DITRON 605 Series Long Jaw Digital Calipers | 300mm to 3000mm ID & OD Measurement Malaysia

DITRON 605 Series Long Jaw Digital Calipers


The DITRON 605 series provides large-range digital measurement with long, nib-shaped jaws for suitable inside diameter and outside diameter checks.


The catalogue lists measuring ranges from 0–300mm to 0–3000mm, with jaw lengths from 90mm to 200mm depending on the model. Features include zero-setting, reading preset, millimetre/inch conversion, a fine-adjustment carriage and data hold.


For engineering workshops and inspection departments in Malaysia, select the exact model according to measuring range, jaw reach, component access and required accuracy.


PRODUCT HIGHLIGHTS


• Long, nib-shaped jaws for suitable ID and OD measurements.

• Listed measuring capacities from 300mm to 3000mm.

• Multiple jaw lengths.

• Digital readout.

• Zero-setting at any position.

• Reading preset function.

• Millimetre/inch conversion at any position.

• Fine-adjustment carriage.

• Data hold listed in the catalogue.


MODELS AND SPECIFICATIONS


Jaw lengths below refer to dimension a in the manufacturer’s drawing.


DITRON 605-300/90

Measuring range: 0–300mm

Catalogue-stated accuracy: ±0.04mm

Jaw dimension a: 90mm


DITRON 605-300/100

Measuring range: 0–300mm

Catalogue-stated accuracy: ±0.04mm

Jaw dimension a: 100mm


DITRON 605-300/150

Measuring range: 0–300mm

Catalogue-stated accuracy: ±0.05mm

Jaw dimension a: 150mm


DITRON 605-300/200

Measuring range: 0–300mm

Catalogue-stated accuracy: ±0.05mm

Jaw dimension a: 200mm


DITRON 605-500/100

Measuring range: 0–500mm

Catalogue-stated accuracy: ±0.05mm

Jaw dimension a: 100mm


DITRON 605-500/150

Measuring range: 0–500mm

Catalogue-stated accuracy: ±0.06mm

Jaw dimension a: 150mm


DITRON 605-500/200

Measuring range: 0–500mm

Catalogue-stated accuracy: ±0.08mm

Jaw dimension a: 200mm


DITRON 605-600/100

Measuring range: 0–600mm

Catalogue-stated accuracy: ±0.05mm

Jaw dimension a: 100mm


DITRON 605-600/150

Measuring range: 0–600mm

Catalogue-stated accuracy: ±0.06mm

Jaw dimension a: 150mm


DITRON 605-600/200

Measuring range: 0–600mm

Catalogue-stated accuracy: ±0.08mm

Jaw dimension a: 200mm


DITRON 605-1000/150

Measuring range: 0–1000mm

Catalogue-stated accuracy: ±0.07mm

Jaw dimension a: 150mm


DITRON 605-1000/200

Measuring range: 0–1000mm

Catalogue-stated accuracy: ±0.10mm

Jaw dimension a: 200mm


DITRON 605-1500/150

Measuring range: 0–1500mm

Catalogue-stated accuracy: ±0.11mm

Jaw dimension a: 150mm


DITRON 605-2000/150

Measuring range: 0–2000mm

Catalogue-stated accuracy: ±0.14mm

Jaw dimension a: 150mm


DITRON 605-3000/200

Measuring range: 0–3000mm

Catalogue-stated accuracy: ±0.26mm

Jaw dimension a: 200mm


Specifications above follow the supplied catalogue. Display resolution is not explicitly stated on this page and should be confirmed separately.


CHOOSING THE MEASURING RANGE


300mm Models

Offer the widest selection of jaw lengths on this page: 90mm, 100mm, 150mm and 200mm.


500mm and 600mm Models

Offer 100mm, 150mm and 200mm jaw options for different component geometries.


1000mm Models

Offer 150mm or 200mm jaws, with different stated accuracy values.


1500mm and 2000mm Models

Provide larger measuring capacity with listed 150mm jaws.


3000mm Model

Provides the largest listed capacity, with 200mm jaws and ±0.26mm stated accuracy.


Select according to both measuring capacity and tolerance. A larger instrument does not automatically provide higher accuracy.


LONG JAWS AND MEASURING ACCESS


Long jaws can reach measuring surfaces set back from a component edge.


However, jaw dimension a is not a guaranteed usable recess depth. The jaw profile, contact location, adjacent shoulders and available clearance must also be checked.


For example, the 605-1000/150 and 605-1000/200 share a 1000mm measuring range, but differ in jaw length and stated accuracy:


605-1000/150

Jaw dimension a: 150mm

Catalogue-stated accuracy: ±0.07mm


605-1000/200

Jaw dimension a: 200mm

Catalogue-stated accuracy: ±0.10mm


INSIDE AND OUTSIDE MEASUREMENT


The catalogue describes nib-shaped jaws for ID and OD measurement.


