Premium Vici LX-1330 Series Precision Lux / FC / Luminance Light Meters in Malaysia | Authorized Solutions by MTM Precision

Premium Vici LX-1330 Series Precision Lux / FC / Luminance Light Meters in Malaysia | Authorized Solutions by MTM Precision

Elevating Industrial Illumination Auditing, Workplace Safety Compliance, Commercial Lighting Design, and Display Luminance Testing Across Malaysian Infrastructure.

High-Precision Optical Diagnostics for Modern Environmental & Industrial Lighting

In modern commercial architecture, industrial manufacturing facilities, cleanrooms, highway safety engineering, and workplace safety (DOSH/JKKP) compliance sectors across Malaysia, precise measurement of light intensity is essential.Ensuring correct illuminance levels prevents visual fatigue, enhances operational safety, optimizes industrial productivity,and verifies compliance with international building standards such as ISO 8995 and MS 1525. Furthermore, evaluating display screen brightness, signage illumination, and light-emitting surfaces demands specialized luminance (cd/m2) testing capabilities.

Shenzhen Vicimeter Technology Co., Ltd. (globally recognized under the Vici brand) engineered the Vici LX-1330 Series Precision Light Meters (featuring the LX-1332B, LX-1334B, and LX-1336B) to deliver high stability, high light resistance, and laboratory-grade optical precision. Covering wide measurement spectra up to 200,000 Lux, 20,000 Foot-Candles (FC), and 200,000 cd/m2, equipped with a silicon photodiode sensor with filter lens, auto zero-adjustment, fast 3 times/second sampling, and cosine angular correction, this series provides complete illumination diagnostic flexibility. Distributed across Malaysia by MTM Precision Sdn. Bhd., these instruments supply local safety auditors, M&E engineers, and facility managers with genuine factory-backed tools built to satisfy international compliance standards.

Flagship Spotlight: Vici LX-1330 Series Light Meters (LX-1332B, LX-1334B, LX-1336B)

The Vici LX-1330 light meter product line provides three specialized optical measurement configurations tailored for distinct illumination and display testing applications:

  • Vici LX-1332B (200,000 Lux / FC Precision Illuminance Meter): A versatile 2000-count handheld Lux meter featuring broad illuminance ranges from 0 to 200,000 Lux, high repeatability (±2%), auto zero-adjustment,Data Hold, and an extended 120cm sensor cable.

  • Vici LX-1334B (High-Precision 200,000 Lux / FC Light Meter): An upgraded illuminance meter featuring enhanced base accuracy (±3.0%+0.5%f.s), dual Lux/FC unit conversion (1 FC=10.76 Lux), and high stability for critical laboratory and cleanroom lighting audits.

  • Vici LX-1336B (Specialized 200,000 cd/m2 Luminance Meter): A dedicated optical luminance meter engineered for measuring surface brightness (10 to 200,000 cd/m2) across screens, LED signage, light boxes, and luminous surfaces.

Technical Specifications & Model Comparison Matrix

Specification / Parameter Vici LX-1332B Vici LX-1334B Vici LX-1336B Key User Benefit
Primary Measurement Unit Lux (lx) / Foot-Candle (FC) Lux (lx) / Foot-Candle (FC) Candela per Square Meter () LX-1332B/34B test illuminance; LX-1336B tests surface brightness.
Lux Measurement Range 0 to 200,000 Lux (4 Ranges) 0 to 200,000 Lux (4 Ranges) N/A (Dedicated Luminance) Wide multi-range coverage for low-light emergency exits to bright sunlight.
FC Measurement Range 20FC / 200FC / 2000FC / 20000FC 20FC / 200FC / 2000FC / 20000FC N/A () Direct Imperial Foot-Candle unit selection for international architectural specifications.
Luminance Range () N/A N/A 10 to 200,000  Direct surface luminance measurement for displays, signs, and light diffusers.
Measurement Accuracy

()

 

()

()

 

()

High precision across all lighting levels with minimal optical drift.
Resolution 0.1 Lux / 1 FC 0.1 Lux / 1 FC 0.1  High-resolution digital display for detecting subtle lighting variations.
Repeatability & Temp Drift  Repeatability; Temp Characteristic:   Repeatability; Temp Characteristic:   Repeatability; Temp Characteristic:  Consistent readings across varying indoor and outdoor thermal environments.
Photoreceptor Sensor Silicon Photodiode with Filter Lens Silicon Photodiode with Filter Lens Silicon Photodiode with Filter Lens Matches spectral response of the human eye (CIE photopic curve).
Sensor Cable Length Approx. 120 cm (Coiled Cable) Approx. 120 cm (Coiled Cable) Approx. 120 cm (Coiled Cable) Allows flexible sensor positioning on work surfaces while holding the meter comfortably.
Sampling Rate & Zero 3 times/second; Auto Zero-Adjustment 3 times/second; Auto Zero-Adjustment 3 times/second; Auto Zero-Adjustment Fast dynamic response with push-button automatic zeroing.
Max Display & Range 2000 Counts; Manual Range 2000 Counts; Manual Range 2000 Counts; Manual Range Precise manual range selection to maximize display resolution.
Power & Auto Power Off 9V Battery (6F22); ~15 min APO 9V Battery (6F22); ~15 min APO 9V Battery (6F22); ~15 min APO Energy-saving battery management with low battery warning.

