How to Check Steel Tank Wall Thickness Using Benetech Ultrasonic Thickness Gauge Malaysia
How to Check Steel Tank Wall Thickness Using Benetech Ultrasonic Thickness Gauge Malaysia
Introduction
Steel storage tank wall thickness inspection is an important maintenance activity in manufacturing factories, water treatment facilities, chemical processing plants and industrial operations throughout Malaysia.
Steel storage tanks are commonly used to store water, industrial liquids, process materials and other substances. Over time, tank walls may experience corrosion, erosion, mechanical wear and material thinning.
If deterioration is not identified and properly assessed, excessive wall thinning may contribute to leakage, structural damage or equipment failure.
A portable Ultrasonic Thickness Gauge allows maintenance technicians to measure the thickness of suitable metal tank walls from one accessible side without cutting the material.
The Benetech GM100 Plus and Benetech GM130 Ultrasonic Thickness Gauges are two instruments available from MTM Precision Sdn Bhd Malaysia for general industrial thickness measurement applications.
This guide explains how to inspect steel storage tank wall thickness, select suitable measurement locations, understand thickness readings and choose between the GM100 Plus and GM130.
1. Why Is Steel Tank Wall Thickness Inspection Important?
Industrial storage tanks are exposed to different operating and environmental conditions.
Depending on the stored material and operating environment, corrosion may develop on the internal or external tank surfaces.
Common factors contributing to tank deterioration include:
Moisture and Condensation
Chemical Exposure
Internal Corrosion
External Corrosion
Coating Deterioration
Long-Term Environmental Exposure
Mechanical Wear
Localized Pitting Corrosion
Benefits of Regular Thickness Inspection
Early Identification of Wall Thinning
Repeated thickness measurements may help identify locations where the tank wall is becoming thinner.
Preventive Maintenance Planning
Inspection records can support decisions about additional inspection, maintenance and repair.
Reduced Unnecessary Dismantling
Ultrasonic measurement can often be performed from the external surface without cutting or dismantling the tank.
Improved Equipment Monitoring
Recorded measurements allow technicians to compare wall thickness at established inspection locations.
Support for Tank Integrity Assessment
Thickness data can provide useful input for qualified engineering assessment.
However, ultrasonic thickness measurement alone does not determine whether a storage tank is safe for continued operation.
The results must be evaluated against applicable engineering requirements and inspection procedures.
2. What Is an Ultrasonic Thickness Gauge?
An Ultrasonic Thickness Gauge is a non-destructive testing instrument used to measure the thickness of suitable solid materials.
The instrument transmits ultrasonic sound pulses through the material using a probe.
When the sound reaches a suitable reflecting boundary, part of the ultrasonic energy returns to the probe.
The instrument calculates material thickness using the sound velocity and measured echo travel time.
Basic Measurement Formula
Thickness = Sound Velocity × Echo Travel Time / 2
For steel storage tank inspection, the operator must select an appropriate ultrasonic sound velocity for the tank material.
Incorrect sound velocity settings may produce inaccurate thickness readings.
Why Ultrasonic Measurement Is Useful for Tanks
Unlike conventional calipers, an ultrasonic thickness gauge can measure suitable tank wall thickness from one accessible side.
This is particularly useful when the internal tank surface is difficult to access.
However, reliable measurement requires suitable surface preparation, ultrasonic coupling, instrument verification and probe selection.
3. Benetech GM100 Plus and GM130 Specifications
Both instruments are suitable for general ultrasonic thickness measurement.
SpecificationGM100 PlusGM130Steel Measurement Range1.2–300 mm1.0–300 mmWorking Frequency5 MHz5 MHzSound Velocity Range1000–9999 m/s1000–9999 m/sAutomatic CalibrationYesYesLinear Automatic CompensationYesNoThickness Value StorageYesYesThickness AlarmNoYesMeasurement Mode SelectionNoYesMetric / Imperial ConversionNoYes6 mm Probe SupportNoYes10 mm Probe SupportYesYes
Important: The specified measurement ranges are based on the manufacturer's steel reference conditions. Actual performance depends on material, probe, surface condition and inspection geometry.
Benetech GM100 Plus
The GM100 Plus Ultrasonic Thickness Gauge is suitable for routine thickness measurement of steel plates, accessible storage tank walls and industrial metal components.
Benetech GM130
The GM130 Ultrasonic Thickness Gauge offers additional features including upper and lower thickness alarms, measurement mode selection and compatible 6 mm and 10 mm probe options.
These features may be useful for maintenance teams performing repeated thickness screening at multiple inspection locations.