Outside Measurement

Use the appropriate inward-facing contacts to measure accessible external dimensions.


Inside Measurement

Use the designated outward-facing contacts according to the manufacturer’s instructions.


Confirm the minimum measurable internal opening and whether an allowance or preset is required for internal readings. The listed range beginning at zero does not establish a zero minimum internal measuring size.


FINE-ADJUSTMENT CARRIAGE


The fine-adjustment carriage supports controlled slider positioning when approaching the measuring surfaces.


Use light, consistent contact force. Fine adjustment does not establish constant-force measurement or improve the stated accuracy.


PRESET, ZERO AND DATA HOLD


Zero-setting allows a selected reference to be established.


The preset function allows a reading to be assigned at a selected position, following the operating instructions. Check the active reference before recording results.


Data hold is also listed. Confirm its operation and inclusion in the supplied configuration when ordering.


These features do not establish wireless data transmission. Bluetooth and computer connectivity are not specified on this page.


APPLICATIONS IN MALAYSIA


The DITRON 605 series can be considered for:


• Large machined rings and housings.

• Fabricated frames and components.

• Accessible flange dimensions.

• Maintenance and replacement-part assessment.

• Incoming inspection of larger components.

• Recessed measuring surfaces requiring longer jaws.


For workshops and factories in Selangor, Kuala Lumpur, Johor and Penang, provide the component dimensions, required contact location and tolerance when selecting a model.


For close-tolerance inspection, assess whether another measuring system is more appropriate.


LARGE-RANGE MEASUREMENT CONDITIONS


The stated accuracy varies from ±0.04mm to ±0.26mm across the listed models.


Long instruments require careful support and alignment. Beam deflection, temperature differences, excessive force and contamination at the contact surfaces can affect results.


Plan how the instrument and component will be supported, particularly for 1500mm, 2000mm and 3000mm measurements.


BASIC MEASURING PROCEDURE


1. Identify the required dimension and contact surfaces.

2. Clean the jaws and workpiece.

3. Check slider movement and the measuring reference.

4. Confirm whether zero or a preset value is active.

5. Support the instrument and component securely.

6. Position the appropriate measuring contacts.

7. Use fine adjustment according to the instructions.

8. Apply light, consistent contact force.

9. Read and record the result.

10. Repeat the measurement to assess consistency.


For internal measurement, apply any manufacturer-specified allowance or preset.


CARE AND STORAGE


• Protect long jaws from bending and impact.

• Keep the beam and sliding surfaces clean.

• Remove chips before bringing the contacts together.

• Avoid measuring hot or moving components.

• Do not use the jaws as levers or clamps.

• Follow the supplied battery and cleaning instructions.

• Store with adequate support for the beam and jaws.

• Check performance against suitable reference standards according to your quality procedure.


The supplied page does not explicitly specify battery type, rechargeable operation, IP protection rating or material grade.


FREQUENTLY ASKED QUESTIONS


What is the largest model listed?

The 605-3000/200 has a listed 0–3000mm measuring range and 200mm jaw dimension a.


What does 605-500/150 mean?

The catalogue lists this model with a 0–500mm measuring range and a 150mm jaw dimension a.


Can the series measure inside and outside dimensions?

Yes. The catalogue describes nib-shaped jaws for ID and OD measurement. Confirm the correct contact surfaces and reading procedure.


Do longer jaws improve accuracy?

No. Some longer-jaw models have larger stated errors than shorter-jaw versions at the same range.


Does it include fine adjustment?

A fine-adjustment carriage is listed.


Can a reading be preset?

Yes. The catalogue lists a reading preset function.


Does it have data hold?

Data hold is listed in the English feature description. Confirm operation in the supplied configuration.


What is the display resolution?

It is not explicitly specified on the supplied page.


Does it support Bluetooth?

Bluetooth connectivity is not specified on this page.


Is a calibration certificate included?

The supplied page does not confirm inclusion of an individual calibration certificate. Specify documentation requirements when requesting a quotation.


SEO META DESCRIPTION


Explore DITRON 605 long jaw digital calipers in Malaysia, with 300mm to 3000mm ranges, ID and OD measurement, preset and fine adjustment.


ENQUIRE ABOUT DITRON 605 LONG JAW DIGITAL CALIPERS


Contact MTM Precision with your required measuring range, jaw reach, quantity and component tolerance. Include a drawing or clear photo showing the intended measuring surfaces.


Please specify any internal measuring allowance, display resolution, data hold or calibration documentation requirements. Availability, final configuration and supplied accessories are subject to confirmation.


MTM Precision Sdn Bhd

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my