain ApplicationPassive component testing
Measurement accuracy and suitability depend on component characteristics, instrument specifications and testing conditions.
Experiment 1: Measuring Resistance
Resistance is the opposition to electric current.
It is measured in ohms (Ω).
Students can use the FNIRSI LCR-ST1 to measure suitable resistors and compare the results with their nominal values.
Example Laboratory Activity
Prepare several resistors:
100Ω
1kΩ
4.7kΩ
10kΩ
100kΩ
Measure each resistor and record the reading.
Nominal ResistanceExample Measurement100Ω99.8Ω1kΩ998Ω4.7kΩ4.69kΩ10kΩ10.1kΩ100kΩ99.5kΩ
These are hypothetical examples, not actual FNIRSI LCR-ST1 measurement results.
Learning Objectives
Students can learn:
How resistance is measured
The meaning of resistor tolerance
Why measured values differ from nominal values
How probe contact affects readings
How to calculate percentage error
Percentage Error Formula
Percentage Error = |Measured Value - Reference Value| / Reference Value × 100%
For example, if a 1kΩ reference resistor is measured as 990Ω:
Percentage Error = 1%
For a proper accuracy experiment, students should use a suitable reference value and account for the uncertainty of the reference and measuring instrument.
Experiment 2: Measuring Capacitance
Capacitance describes a component's ability to store electric charge.
It is measured in farads (F).
Common units include:
1µF = 1,000nF
1nF = 1,000pF
The FNIRSI LCR-ST1 can measure suitable capacitors within its supported range.
Example Laboratory Activity
Prepare capacitors with different nominal values.
CapacitorNominal CapacitanceC1100pFC210nFC3100nFC41µFC510µF
Measure each capacitor and compare the results with its specification.
Learning Objectives
Students can investigate:
Capacitance measurement
Capacitor tolerance
Frequency-dependent behaviour
Differences between capacitor types
Measurement stability
Important: Some ceramic capacitors exhibit changes in capacitance with temperature, applied DC bias and test conditions.
Measurements should be compared under appropriate conditions.
Experiment 3: Measuring Inductance
Inductance is the property of a conductor or coil that opposes changes in current.
It is measured in henries (H).
Inductors are commonly used in:
DC-DC converters
Power supplies
EMI filters
Signal processing circuits
Electronic oscillators
Example Laboratory Activity
Prepare inductors with nominal values such as:
10µH
22µH
47µH
100µH
1mH
Use the FNIRSI LCR-ST1 to measure the inductance of each component.
Nominal InductanceExample Measurement10µH9.8µH22µH21.7µH47µH46.5µH100µH99µH1mH0.98mH
These are illustrative readings.
Learning Objectives
Students can learn:
How inductance is measured
Why inductance changes with frequency
The effect of magnetic core materials
Differences between ideal and real inductors
The importance of component datasheets
Experiment 4: Understanding Test Frequency
The FNIRSI LCR-ST1 supports three test frequencies:
100Hz, 1kHz and 10kHz.
Students can measure the same capacitor or inductor at different frequencies and compare the results.
Suggested Laboratory Procedure
Select a suitable capacitor or inductor.
Measure it at 100Hz.
Repeat the measurement at 1kHz.
Repeat the measurement at 10kHz.
Record the results.
Compare the measured values.
Explain any observed differences.
Example Recording Table
Test FrequencyMeasured ValueObservation100HzRecord resultLow-frequency measurement1kHzRecord resultCompare with 100Hz10kHzRecord resultCompare with 1kHz
The actual results depend on the component and measurement conditions.
This experiment helps students understand that real electronic components may behave differently at different frequencies.
Experiment 5: Understanding Capacitor ESR
ESR stands for Equivalent Series Resistance.
Real capacitors contain resistive losses that can influence circuit performance.
ESR is especially relevant in power supply and filtering applications.
The FNIRSI LCR-ST1 supports ESR measurement at its available test frequencies.
Suggested Learning Activity
Measure the ESR of several compatible capacitors of similar type and rating.
