FNIRSI FNAC-28 USB Charger Testing for Electronics Repair Shops Malaysia
FNIRSI FNAC-28 USB Charger Testing for Electronics Repair Shops Malaysia
Introduction
Electronics repair shops regularly receive devices with charging-related complaints.
Customers may report that their smartphones charge slowly, USB chargers stop working, charging cables disconnect intermittently or power banks fail to supply sufficient power.
These symptoms do not always indicate a defective device.
The actual cause may involve USB charger output, charging cable resistance, connector condition, charging protocol compatibility or the device's internal charging controls.
For repair workshops, a consistent diagnostic procedure can help technicians identify possible causes before replacing components.
The FNIRSI FNAC-28 USB Tester is a compact instrument for measuring compatible USB voltage, current and power.
It also provides selected charging protocol functions and supported cable resistance testing.
This guide explains how electronics repair shops in Malaysia can incorporate the FNIRSI FNAC-28 USB Charger Tester into routine troubleshooting, customer service and repair verification.
1. Why Electronics Repair Shops Need USB Testing Equipment
A customer complaint such as "my phone charges slowly" does not identify the defective component.
Several parts of the charging system may contribute to the problem.
These include:
USB Power Adapter
USB Charging Cable
Charging Port
Battery
Charging Controller
Device Firmware
Fast-Charging Protocol Compatibility
Without electrical measurements, technicians may spend unnecessary time replacing accessories or investigating internal circuits.
A USB tester provides additional information about the power being transferred through a compatible charging connection.
However, USB electrical measurements should support diagnosis rather than replace a complete repair assessment.
2. FNIRSI FNAC-28 Specifications for Workshop Use
ParameterDescriptionModelFNIRSI FNAC-28Instrument CategoryUSB Digital TesterVoltage Measurement Range4V to 24VCurrent Measurement Range0A to 6.5AMaximum Rated Power156WUSB InterfacesUSB-A and USB Type-CMain MeasurementsVoltage, Current and PowerAdditional FunctionsCharging Monitoring and Supported Cable Resistance TestingProtocol FunctionsSelected Fast-Charging Protocol Detection and TriggeringMain ApplicationsCharger, Cable and Power Bank Testing
The FNIRSI FNAC-28 is suitable for preliminary measurements in compatible USB charging systems.
Important: It does not support USB PD active triggering or USB PD packet capture.
For detailed USB Power Delivery analysis, a dedicated USB PD instrument may be necessary.
3. A Five-Stage USB Charging Diagnostic Workflow
A repair workshop can organise USB charging investigations into five stages.
StageWorkshop ActivityObjective1Customer Complaint RecordingUnderstand the Reported Problem2Visual InspectionIdentify Obvious Damage3Electrical MeasurementRecord USB Voltage, Current and Power4Fault IsolationCompare Chargers, Cables and Devices5Repair VerificationConfirm Performance After Corrective Action
This structured process can help technicians document their findings and explain results to customers.
4. Stage 1 - Record the Customer Complaint
Before testing, ask the customer to describe the charging problem.
Useful questions include:
Does the device charge slowly or not at all?
Does the charging connection disconnect intermittently?
Does the problem occur with different chargers?
Does the device become unusually hot?
Does fast charging activate?
Has the charger or cable recently been replaced?
Does the problem occur only at certain battery levels?
Example Workshop Intake Record
FieldExample EntryDeviceCustomer SmartphoneComplaintSlow ChargingChargerCustomer-Supplied USB ChargerCableCustomer-Supplied USB CableReported SymptomCharging Takes Longer Than UsualVisible DamageNone ObservedTest RequiredUSB Input Measurement
Recording the original complaint helps technicians compare the customer's experience with actual test observations.
5. Stage 2 - Inspect the Charger and Cable
Visual inspection should be completed before electrical testing.
Check the charger for:
Cracked Housing
Damaged Pins
Unusual Discolouration
Signs of Overheating
Loose USB Ports
Check the cable for:
Damaged Insulation
Bent Connectors
Loose Contacts
Exposed Conductors
Corrosion
Do not continue testing equipment showing serious damage or unsafe conditions.
A visibly damaged charger or cable should not be energised merely to obtain a measurement.
6. Stage 3 - Measure USB Voltage, Current and Power
The FNIRSI FNAC-28 can help technicians observe electrical parameters during compatible USB charging.
Step 1 - Select a Suitable Test Arrangement
Use the appropriate USB connection supported by the tester.
Confirm that the charger and load are within the instrument's specified operating limits.
Step 2 - Connect the FNIRSI FNAC-28
Install the tester according to the manufacturer's operating instructions.
Step 3 - Connect a Compatible Device or Load
A controlled electronic load is preferable when evaluating charger output stability.
A smartphone may also be used for observing real charging behaviour, but its current demand can change over time.
Step 4 - Record the Measurements
Record:
Voltage (V)
Current (A)
Power (W)
Step 5 - Observe Charging Behaviour
Check whether the readings remain stable or change during operation.