4. Common Types of Steel Storage Tanks
Different storage tank designs may require different inspection approaches.
Water Storage Tanks
Steel water storage tanks are used in factories, industrial facilities and water treatment operations.
Potential inspection concerns include internal corrosion, external corrosion and wall thickness reduction.
Chemical Storage Tanks
Chemical storage tanks may be exposed to corrosive liquids or vapours.
Thickness inspection requirements depend on the stored chemical, tank material and operating conditions.
Industrial Process Tanks
Manufacturing facilities use tanks for various production and process applications.
Periodic wall thickness monitoring may support maintenance planning.
Fuel and Oil Storage Tanks
Metal tanks used for fuel or oil storage may require specialized inspection procedures and strict safety controls.
Important Safety Note: The GM100 Plus and GM130 should not be assumed to have intrinsically safe or explosion-proof certification.
They must not be used in classified hazardous areas unless their suitability has been formally established under applicable site requirements.
Steel Fabricated Tanks
Fabricated steel tanks may require thickness verification during manufacturing, maintenance or inspection.
5. Where Should You Measure Storage Tank Wall Thickness?
Selecting appropriate measurement locations is essential for meaningful tank inspection.
For a typical accessible steel storage tank, inspection locations may include:
Tank Shell
The tank shell forms the main vertical wall of many storage tanks.
Measurements may be taken at selected elevations and circumferential positions according to the inspection plan.
Lower Shell Sections
Lower tank wall areas may be exposed to moisture, deposits or other conditions associated with corrosion.
These areas may require additional inspection attention depending on the tank design and operating history.
Areas Showing Visible Corrosion
Locations with rust, coating damage or visible deterioration may justify further investigation.
Weld-Adjacent Areas
Selected areas near welds may require inspection depending on the tank design and applicable procedure.
Measurements close to welds can be affected by geometry and material conditions, so appropriate techniques must be used.
Tank Bottom and Floor
Tank bottoms may experience corrosion, but their inspection can be more complicated.
A handheld ultrasonic thickness gauge used at a few accessible locations cannot establish the overall condition of an entire tank bottom.
Tank floor inspection may require specialized scanning methods, qualified inspection personnel and a suitable inspection plan.
6. Step-by-Step Guide to Steel Tank Wall Thickness Measurement
Step 1 - Review the Tank Information
Before measurement, identify:
Tank Material
Tank Design
Expected Wall Thickness
Operating Conditions
Inspection Locations
Previous Thickness Records
For critical tanks, the inspection plan should be established by qualified personnel.
Step 2 - Confirm Site Safety
Check whether the tank area has special safety requirements.
Potential hazards include:
Flammable vapours
Hazardous chemicals
Hot surfaces
Elevated working locations
Confined spaces
Pressurized equipment
Do not use the instrument in hazardous environments unless its suitability has been verified.
Step 3 - Prepare the Measurement Surface
Remove loose rust, dirt, scale and contaminants that interfere with ultrasonic coupling.
If protective coating removal is necessary, follow the approved site procedure.
Step 4 - Check the Instrument
Switch on the Benetech GM100 Plus or Benetech GM130.
Verify the probe connection, battery condition and instrument settings.
Step 5 - Verify Calibration
Check the instrument using a suitable known-thickness reference according to the manufacturer's instructions.
For reliable results, the reference should be appropriate for the material and measurement range.
Step 6 - Set the Sound Velocity
Configure the correct ultrasonic sound velocity for the tank material.
Different materials transmit ultrasonic waves at different speeds.
Step 7 - Apply Ultrasonic Coupling Gel
Apply suitable ultrasonic coupling agent to the selected measurement point.
Coupling gel helps transmit ultrasonic energy between the probe and steel surface.
Step 8 - Position the Probe
Place the probe firmly against the tank wall.
Maintain stable contact and check the coupling indication.
Step 9 - Record the Thickness
Observe the displayed thickness value.
Repeat the measurement where necessary to confirm consistency.
Step 10 - Document the Results
Record the following information:
Tank identification
Measurement location
Material type
Instrument model
Probe used
Measurement date
Thickness reading
Relevant surface conditions
Consistent measurement locations and documentation are essential for reliable long-term corrosion monitoring.
7. Example of Steel Storage Tank Thickness Inspection
Consider a hypothetical steel water storage tank undergoing routine maintenance inspection.
The maintenance team measures the tank wall at five selected locations.
Inspection LocationMeasured ThicknessUpper Shell A6.1 mmMiddle Shell B5.9 mmLower Shell C5.3 mmLower Shell D4.8 mmMiddle Shell E5.7 mm
These values are illustrative examples and are not actual field measurements.
