FNIRSI HRM-10 How to Test 18650 Lithium Battery Internal Resistance Malaysia
FNIRSI HRM-10 How to Test 18650 Lithium Battery Internal Resistance Malaysia
Introduction
The 18650 lithium-ion battery is widely used in rechargeable electronic equipment, battery packs, portable instruments and energy storage applications.
For battery repair technicians and electronics professionals, checking battery voltage alone may not provide enough information about the condition of an individual cell.
A battery can display normal voltage but still experience poor performance under load.
The FNIRSI HRM-10 Battery Internal Resistance Tester allows technicians to measure battery internal resistance and DC voltage using a dedicated handheld instrument.
This guide explains how to test 18650 lithium-ion battery cells, interpret resistance measurements and avoid common testing mistakes.
What Is an 18650 Lithium Battery?
An 18650 lithium-ion battery is a cylindrical rechargeable battery cell with an approximate diameter of 18mm and length of 65mm, although actual dimensions vary with cell design and protection circuitry.
These batteries are commonly used in:
-
Rechargeable battery packs
-
Portable electronic devices
-
Industrial instruments
-
Emergency lighting
-
Battery-powered equipment
-
Electronics repair applications
-
Energy storage assemblies
Many conventional 18650 lithium-ion cells have a nominal voltage of approximately 3.6V or 3.7V.
However, the operating voltage and charging limits depend on the specific battery chemistry.
Why Test 18650 Battery Internal Resistance?
Battery internal resistance influences the voltage drop and heating that occur when a battery supplies current.
Internal resistance may change because of ageing, temperature, state of charge and electrochemical deterioration.
A battery with unusually high internal resistance may perform poorly when supplying current.
For battery pack assembly and maintenance, resistance testing can help technicians compare cells of the same type.
The FNIRSI HRM-10 provides a convenient method for measuring low resistance values in milliohms.
However, internal resistance testing does not directly determine the battery's actual capacity or remaining service life.
FNIRSI HRM-10 Features for 18650 Battery Testing
The FNIRSI HRM-10 includes several functions relevant to lithium battery inspection.
| Feature | Description |
|---|---|
| Battery Voltage | Measures DC voltage |
| Internal Resistance | Measures battery AC internal resistance |
| Measurement Method | Approximately 1kHz AC |
| Connection | Four-Wire Kelvin |
| Resistance Range | Up to 200Ω |
| DC Voltage Range | Up to ±100V DC |
| Battery Sorting | Supports comparison and sorting functions |
| Data Recording | Supports measurement record functions |
Important: Measurement resolution and accuracy depend on the selected range. Refer to the latest FNIRSI specifications and operating manual for detailed limits.
How to Test 18650 Battery Internal Resistance with FNIRSI HRM-10
Step 1 - Inspect the Battery
Before testing, inspect the 18650 battery cell for visible damage.
Check for:
-
Swelling or deformation
-
Damaged insulation
-
Corrosion
-
Leakage
-
Overheating marks
-
Damaged terminals
Do not test a battery showing signs of serious damage or unsafe condition using routine procedures.
Such batteries should be isolated and handled according to appropriate battery safety requirements.
Step 2 - Confirm Battery Specifications
Identify the battery model, chemistry and nominal voltage.
For meaningful comparison, technicians should test cells with similar specifications.
Avoid comparing resistance values from unrelated battery types without manufacturer reference data.
Step 3 - Prepare the FNIRSI HRM-10
Connect the supplied Kelvin measurement leads according to the manufacturer's instructions.
Check that the probes and cables are in suitable condition.
If the instrument requires a zero adjustment or calibration procedure, follow the official operating manual.
Step 4 - Connect the Battery Probes
Place the measurement probes securely against the positive and negative battery terminals.
Ensure stable electrical contact.
Avoid accidentally short-circuiting the battery terminals with the probe tips.
Correct Kelvin probe contact is especially important when measuring very low resistance values.