Example Measurements
Test ConditionVoltageCurrentCalculated PowerBasic Charging5.0V1.0A5.0WHigher-Current Charging5.0V2.0A10.0WCompatible Fast Charging9.0V2.0A18.0W
These are illustrative calculations, not actual test results.
7. Stage 4 - Isolate the Fault
Fault isolation involves changing one test variable at a time.
For example, if a smartphone charges slowly, a technician can compare the following arrangements:
Test A: Customer charger and customer cable.
Test B: Customer charger and known-good cable.
Test C: Known-good charger and known-good cable.
Test D: Suitable controlled load with the suspected charger.
This approach helps determine whether the problem is more likely related to the charger, cable or connected device.
Example Comparison
Test ArrangementMeasured PowerCustomer Charger and Cable4.0WCustomer Charger with Known-Good Cable8.0WKnown-Good Charger and Cable9.0W
These are hypothetical measurements.
The improvement after replacing the cable may indicate that the original cable contributes to the charging problem.
However, smartphone battery level, temperature and charging protocol conditions must also be considered.
Do not diagnose a faulty cable or charger from a single uncontrolled measurement.
8. Stage 5 - Verify the Repair
After replacing a defective accessory or completing a suitable repair, technicians should repeat the relevant test.
For example:
If the original problem involved intermittent charging, check whether the connection now remains stable.
If the complaint involved slow charging, compare charging measurements under conditions similar to the initial test.
Example Repair Verification Record
ParameterBefore Corrective ActionAfter Corrective ActionCharging ConnectionIntermittentStable During TestMeasured Voltage4.8V5.0VMeasured Current0.6A1.8ACalculated Power2.88W9.0WAction TakenSuspected Cable ProblemCable Replaced
These are illustrative values.
The technician should also confirm that the equipment operates safely and meets the customer's intended use.
9. Common Repair Shop Case Study - Slow Smartphone Charging
Customer Complaint
A customer reports that a smartphone charges much more slowly than before.
Initial Inspection
The charging cable appears worn near the connector.
Electrical Test
The technician measures charging power using the customer's existing charger and cable.
Comparison Test
The technician replaces the cable with a compatible known-good cable.
Observation
Charging power increases under similar conditions.
Recommended Action
Replace the damaged cable and repeat the charging test.
Key Lesson
External charging accessories should be checked before replacing internal smartphone components.
This case is illustrative and does not represent a documented customer repair.
10. Common Repair Shop Case Study - Charger Output Drops Under Load
Customer Complaint
A USB-powered device repeatedly disconnects during operation.
Initial Test
The charger provides voltage when lightly loaded.
Controlled Load Test
A suitable electronic load is connected within the charger's rated limits.
Observation
The measured output voltage decreases significantly as current demand increases.
Possible Causes
Charger output limitation
Internal charger fault
Cable resistance
Poor connector contact
Protection circuit operation
Recommended Action
Compare the charger with a known-good unit under equivalent conditions.
If abnormal behaviour persists, remove the suspected charger from service pending further evaluation.
A USB tester can reveal symptoms but cannot independently identify every internal power supply fault.
11. USB Cable Resistance Testing in Repair Workshops
USB cables are frequently responsible for charging complaints.
The FNIRSI FNAC-28 provides supported cable resistance testing functions.
Electrical resistance causes voltage drop when current flows.
The basic formula is:
Voltage Drop = Current x Resistance
For example:
Current: 2A
Cable path resistance: 0.20 ohm
Voltage Drop = 0.40V
Higher resistance may contribute to reduced voltage at the connected device.
However, cable resistance alone does not establish complete USB-C compliance or suitability for high-power charging.
Workshop Recommendation
Compare suspected cables with compatible known-good cables using consistent test conditions.
Record the results where useful.
12. Fast-Charging Protocol Testing for Repair Shops
Modern smartphones may use different fast-charging technologies.
Examples include:
Qualcomm Quick Charge
Samsung AFC
Huawei FCP
Huawei SCP
Selected Proprietary Fast-Charging Systems
USB Power Delivery
USB PD PPS
The FNIRSI FNAC-28 provides selected non-PD protocol testing functions.
However, it does not support USB PD active triggering or PD packet capture.
When Advanced Equipment Is Needed
A dedicated USB PD analyser may be necessary when investigating:
USB PD negotiation failures
PPS compatibility problems
Detailed power contract information
PD communication errors
Advanced USB-C charging behaviour
Select diagnostic equipment according to the charging technology being investigated.
13. How to Create a Simple USB Charging Test Report
Repair shops can use a standardised report to document charging complaints.
Suggested Test Report Format
ItemInformation to RecordCustomer ReferenceJob NumberDeviceBrand and ModelComplaintReported Charging ProblemChargerBrand and Output RatingCableConnector Type and ConditionTest EquipmentFNIRSI FNAC-28Measured VoltageVMeasured CurrentAMeasured PowerWTest ConditionsBattery Level, Load and TemperatureCorrective ActionCable Replacement or Further DiagnosisFinal ResultObservations After Testing
A report does not need to be complicated.
Consistent documentation makes it easier to compare results and explain technical findings to customers.
14. Improving Workshop Efficiency with Standardised Testing
A standard test procedure can help repair shops organise their diagnostic work.