Compare their readings under the same test conditions.
Students should consider:
Capacitor construction
Measurement frequency
Temperature
Component condition
Contact resistance
A higher ESR reading does not automatically mean a capacitor is defective.
Results should be interpreted using appropriate specifications or reference components.
The FNIRSI LCR-ST1 does not support 100kHz ESR testing.
Experiment 6: SMD Component Identification
Modern electronic circuits use small SMD components.
Some SMD resistors have printed codes, while many small capacitors and inductors have no markings.
The FNIRSI LCR-ST1 can help students identify compatible passive components by measurement.
Suggested Activity
Prepare a selection of loose SMD components.
Ask students to:
Identify the component type.
Measure the electrical value.
Record the result.
Compare the measurement with the component specification.
Explain possible sources of measurement error.
This activity supports practical electronics assembly and troubleshooting skills.
FNIRSI LCR-ST1 vs Digital Multimeter for Students
FunctionFNIRSI LCR-ST1Digital MultimeterResistanceYesYesCapacitanceYesModel dependentInductanceYesModel dependentESRYesUsually unavailableSelectable LCR FrequencyYesUsually unavailableSMD Tweezer ProbesIntegratedUsually separateVoltage MeasurementNoYesCurrent MeasurementNoYes
For electronics education, both instruments can serve complementary purposes.
A digital multimeter is essential for general electrical measurements, while an LCR meter allows students to investigate passive component characteristics in greater detail.
Recommended Laboratory Safety Practices
Before using the FNIRSI LCR-ST1:
Disconnect all electrical power sources.
Verify that the circuit is de-energized.
Safely discharge capacitors.
Avoid measuring components connected to live circuits.
Follow the manufacturer's operating instructions.
Use suitable components within the instrument's supported measurement range.
Never connect the FNIRSI LCR-ST1 to an energized circuit.
For introductory laboratory activities, loose passive components are generally preferable to measurements on complex assembled circuits.
Who Can Benefit from FNIRSI LCR-ST1?
University Engineering Students
For learning passive component measurement and circuit behaviour.
Polytechnic Students
For practical electronics laboratory exercises.
Technical College Students
For developing component identification and troubleshooting skills.
Electronics Hobbyists
For evaluating resistors, capacitors and inductors during personal projects.
Engineering Laboratories
For convenient preliminary component measurements and prototyping.
Electronics Training Centres
For demonstrating basic LCR measurement principles.
Frequently Asked Questions
Is FNIRSI LCR-ST1 Suitable for Electronics Students?
Yes. It can help students learn resistance, capacitance, inductance and other passive component measurements.
Can FNIRSI LCR-ST1 Measure SMD Components?
Yes. Its integrated tweezer-style probes are designed for convenient contact with compatible small passive components.
Can Students Use FNIRSI LCR-ST1 to Learn ESR Measurement?
Yes. The instrument supports ESR measurement at its available test frequencies.
Does FNIRSI LCR-ST1 Replace a Digital Multimeter?
No. A digital multimeter remains necessary for voltage, current and general electrical measurements.
Can FNIRSI LCR-ST1 Be Used in University Laboratories?
It may be suitable for educational exercises and preliminary measurements. Laboratories requiring specified accuracy or traceable calibration should verify that the instrument meets their requirements.
What Test Frequencies Does FNIRSI LCR-ST1 Support?
The instrument supports 100Hz, 1kHz and 10kHz.
FNIRSI LCR-ST1 Supplier Malaysia
MTM Precision Sdn Bhd supplies FNIRSI electronic testing instruments and industrial measurement equipment in Malaysia.
We welcome enquiries from:
Universities
Polytechnics
Technical colleges
Electronics training centres
Engineering laboratories
Electronics students
Research and development departments
Customers from Kuala Lumpur, Selangor, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak can contact MTM Precision for product information, pricing and availability.
Contact MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
WhatsApp: +6016-660 7346
Tel: 03-8080 7172
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for FNIRSI LCR-ST1 pricing, availability and electronic component testing solutions in Malaysia.
09 Oct 2026