How to Choose an Air Purifier for Haze and PM2.5 in Malaysia
How to Choose an Air Purifier for Haze and PM2.5 in Malaysia
During haze episodes in Malaysia, many homeowners, office managers and parents consider purchasing an air purifier to improve indoor air quality.
However, choosing an effective air purifier for haze and PM2.5 involves more than selecting a popular brand or checking the advertised room coverage.
Some compact air purifiers may be suitable for small bedrooms but insufficient for larger living rooms, classrooms or shared offices.
Others may advertise HEPA filtration without providing clear information about particle Clean Air Delivery Rate (CADR).
For customers in Kuala Lumpur, Selangor, Johor, Penang and other Malaysian states, understanding the differences between HEPA filters, CADR, room volume, air changes per hour and filter maintenance can help avoid unsuitable purchases.
This guide explains how to choose an air purifier for haze, how to estimate the required clean-air delivery and how to observe changes in indoor PM2.5 using a portable air quality monitor such as the Temtop S1 Up.
MTM Precision Sdn Bhd supplies portable air quality monitoring instruments in Malaysia for homes, offices, schools and commercial applications.
1. Why Use an Air Purifier During Haze?
Haze may contain elevated concentrations of fine airborne particles, including PM2.5.
These particles can enter buildings through windows, doors, ventilation systems and building air leakage.
Once indoors, particles may remain suspended in the air until they are removed through filtration, ventilation or deposition onto surfaces.
A suitable air purifier can help reduce airborne particulate concentrations.
However, its effectiveness depends on:
Verified particle CADR
Room volume
Airflow distribution
Filter efficiency
Fan speed
Outdoor particle infiltration
Indoor pollution sources
Maintenance condition
An air purifier can help reduce airborne particles, but it cannot guarantee completely pollution-free indoor air.
2. What Is PM2.5?
PM2.5 refers to airborne particles with an aerodynamic diameter of 2.5 micrometres or smaller.
Common sources include:
Forest and peatland fires
Open burning
Vehicle exhaust
Industrial combustion
Cigarette smoke
Cooking emissions
Other combustion activities
PM2.5 concentration is generally expressed in micrograms per cubic metre (µg/m³).
Exposure to elevated fine particulate concentrations is associated with respiratory and cardiovascular health effects.
Because fine particles are not reliably visible to the naked eye, a suitable PM2.5 monitor can help users observe indoor particulate changes.
PM2.5 monitoring is useful when evaluating particulate conditions during haze.
3. What Features Matter Most When Buying an Air Purifier?
Before buying an air purifier, evaluate the following factors:
FeatureWhy it mattersParticle CADRIndicates the purifier's tested clean-air deliveryFilter efficiencyDetermines particle capture performance under specified conditionsRoom volumeAffects required clean-air deliveryFan speedInfluences actual airflow and noiseAirflow distributionAffects how clean air reaches occupied areasFilter replacementInfluences maintenance costNoise levelImportant for bedrooms and officesEnergy consumptionImportant for extended operationOzone emissionsImportant when evaluating electronic air-cleaning featuresProduct supportHelps with filter availability and maintenance
For haze-related particulate removal, verified particle CADR and effective filtration are among the most important specifications.
4. What Is a HEPA Filter?
HEPA stands for High Efficiency Particulate Air.
A genuine HEPA filter is designed to capture airborne particles under defined testing conditions.
HEPA filters are widely used in particulate filtration applications.
However, consumers should distinguish between:
Genuine HEPA filters
HEPA-type filters
HEPA-like marketing descriptions
Unverified filtration claims
Different standards may specify different test methods and efficiency classifications.
For example, under EN 1822 or ISO 29463 classification systems, an H13 filter is associated with high particle filtration efficiency at the most penetrating particle size.
However, the filter's efficiency rating alone does not establish the air purifier's total room-level performance.
A high-efficiency filter combined with insufficient airflow may still provide inadequate clean-air delivery for a large room.