Potential benefits include:
More Consistent Troubleshooting
Clearer Customer Explanations
Better Repair Documentation
Reduced Unnecessary Component Replacement
Easier Comparison Between Technicians
More Reliable Before-and-After Measurements
However, the effectiveness of the procedure depends on technician training, appropriate test equipment and correct interpretation.
A USB tester should be considered one component of a complete electronics repair workflow.
15. Recommended Supporting Equipment for USB Repair Work
The FNIRSI FNAC-28 may be used alongside other instruments and accessories.
EquipmentMain PurposeFNIRSI FNAC-28USB Voltage, Current and Power MonitoringDigital MultimeterGeneral Electrical MeasurementsUSB Electronic LoadControlled Charger LoadingKnown-Good USB CablesCable ComparisonKnown-Good USB ChargersCharger ComparisonUSB PD AnalyserAdvanced USB-C PD InvestigationSuitable Battery Diagnostic EquipmentBattery Condition AssessmentInspection ToolsConnector and Physical Damage Checks
Not every workshop needs all these instruments.
Equipment selection should depend on the types of devices serviced and the complexity of the repairs.
16. Safety Precautions for Electronics Repair Shops
Before testing USB charging equipment:
Inspect Chargers and Cables
Do Not Use Visibly Damaged Equipment
Confirm Voltage and Current Limits
Use Compatible USB Connections
Avoid Short Circuits
Use Properly Rated Electronic Loads
Do Not Bypass Safety Protection
Stop Testing if Equipment Overheats
Follow Manufacturer Instructions
The FNIRSI FNAC-28 is designed for compatible low-voltage USB measurements.
Never connect it directly to AC mains or circuits outside its specified operating limits.
17. Is FNIRSI FNAC-28 Suitable for Small Repair Workshops?
For workshops handling common USB charging complaints, the FNIRSI FNAC-28 can provide useful preliminary measurements.
It is particularly relevant for:
Mobile Phone Repair Shops
Electronics Repair Workshops
Computer Service Centres
USB Charger Retailers
Power Bank Service Businesses
Electronics Training Centres
Its practical value comes from helping technicians observe charging behaviour and compare equipment under consistent conditions.
However, it is not a replacement for advanced battery diagnostics, internal circuit troubleshooting or complete USB PD analysis.
18. Where to Buy FNIRSI FNAC-28 for Repair Shops in Malaysia?
MTM Precision Sdn Bhd supplies electronic testing and measuring instruments for technical and professional applications.
Customers looking for a FNIRSI FNAC-28 USB Charger Tester Malaysia can contact MTM Precision for product pricing, availability and suitable instrument recommendations.
The FNAC-28 can be useful for workshops interested in USB charging diagnostics, cable resistance testing, charger comparisons and power bank output measurements.
MTM Precision serves customers in Kuala Lumpur, Selangor, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak.
Please contact our team to confirm current stock and delivery arrangements.
Frequently Asked Questions
Q1. Is FNIRSI FNAC-28 suitable for mobile phone repair shops?
Yes. It can assist with preliminary USB charging measurements and accessory troubleshooting.
Q2. Can FNIRSI FNAC-28 identify a faulty charger?
It can reveal abnormal electrical behaviour, but further testing may be necessary to confirm the fault.
Q3. Can FNIRSI FNAC-28 test USB charging cables?
Yes. It provides supported cable resistance testing and compatible USB electrical measurements.
Q4. Can FNIRSI FNAC-28 diagnose smartphone battery health?
No. It is not a complete smartphone battery health analyser.
Q5. Can FNIRSI FNAC-28 test fast-charging protocols?
It supports selected non-PD fast-charging protocol functions.
Q6. Does FNIRSI FNAC-28 support USB PD active triggering?
No. USB PD active triggering and PD packet capture are not supported.
Q7. Can repair shops use FNIRSI FNAC-28 for before-and-after testing?
Yes. Technicians can compare compatible USB measurements before and after corrective action under similar conditions.
Q8. Where can I enquire about FNIRSI FNAC-28 in Malaysia?
Contact MTM Precision Sdn Bhd in Puchong, Selangor, for pricing and availability.
Contact MTM Precision Sdn Bhd
For FNIRSI FNAC-28 USB Tester Malaysia, electronics repair workshop equipment and USB charging diagnostic instrument enquiries:
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for FNIRSI FNAC-28 pricing, availability and suitable USB diagnostic equipment recommendations in Malaysia.
Conclusion
Electronics repair shops benefit from a consistent approach to USB charging diagnosis.
The FNIRSI FNAC-28 USB Tester provides useful voltage, current and power measurements that can support preliminary fault isolation, charger comparisons and repair verification.
By combining customer complaint records, visual inspection, electrical measurements, controlled comparisons and final testing, technicians can make more informed repair decisions.
For customers searching for Electronics Repair Tools Malaysia, USB Charger Tester for Repair Shops Malaysia or FNIRSI FNAC-28 Malaysia, MTM Precision Sdn Bhd can assist with product enquiries and suitable testing equipment selection.
10 Oct 2026