FABISENSE PTH-282 Series Portable CO and CO2 Detector Buying Guide Malaysia
The FABISENSE PTH-282 series offers four portable detector configurations: PTH-282A, PTH-282B, PTH-282A+ and PTH-282B+. The main differences are carbon dioxide measurement and app support.
According to the supplied manufacturer catalogue, all four models measure carbon monoxide, temperature and humidity. The B variants add CO2 measurement, while the Plus variants add app support and a time function.
FABISENSE PTH-282 Model Comparison
Choose the model by its complete name, including the A, B and Plus suffix.
FeaturePTH-282APTH-282BPTH-282A+PTH-282B+CO measurementYesYesYesYesCO2 measurementNot listedYesNot listedYesTemperatureYesYesYesYesHumidityYesYesYesYesApp supportNoNoYesYesTime functionNoNoYesYesBattery capacity2100 mAh2100 mAh2100 mAh2100 mAh
The page promotes Bluetooth app connection at series level. However, its comparison table specifies app support for PTH-282A+ and PTH-282B+ only.
PTH-282A - CO Monitoring Without App Setup
The FABISENSE PTH-282A is the simplest configuration in the range.
It provides:
CO measurement from 0–1000 ppm
Temperature readings
Relative humidity readings
Rechargeable battery power
On-device display
Consider this model when you need the listed readings directly on the instrument and do not require CO2 measurement or app access.
PTH-282B - CO and CO2 on One Display
The FABISENSE PTH-282B adds CO2 measurement from 400–5000 ppm to the CO, temperature and humidity functions.
This configuration suits buyers who want both gas readings on the device without app setup.
Carbon monoxide and carbon dioxide are separate measurements. Choose the B variant when CO2 is part of your monitoring requirement; CO2 measurement is not listed for the A variants.
PTH-282A+ and PTH-282B+ - App-Enabled Options
The PTH-282A+ combines CO, temperature and humidity measurement with app support and a time function.
The PTH-282B+ adds CO2 measurement, making it the configuration with the most listed functions in this comparison.
Before choosing either Plus model, confirm:
App name and phone compatibility
Bluetooth connection requirements
Historical data viewing
Data storage capacity
Export capability
Whether alerts operate through the app
The catalogue promotes data logging at series level but does not clearly explain which models store readings, how long records are retained or whether export is available.
Measurement Specifications
The supplied catalogue lists the following gas specifications:
ParameterCatalogue specificationCO range - all models0–1000 ppmCO tolerance±5 ppm or ±10%, whichever is greaterCO2 range - B and B+ models400–5000 ppmCO2 tolerance - B and B+ models±(50 ppm + 5% of reading)Humidity range0–95% RHStated humidity tolerance±5% RH
Confirm the manufacturer’s test conditions, response time and calibration instructions when measurement performance is important to the application.
The page promotes electrochemical sensor technology, but does not identify the exact sensor part numbers or the CO2 sensing method. Do not assume NDIR CO2 technology without model-specific confirmation.
Display, Battery and Size
The compact housing includes a 1.8-inch LCD with a listed resolution of 360 × 360.
Shared specifications include:
ParameterCatalogue specificationBattery2100 mAh lithium batteryCharging connectionUSB Type-CHousing materialABSWorking temperature−10°C to 50°CDimensions74 × 74 × 32 mm
Battery runtime, charging time and charging input requirements are not clearly provided on this page. Check the supplied manual before selecting a power source.
Outdoor and Camping Applications
The manufacturer presents the PTH-282 series for outdoor use, including camping, and illustrates a hanging arrangement.
For Malaysian buyers considering camping or recreational use, check environmental protection, alarm behaviour and battery runtime before ordering.
The page uses a waterproof feature icon, but does not state an IP rating. Confirm the permitted exposure to rain, splashes and condensation.
A detector does not make it safe to use fuel-burning equipment inside a tent or other enclosed space. Follow the equipment manufacturer’s outdoor-use instructions and the detector’s installation and operating guidance.
Emergency Light and Apparent Temperature Functions
The catalogue promotes emergency lighting and apparent temperature monitoring at series level.
The model comparison table does not clearly allocate these functions across all four variants or provide detailed performance information.
If either feature affects your buying decision, request a demonstration and confirmation for the exact model. Also ask how apparent temperature is calculated and how it differs from the displayed air temperature.
What to Check About the Alarm
The supplied page does not clearly specify alarm thresholds, response delays, sound output or user-adjustable settings.
Before relying on the detector for an alarm application, request:
CO alarm thresholds and activation times
Audible and visual alert details
Sensor fault and low battery indications
Sensor life and replacement instructions
Functional test and calibration procedures
Applicable model-specific certification
The catalogue alone does not establish suitability as a certified residential CO alarm or an industrial personal gas detector.
Frequently Asked Questions
Which PTH-282 models measure CO2?
The catalogue lists CO2 measurement for PTH-282B and PTH-282B+.
Which models support an app?
The comparison table lists app support for PTH-282A+ and PTH-282B+.
Do all models have Bluetooth?
The series page promotes Bluetooth connectivity, but the table limits app support to the Plus models. Confirm the wireless configuration before ordering.
Can these detectors measure PM2.5 or formaldehyde?
PM2.5 and HCHO measurement are not listed on the supplied page.
Can readings be exported?
Data logging is promoted, but export formats and model-specific storage functions require confirmation.
Are these four-gas detectors?
The listed functions do not include oxygen, hydrogen sulphide or combustible gas measurement. Select equipment according to the gases and approvals required for the task.
Enquire About FABISENSE PTH-282 Detectors Malaysia
Contact MTM Precision Sdn Bhd to compare the PTH-282A, PTH-282B, PTH-282A+ and PTH-282B+.
Share your required gases, app requirements and intended environment so the appropriate configuration can be checked. Buyers in Selangor, Kuala Lumpur, Johor and Penang can enquire about model details and availability, subject to confirmation.
SEO Meta Description
Compare FABISENSE PTH-282A, PTH-282B and Plus detectors in Malaysia. Explore CO, CO2, app support and portable monitoring with MTM Precision.
MTM Precision Sdn Bhd
Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
22 Oct 2026