The lowest recorded thickness is 4.8 mm at Lower Shell D.
This location may require additional measurement or engineering assessment.
However, the lowest thickness does not automatically mean the tank is unsafe.
Important Engineering Considerations
The acceptable remaining thickness depends on:
Tank material
Original design thickness
Tank dimensions
Stored liquid
Operating conditions
Corrosion allowance
Applicable design and inspection standards
Minimum allowable thickness must be determined by qualified engineering assessment, not by the ultrasonic thickness gauge alone.
8. Using GM130 Thickness Alarm for Tank Inspection
The Benetech GM130 includes upper and lower thickness alarm settings.
This feature may help technicians screen multiple measurement locations against predefined limits.
Example
Suppose an engineer establishes a lower inspection screening threshold of 5.0 mm for a particular tank component.
The technician configures the GM130 lower alarm setting according to the approved inspection requirement.
Thickness ReadingScreening Result6.0 mmAbove threshold5.5 mmAbove threshold5.0 mmAt threshold4.7 mmBelow threshold
This is an illustrative example only. The 5.0 mm value is not a universal minimum safe tank thickness.
Benefits of GM130 Thickness Alarm
Convenient Screening of Multiple Locations
Faster Identification of Out-of-Range Readings
Support for Routine Maintenance Inspection
Improved Consistency During Initial Thickness Checks
The alarm function helps with screening but does not replace engineering judgment.
9. GM100 Plus vs GM130 for Storage Tank Inspection
Which model should a maintenance technician choose?
Choose Benetech GM100 Plus If:
You need routine steel tank wall thickness measurement.
You mainly inspect accessible flat metal surfaces.
You require general thickness verification.
You do not require configurable thickness alarms.
You prefer straightforward measurement operation.
Choose Benetech GM130 If:
You need upper and lower thickness alarm settings.
You require measurement mode selection.
You need metric and imperial unit conversion.
You want compatible 6 mm and 10 mm probe options.
You perform varied industrial thickness inspection tasks.
For routine tank wall measurement, the GM100 Plus may be sufficient. For additional screening features and probe flexibility, consider the GM130.
10. Can GM100 Plus and GM130 Measure Painted Tank Walls?
Many industrial storage tanks have protective paint or coating systems.
These coatings help protect steel surfaces against environmental exposure and corrosion.
However, surface coatings may affect ultrasonic thickness readings.
The Benetech GM100 Plus and GM130 should not be assumed to provide specialized through-coating steel thickness measurement.
Where the inspection procedure requires substrate thickness measurement without removing coatings, a suitable through-coating ultrasonic thickness gauge may be necessary.
For conventional measurements, coating removal at approved inspection locations may be required.
Always confirm the measurement requirements before selecting an instrument.
11. Common Problems During Tank Wall Thickness Measurement
Problem 1 - No Thickness Reading
Possible causes:
Insufficient coupling gel
Poor probe contact
Incorrect instrument settings
Unsuitable surface condition
Probe connection problems
Solution: Check the probe connection, prepare the measurement surface and verify instrument settings.
Problem 2 - Unstable Thickness Readings
Possible causes:
Rough steel surface
Corrosion irregularities
Poor ultrasonic coupling
Inconsistent probe positioning
Material structure differences
Solution: Improve surface preparation and repeat the measurement using a suitable inspection procedure.
Problem 3 - Incorrect Thickness Reading
Possible causes:
Incorrect sound velocity
Calibration problems
Unsuitable reference sample
Surface coating interference
Incorrect probe selection
Solution: Verify the instrument using an appropriate reference and confirm the material properties.
Problem 4 - Different Thickness Readings Across the Tank
Possible causes:
Actual thickness variation
Localized corrosion
Different original plate thicknesses
Surface condition differences
Measurement uncertainty
Solution: Record measurement locations carefully and investigate significant differences according to the inspection procedure.
Problem 5 - Difficulty Measuring Corroded Surfaces
Severely corroded surfaces may produce unreliable ultrasonic signals.
Solution: Use appropriate surface preparation and measurement techniques. Specialized NDT equipment may be necessary for complex corrosion conditions.
12. How Often Should Steel Storage Tanks Be Inspected?
There is no single inspection interval suitable for every steel storage tank.
The appropriate inspection schedule depends on:
Tank Design
Stored Material
Operating Conditions
Corrosion Risk
Previous Inspection Results
Applicable Standards
Regulatory Requirements
For example, a tank exposed to aggressive chemical conditions may require a different inspection schedule from a tank storing relatively non-corrosive water.