Detailed Technical Feature Breakdown

  • Precision Silicon Photodiode with Optical Filter Lens

    Equipped with a high-grade silicon photodiode sensor coated with an optical correction filter lens. The sensor is spectral-response corrected to match the human eye's visual sensitivity curve (CIE photopic standard), ensuring exact Lux/FC readings across LED, fluorescent, metal-halide, incandescent, and natural daylight sources.

  • Specialized Luminance Testing Capability (cd/m2 on LX-1336B)

    The LX-1336B provides specialized surface brightness measurement in Candela per square meter (cd/m2) up to 200,000 cd/m2. This enables quality control engineers to measure the surface luminance of LED displays,medical viewing boxes, street signs, and architectural light panels.

  • Automatic Zero-Adjustment & High Temperature Stability

    Features a dedicated push-button Zero ADJ capability to recalibrate baseline zero before critical audits. With a low temperature coefficient (±0.1%/°C), readings remain stable regardless of ambient temperature variations inside air-conditioned plants or outdoor field sites.

  • Separate Sensor with 120cm Extended Coiled Cable

    The optical sensor probe is detached from the main display body and connected via a flexible 120cm coiled cable.This ergonomics allows auditors to place the sensor flat on desks, production benches, or machinery surfaces without casting shadow over the sensor while reading the LCD screen.

  • Dual Unit Conversion (Lux / Foot-Candles)

    Supports one-touch switching between international metric Lux (lx) and US/Imperial Foot-Candles (FC),simplifying audit reporting for multinational manufacturing plants and architectural projects in Malaysia.

  • Fast 3 Times/Second Sampling & Data Hold

    Real-time sampling rate of 3 readings per second captures instant lighting adjustments during luminaire installation.The Data Hold function freezes stable readings on screen for easy logging in dark environments.

Key Industry Applications in Malaysia

Vici LX-1330 series light meters supplied by MTM Precision serve critical commercial, industrial, and safety compliance sectors across Malaysia:

  • Occupational Safety & Health Auditing (DOSH / JKKP Compliance): Verifying workplace illumination levels in factories, warehouses, office spaces, and emergency escape routes to comply with Malaysian Factories and Machinery (Safety, Health and Welfare) Regulations.

  • Commercial Building & Green Building Energy Audits (MS 1525): Measuring indoor light intensity in commercial complexes, hospitals, schools, and offices to optimize energy efficiency and comply with MS 1525 lighting power density standards.

  • Electronics Manufacturing & Cleanroom Quality Control: Checking workstation light levels in semiconductor assembly lines, cleanrooms, and precision inspection stations to reduce operator eye fatigue and assembly defects.

  • Display Screen, LED & Signage Manufacturing (LX-1336B): Measuring surface luminance (cd/m2) for LED video walls, automotive instrument clusters, backlit billboards, and medical X-ray view boxes.

  • Architectural Lighting Design & M&E Engineering: Auditing newly installed LED fixtures, street lighting,stadium floodlights, and commercial showroom lighting arrangements.

Why Choose MTM Precision Sdn. Bhd. as Your Partner in Malaysia?

Partnering with MTM Precision Sdn. Bhd. guarantees local access to authentic testing equipment backed by complete technical support:

  • 100% Guaranteed Authentic Vici Products: Direct factory distribution ensuring genuine instruments that strictly meet manufacturer specifications.

  • Local Warranty & Rapid Technical Service: Local warranty handling eliminates long turnaround times for international repairs.

  • Puchong Showroom & Hands-on Evaluation: Visit our physical facility in Puchong, Selangor to test Vici light meters and optical instruments with our engineering team.

  • Expert Technical Guidance: Knowledgeable sales engineers available to advise on model selection, testing procedures, and quality compliance.

  • ISO Calibration Coordination: Local calibration support to assist businesses in maintaining ISO quality compliance.

Contact & Showroom Details

Contact MTM Precision

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-660 7346

Office Tel: +603-80807172