Step 5 - Measure Battery Voltage
Observe the DC voltage displayed by the instrument.
For example, a conventional 3.6V or 3.7V nominal lithium-ion cell may display approximately 3.8V during inspection.
This provides information about the battery's terminal voltage but does not establish its complete health condition.
Step 6 - Measure Internal Resistance
Observe the internal resistance reading.
For example, the instrument may display a resistance value in milliohms.
Record the measurement together with the battery voltage.
Step 7 - Compare Similar Battery Cells
Repeat the procedure on other cells of the same model.
Try to maintain similar:
-
Battery temperature
-
State of charge
-
Probe positioning
-
Measurement conditions
-
Testing equipment settings
Consistent conditions improve the usefulness of resistance comparisons.
Example of 18650 Battery Resistance Testing
The following table shows an illustrative comparison of four 18650 battery cells.
| Battery Cell | Voltage | Internal Resistance |
|---|---|---|
| Cell A | 3.82V | 24mΩ |
| Cell B | 3.81V | 26mΩ |
| Cell C | 3.83V | 25mΩ |
| Cell D | 3.82V | 85mΩ |
These values are examples for explanation only and are not universal battery acceptance criteria.
Cells A, B and C have relatively similar resistance readings.
Cell D has a substantially higher resistance reading despite showing a similar voltage.
This may justify further inspection of Cell D.
Technicians should first repeat the measurement and check probe contact, temperature and cell identification.
If the difference remains, additional capacity or load testing may be appropriate.
A high resistance reading alone does not automatically establish that a battery is defective.
What Is a Good Internal Resistance for an 18650 Battery?
There is no single resistance value that applies to every 18650 lithium-ion battery.
Internal resistance depends on:
-
Battery manufacturer
-
Cell chemistry
-
Rated capacity
-
High-drain or energy-cell design
-
Battery temperature
-
State of charge
-
Age and usage history
-
Measurement method
Some high-current cells are designed with relatively low internal resistance, while other cell types may have higher resistance values under normal conditions.
For accurate assessment, technicians should compare results with the battery manufacturer's specifications or a suitable baseline measurement.
Avoid using a universal milliohm threshold to classify every 18650 battery as good or bad.
Why Four-Wire Kelvin Testing Is Important
Battery internal resistance is often very low.
A conventional two-wire resistance measurement includes resistance from the test leads and connections.
This can create significant measurement errors when testing milliohm-level resistance.
The FNIRSI HRM-10 uses four-wire Kelvin measurement to help reduce the influence of test lead resistance.
This is particularly useful for comparing lithium-ion cells with low internal resistance.
However, the Kelvin method does not eliminate every measurement error.
Technicians should still ensure clean terminals, stable contact and consistent testing conditions.
Can FNIRSI HRM-10 Measure 18650 Battery Capacity?
No.
The FNIRSI HRM-10 measures internal resistance and DC voltage, but it does not directly measure the full discharge capacity of a battery in mAh.
Battery capacity testing generally requires controlled charging or discharging under defined conditions.
For example, a battery rated at 2500mAh should be evaluated using a suitable battery capacity tester and the manufacturer's recommended test procedure.
Internal resistance testing can complement capacity testing but cannot replace it.
FNIRSI HRM-10 vs Battery Capacity Tester
| Function | FNIRSI HRM-10 | Battery Capacity Tester |
|---|---|---|
| DC Voltage Measurement | Yes | Usually |
| AC Internal Resistance Measurement | Yes | Depends on Model |
| Capacity Measurement in mAh | No | Yes |
| Cell Resistance Comparison | Yes | Depends on Model |
| Controlled Discharge Test | No | Yes |
| Battery Health Evaluation | Supplementary | Supplementary |
For a more complete battery assessment, technicians may use both instruments.
Applications in Battery Repair Workshops
The FNIRSI HRM-10 is useful for electronics and battery repair workshops handling rechargeable battery cells.