5. HEPA H13 vs Ordinary Air Purifier Filters
ComparisonHEPA H13 filterBasic or unverified filterParticle filtration classificationDefined under relevant test standardsMay not have a recognised HEPA classificationEfficiency evidenceRequires appropriate test documentationDepends on manufacturer claimsFine particle captureHigh efficiency under specified test conditionsVariesWhole-room performanceDepends on purifier airflow and designDepends on purifier airflow and designMaintenanceRequires suitable replacementRequires suitable replacement
A genuine HEPA H13 filter may be beneficial for particulate filtration.
However, customers should verify that the claimed filter classification is supported by appropriate documentation.
HEPA classification and CADR are different specifications and should both be considered.
6. What Is CADR?
Clean Air Delivery Rate (CADR) describes the rate at which an air cleaner delivers air cleaned of a specified pollutant under a defined test method.
CADR is commonly expressed in:
Cubic metres per hour (m³/h)
For example:
CADR 100 m³/h
CADR 200 m³/h
CADR 300 m³/h
CADR 500 m³/h
A higher verified particle CADR generally indicates greater particulate cleaning capacity under the specified test conditions.
However, actual room performance also depends on placement, airflow, pollution sources and building conditions.
When choosing an air purifier for PM2.5, check the verified particle CADR rather than relying only on the advertised coverage area.
7. Particle CADR vs Gas CADR
Some air purifiers advertise separate performance figures for particulate and gaseous pollutants.
These specifications should not be confused.
Particle CADR
Describes clean-air delivery for specified particulate pollutants under a defined test method.
Gas Removal Performance
Describes performance against particular gaseous pollutants under applicable test conditions.
A purifier with strong particle CADR does not automatically provide strong formaldehyde, VOC or ozone removal.
Similarly, a gas-phase filter does not automatically provide high PM2.5 removal performance.
For haze-related PM2.5, prioritise verified particle CADR and effective particulate filtration.
8. How to Calculate Room Volume
Room volume is an important factor when selecting an air purifier.
The basic formula is:
Room Volume = Length × Width × Ceiling Height
For example:
A bedroom measures:
Length: 4 metres
Width: 3 metres
Ceiling height: 2.8 metres
Room volume:
4 × 3 × 2.8 = 33.6 m³
This figure can be used to estimate the clean-air delivery required for a chosen equivalent air-cleaning rate.
Room volume provides a more useful starting point than floor area alone when evaluating air purifier capacity.
9. What Is Air Changes per Hour?
Air Changes per Hour (ACH) describes how many times the air volume of a room is exchanged or supplied as equivalent clean air over one hour.
For a portable air purifier, a simplified equivalent clean-air rate can be estimated using:
Equivalent Clean-Air Changes per Hour = Particle CADR / Room Volume
For example:
Particle CADR = 200 m³/h
Room volume = 40 m³
200 / 40 = 5 equivalent clean-air changes per hour
This is a simplified calculation.
It assumes the rated CADR applies to the operating setting and does not fully account for imperfect air mixing, filter condition or ongoing particle sources.
Equivalent clean-air changes are not the same as outdoor fresh-air ventilation changes.
A recirculating purifier can remove particles without providing fresh outdoor air.
10. How Much CADR Does Your Room Need?
The following table illustrates particle CADR values corresponding to a selected target of approximately five equivalent clean-air changes per hour.
These are calculation examples, not guaranteed purifier requirements for every room.
Room volumeIllustrative particle CADR20 m³100 m³/h30 m³150 m³/h40 m³200 m³/h60 m³300 m³/h80 m³400 m³/h100 m³500 m³/h150 m³750 m³/h
The appropriate target depends on the intended application, existing ventilation and filtration, occupancy and pollution conditions.
Higher clean-air delivery may be needed in certain environments.
Do not treat this table as a universal regulatory requirement or a guarantee of safe PM2.5 levels.
11. Air Purifier Selection for Malaysian Bedrooms
Bedrooms are common locations for air purifier use during haze.
Important considerations include:
Room volume
Particle CADR
Noise level
Filter replacement availability
Energy consumption
Airflow direction
Ease of operation
For example, a bedroom measuring 4 m × 3 m × 2.8 m has a volume of 33.6 m³.
At a hypothetical target of five equivalent clean-air changes per hour:
33.6 × 5 = 168 m³/h
This is an illustrative starting point for comparing particle CADR specifications.