Recommended Maintenance Approach
Baseline Inspection
Establish initial wall thickness measurements at defined locations.
Periodic Monitoring
Repeat measurements according to an approved inspection schedule.
Trend Comparison
Compare readings collected at the same locations over time.
Further Assessment
Investigate significant reductions or unexpected readings.
Maintenance Planning
Use the findings to support repair, replacement or further inspection decisions.
For tanks governed by specific industry codes, inspection intervals and acceptance criteria must follow the applicable requirements.
13. Industrial Applications Across Malaysia
The Benetech GM100 Plus and GM130 Ultrasonic Thickness Gauges are relevant to various industrial maintenance applications in Malaysia.
Selangor and Kuala Lumpur
Manufacturing factories, industrial storage tanks, engineering workshops and maintenance contractors.
Johor
Industrial plants, fabrication facilities, water treatment equipment and tank maintenance.
Penang and Kedah
Manufacturing operations, industrial equipment and mechanical maintenance.
Melaka and Negeri Sembilan
Factory storage tanks, industrial process equipment and maintenance applications.
Perak and Pahang
Industrial facilities, metal fabrication and storage equipment inspection.
Terengganu and Kelantan
Industrial maintenance and suitable petrochemical equipment thickness measurement.
Sabah and Sarawak
Industrial facilities, metal storage equipment and engineering maintenance.
Customers in Perlis may also require portable ultrasonic thickness gauges for general industrial applications.
14. Frequently Asked Questions
Q1. How do you measure steel storage tank wall thickness?
A suitable ultrasonic thickness gauge can measure steel wall thickness from one accessible side using ultrasonic sound waves.
The operator must prepare the surface, verify the instrument, configure the correct sound velocity and use suitable coupling gel.
Q2. Can Benetech GM100 Plus measure tank wall thickness?
Yes. The GM100 Plus can measure suitable steel tank wall thickness when the application falls within its verified measurement capability.
Q3. Is Benetech GM130 better for corrosion monitoring?
The GM130 offers additional features such as thickness alarm settings and compatible probe options.
These features may be useful for repeated thickness screening.
Q4. Can ultrasonic thickness gauges detect tank corrosion?
They can help identify possible corrosion-related wall thinning.
However, they do not automatically detect every corrosion defect or determine the overall condition of a tank.
Q5. Can GM130 measure through tank paint?
Do not assume that the GM130 provides specialized through-coating thickness measurement.
The application may require a different instrument or approved coating removal.
Q6. Can ultrasonic thickness gauges measure tank bottoms?
They may measure suitable accessible areas, but comprehensive tank floor inspection often requires specialized procedures and equipment.
Q7. Is ultrasonic thickness measurement destructive?
No. Ultrasonic thickness measurement is a non-destructive testing method when performed appropriately.
Surface preparation or coating removal may still be required.
Q8. Which model is suitable for routine steel tank inspection?
The GM100 Plus is suitable for general thickness measurement, while the GM130 offers additional alarm and probe options.
Q9. Where can I buy a Benetech Ultrasonic Thickness Gauge in Malaysia?
MTM Precision Sdn Bhd supplies Benetech GM100 Plus and GM130 Ultrasonic Thickness Gauges for industrial testing and maintenance applications in Malaysia.
15. Buy Benetech Ultrasonic Thickness Gauge for Storage Tank Inspection Malaysia
Looking for a reliable Steel Tank Wall Thickness Measurement Instrument in Malaysia?
MTM Precision Sdn Bhd supplies industrial testing and measuring instruments for factories, engineering contractors, maintenance departments and industrial inspection applications.
We supply:
Benetech GM100 Plus Ultrasonic Thickness Gauge
Suitable for routine thickness measurement of compatible steel plates, tank walls and industrial metal components.
Benetech GM130 Ultrasonic Thickness Gauge
Offers additional thickness alarm settings, measurement mode selection and compatible probe options.
Need Help Choosing the Right Ultrasonic Thickness Gauge?
Please provide:
Tank Material
Expected Wall Thickness
Tank Surface Condition
Tank Dimensions
Inspection Application
Probe Requirements
Special Measurement Requirements
Customers may also send photographs of the tank or measurement area through WhatsApp for preliminary product selection assistance.
Contact MTM Precision Sdn Bhd
MTM PRECISION SDN BHD
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for Benetech GM100 Plus and GM130 Ultrasonic Thickness Gauge enquiries, availability and quotations in Malaysia.
11 Oct 2026