Typical applications include:
Battery Cell Screening
Compare individual cells before further testing.
Battery Pack Repair Assessment
Identify cells with unusual resistance readings for additional investigation.
Battery Sorting
Group compatible cells based on measured characteristics, together with other required selection criteria.
Battery Maintenance Records
Record resistance and voltage measurements for comparison over time.
Electronics Troubleshooting
Investigate batteries that appear charged but perform poorly during equipment operation.
Common Mistakes When Testing 18650 Batteries
1. Testing Batteries at Different Temperatures
Internal resistance changes with temperature.
Recommendation: Compare cells under similar temperature conditions.
2. Using Dirty Battery Terminals
Corrosion or contamination can affect measurement contact.
Recommendation: Ensure terminals are clean and suitable for testing.
3. Comparing Different Cell Models
Different 18650 models may have different normal resistance characteristics.
Recommendation: Compare cells of the same model whenever possible.
4. Assuming Voltage Indicates Capacity
A battery with normal voltage may still have reduced capacity.
Recommendation: Perform suitable capacity testing when required.
5. Ignoring Battery Safety
Lithium-ion batteries can present fire and thermal hazards if damaged, short-circuited or mishandled.
Recommendation: Follow appropriate battery safety procedures and manufacturer instructions.
Who Should Use the FNIRSI HRM-10 in Malaysia?
The FNIRSI HRM-10 Battery Internal Resistance Tester is relevant to several technical industries.
Electronics Repair Technicians
For inspection of rechargeable batteries used in electronic devices.
Battery Pack Assembly Workshops
For measuring individual cells before further sorting and assembly.
Industrial Maintenance Teams
For inspecting compatible battery-powered equipment.
Engineering Laboratories
For educational and technical battery measurement applications.
Battery Repair Businesses
For troubleshooting batteries with inconsistent electrical performance.
Frequently Asked Questions
Q1. Can FNIRSI HRM-10 test 18650 lithium-ion batteries?
Yes. The FNIRSI HRM-10 can measure internal resistance and voltage on compatible 18650 lithium-ion cells.
Q2. What is the normal internal resistance of an 18650 battery?
There is no universal normal value. It depends on the cell model, chemistry, temperature, state of charge and measurement method.
Q3. Can internal resistance identify a bad battery?
An unusually high reading can indicate a potential problem, but further testing may be necessary before determining whether the battery is defective.
Q4. Can the FNIRSI HRM-10 measure battery capacity in mAh?
No. A dedicated capacity testing method is required to measure actual battery capacity.
Q5. Why do two batteries with the same voltage have different resistance?
The batteries may differ in age, condition, chemistry, temperature or manufacturing characteristics.
Q6. Is the FNIRSI HRM-10 suitable for battery pack assembly?
It can assist with cell inspection and resistance comparison. Safe battery pack assembly also requires capacity matching, suitable protection circuitry, appropriate cell selection and established safety procedures.
Conclusion
Testing 18650 lithium battery internal resistance provides additional information beyond conventional voltage measurement.
The FNIRSI HRM-10 Battery Internal Resistance Tester helps technicians measure battery voltage and internal resistance using a four-wire Kelvin measurement arrangement.
It is useful for lithium battery inspection, cell comparison, electronics repair and selected battery maintenance applications.
For battery repair workshops and technical professionals in Malaysia, the HRM-10 offers a practical way to support more systematic battery testing.
Where to Buy FNIRSI HRM-10 in Malaysia?
MTM Precision Sdn Bhd supplies electrical testing instruments, industrial measuring equipment and battery inspection tools in Malaysia.
Customers searching for FNIRSI HRM-10 18650 Battery Internal Resistance Tester Malaysia can contact MTM Precision for product information, quotations and availability.
We support customers across Kuala Lumpur, Selangor, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak.
Contact MTM Precision Sdn Bhd
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for FNIRSI HRM-10 product information, quotations and availability in Malaysia.
10 Oct 2026