A purifier with higher verified particle CADR may provide additional capacity, depending on operating speed and room conditions.
For bedrooms, consider both particulate cleaning performance and acceptable operating noise.
12. Air Purifier Selection for Living Rooms
Living rooms are often larger and more open than bedrooms.
They may also connect to:
Dining areas
Kitchens
Hallways
Staircases
Other open-plan spaces
An air purifier selected only according to the seating area may be undersized for the connected air volume.
For example:
Living room dimensions:
Length: 6 metres
Width: 5 metres
Ceiling height: 3 metres
Room volume:
6 × 5 × 3 = 90 m³
At a hypothetical target of five equivalent clean-air changes per hour:
90 × 5 = 450 m³/h
Actual needs depend on the layout, infiltration and other sources.
Open-plan spaces require consideration of the connected room volume, not only the floor area directly beside the purifier.
13. Air Purifier Selection for Offices
Office air quality management may be more complex because of occupancy, room layout and ventilation systems.
Consider:
Number of employees
Room volume
Existing HVAC filtration
Outdoor air supply
Air purifier CADR
Airflow distribution
Indoor particle sources
Noise tolerance
For example, a six-person office may require a different filtration arrangement from a small private workstation.
One compact purifier positioned beside a single desk may not adequately clean the entire office.
Where indoor smoking occurs, particulate filtration alone is not an adequate substitute for eliminating tobacco smoke exposure.
The preferred approach is to eliminate indoor smoking and provide suitable ventilation and filtration.
14. Air Purifier Selection for Classrooms
Classrooms may have relatively large air volumes and significant occupancy.
Important considerations include:
Classroom volume
Student seating arrangement
Ventilation
Existing HVAC filtration
Particle CADR
Noise level
Airflow distribution
Maintenance
Safe equipment placement
For example:
Classroom dimensions:
Length: 8 metres
Width: 7 metres
Ceiling height: 3 metres
Room volume:
8 × 7 × 3 = 168 m³
At an illustrative target of five equivalent clean-air changes per hour:
168 × 5 = 840 m³/h
This clean-air delivery may be provided through an appropriate combination of filtration systems, depending on the building arrangement.
Schools should follow relevant education, health and building guidance when planning classroom air cleaning and ventilation.
15. One Large Air Purifier vs Two Smaller Air Purifiers
Some customers ask whether one large purifier is better than two smaller units.
The answer depends on total verified particle CADR, room layout and airflow distribution.
For example:
Option A
One purifier with particle CADR of 400 m³/h.
Option B
Two purifiers, each with particle CADR of 200 m³/h.
Both options have a nominal combined particle CADR of 400 m³/h.
However, actual room performance may differ because of:
Equipment placement
Air mixing
Obstructions
Noise levels
Fan settings
Maintenance requirements
Two appropriately positioned units may improve distribution in some rooms.
One larger unit may be simpler to maintain.
Compare total verified clean-air delivery and practical room coverage rather than assuming that more units are automatically better.
16. Can a Desktop Air Purifier Protect an Entire Office?
A desktop air purifier may provide some local particulate cleaning.
However, its ability to reduce PM2.5 throughout an office depends on its particle CADR and the room's characteristics.
For example:
Office volume = 75 m³
Desktop purifier particle CADR = 100 m³/h
Simplified equivalent clean-air changes:
100 / 75 = approximately 1.3 per hour
This may be insufficient for the intended whole-room particulate reduction target.
Placing the purifier close to one workstation does not guarantee uniform protection throughout the office.
A desktop purifier should not be assumed to provide adequate whole-room filtration without considering verified CADR and room volume.
17. Does an Air Purifier Remove Cigarette Smoke?
Cigarette smoke contains both particles and gases.
A suitable particulate air purifier may reduce some airborne smoke particles.
However, particulate filtration does not remove every harmful gas associated with tobacco smoke.
Smoke residues may also remain on indoor surfaces.
Therefore, even when PM2.5 readings decrease, this does not mean all smoke-related pollutants have disappeared.
Eliminating indoor smoking is more effective than relying on an air purifier to manage secondhand smoke exposure.
A portable PM2.5 monitor can observe particulate changes but cannot certify that an indoor smoking environment is safe.
18. Do Ionisers and Negative Ion Air Purifiers Work?
Some air purifiers use ionisation or electrostatic technologies.
Their performance depends on the specific design and verified testing.
Potential considerations include:
Particle removal effectiveness
Ozone emissions
Maintenance requirements
Cleaning mechanisms
Independent performance verification
Some electronic air-cleaning technologies may generate ozone as an unwanted by-product.
Customers should review credible ozone-emission certification and pollutant removal test results where relevant.
Do not assume that a negative-ion feature is equivalent to verified HEPA filtration or high particle CADR.
For haze-related PM2.5 control, independently verified particulate cleaning performance is important.
19. How to Position an Air Purifier Correctly
Air purifier placement can influence its effectiveness.
General considerations include:
Keep air inlets unobstructed.
Avoid blocking the discharge airflow.
Follow manufacturer clearance requirements.
Avoid placing units behind large furniture.
Consider airflow throughout occupied areas.
Keep electrical equipment away from water.
Follow product safety instructions.
Do not place a PM2.5 monitor directly beside the purifier's clean-air outlet when evaluating general room conditions.
Good purifier placement supports effective air circulation and more representative room-level particulate reduction.
20. How to Use Temtop S1 Up to Check Air Purifier Performance
The Temtop S1 Up Air Quality Monitor can help users observe indoor PM2.5 concentration changes during purifier operation.
Step 1 - Select a Representative Monitoring Location
Place the monitor in an occupied area away from the purifier's direct air discharge.
Step 2 - Record Initial PM2.5
Allow readings to stabilise according to the manufacturer's instructions.
Step 3 - Switch On the Air Purifier
Use a consistent operating speed.
Step 4 - Maintain Comparable Conditions
Avoid unnecessary changes in windows, doors and indoor activities.
Step 5 - Record PM2.5 at Intervals
For example:
Monitoring timeHypothetical PM2.5Before purifier operation60 µg/m³After 15 minutes48 µg/m³After 30 minutes35 µg/m³After 45 minutes27 µg/m³After 60 minutes20 µg/m³
These are illustrative readings, not actual Temtop S1 Up test results.
Step 6 - Review the Trend
A decreasing PM2.5 trend may indicate improving particulate conditions at the monitoring location.
However, the change may also be influenced by ventilation, particle deposition and variations in pollution sources.
A portable PM2.5 monitor cannot independently certify HEPA filter efficiency or the purifier's laboratory CADR.
21. Why Is PM2.5 Still High After Using an Air Purifier?
Possible reasons include:
Insufficient CADR
The purifier may be too small for the room.
Outdoor Haze Infiltration
Particles may continue entering the building.
Indoor Pollution Sources
Cooking, smoking or other activities may generate particles.
Poor Placement
Airflow may be restricted.
Filter Maintenance Problems
The filter may be incorrectly installed or overdue for replacement.
High Humidity
Humidity may affect certain optical PM2.5 sensors.
Insufficient Operating Time
The purifier may require more time to influence room-level concentrations.
If PM2.5 remains elevated, investigate the source, room volume, filtration capacity and monitoring conditions rather than immediately assuming the purifier is defective.
22. How Much Does Air Purifier Maintenance Cost?
Air purifier ownership costs include more than the initial purchase price.
Important expenses may include:
Replacement filters
Electricity
Cleaning and maintenance
Possible replacement parts
Long-term product support
For example, a purifier with a low initial price may become expensive if replacement filters are costly or difficult to obtain.
Customers should ask:
How much does a replacement filter cost?
How frequently is replacement recommended?
Are filters available in Malaysia?
What is the power consumption?
Is local warranty support available?
Compare the total cost of ownership rather than only the purchase price.
23. Air Purifier Buying Checklist Malaysia
Buying considerationWhat to checkMain purposePM2.5, dust, odour or other pollutantsParticle CADRVerified m³/h specificationRoom volumeLength × width × heightFilter typeVerified particulate filtrationOperating speedCADR at intended fan settingNoiseSuitable for bedroom or officeEnergy consumptionAppropriate for extended useFilter availabilityReplacement supply in MalaysiaMaintenance costLong-term ownership expenseOzone emissionsRelevant certification for electronic featuresPlacementAdequate airflow clearancePM2.5 monitoringSuitable instrument for observing trends
For haze-related particulate pollution, verified particle CADR, suitable filtration and correct room sizing should be priorities.
24. Frequently Asked Questions
What type of air purifier is suitable for haze in Malaysia?
A purifier with effective particulate filtration and verified particle CADR appropriate for the room can help reduce airborne haze particles.
Is HEPA H13 suitable for PM2.5?
A genuine HEPA H13 filter provides high particulate filtration efficiency under its applicable test standard. Whole-room performance also depends on airflow and purifier design.
What CADR do I need for my bedroom?
Calculate room volume and select an appropriate clean-air delivery target. Consider the purifier's verified CADR at the intended operating speed.
Is a small desktop purifier enough for an office?
It depends on the room volume and the purifier's verified CADR. A small unit may be insufficient for whole-room cleaning.
Can an air purifier remove cigarette smoke?
A suitable purifier can reduce some smoke particles, but it cannot eliminate all harmful smoke pollutants or make indoor smoking safe.
Can a HEPA filter remove ozone?
HEPA filtration primarily targets particles. Ozone requires separate gas-phase control considerations.
Is an ioniser better than a HEPA purifier?
Performance depends on verified testing. Some electronic air-cleaning technologies may generate ozone, so appropriate certification is important.
Can Temtop S1 Up check whether PM2.5 decreases?
Yes. It can be used for general observation of indoor PM2.5 trends according to its supported functions.
Can Temtop S1 Up measure air purifier CADR?
No. A portable PM2.5 monitor cannot independently establish laboratory CADR.
Where can I buy a PM2.5 monitor in Malaysia?
Customers can contact MTM Precision Sdn Bhd in Puchong, Selangor, for Temtop S1 Up pricing and current stock availability.
25. Buy Temtop S1 Up PM2.5 Air Quality Monitor Malaysia
MTM Precision Sdn Bhd supplies portable air quality monitoring instruments for residential, educational, office and commercial applications throughout Malaysia.
Customers who have purchased an air purifier may wish to observe how indoor PM2.5 changes during operation.
The Temtop S1 Up Air Quality Monitor is an option for general indoor particulate monitoring.
Potential applications include:
Home PM2.5 monitoring
Bedroom air purifier observation
Office particulate monitoring
Classroom air quality checks
Haze-related indoor monitoring
Window closure comparisons
General air purifier performance observation
Customers may contact MTM Precision for:
Temtop S1 Up pricing
Current stock availability
Product specifications
Indoor PM2.5 monitoring applications
Air quality monitor comparisons
General product selection assistance
MTM Precision serves customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
Contact MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Want to Check Whether Your Air Purifier Is Reducing PM2.5?
Contact MTM Precision for Temtop S1 Up pricing, stock availability and assistance selecting a suitable portable PM2.5 monitoring instrument.
You may send us your room dimensions, air purifier model, verified CADR or existing PM2.5 readings through WhatsApp for an initial recommendation.
Conclusion
Choosing an effective air purifier for haze and PM2.5 in Malaysia requires more than selecting a popular model or relying on advertised room coverage.
Important factors include verified particle CADR, effective filtration, room volume, airflow distribution, filter maintenance and indoor pollution sources.
A suitable purifier can help reduce airborne particulate concentrations, but it cannot eliminate every pollutant or replace appropriate ventilation.
The Temtop S1 Up Air Quality Monitor can help users observe indoor PM2.5 changes before and during air purifier operation.
However, portable monitoring does not replace laboratory CADR testing or professional indoor air quality assessment.
The best air purifier choice combines suitable clean-air delivery, effective filtration, proper placement, reasonable maintenance costs and practical PM2.5 monitoring.
For PM2.5 Air Quality Monitor Malaysia and Temtop S1 Up Malaysia enquiries, contact MTM Precision Sdn Bhd in Puchong, Selangor.
15 Oct 2026