Professional Langry RH20-A Mortar Rebound Hammer & Testing Anvil Series in Malaysia
Professional Langry RH20-A Mortar Rebound Hammer & Testing Anvil Series in Malaysia
Part I. Langry RH20-A — Mortar Rebound Hammer
Technical Parameters — Langry RH20-A:
-
Model: Langry RH20-A Mortar Rebound Hammer.
-
Measuring Strength Range: 2 to 15 MPa.
-
Standard Impact Energy: 0.196 J.
-
Pointer Length: 20.0 ± 0.2 mm.
-
Friction of Pointer: 0.5 ± 0.1 N.
-
Operating Length of Elastic Tension Spring: 61.5 ± 0.3 mm.
-
Stretch Length of Impact Spring: 75.0 ± 0.3 mm.
-
Bounce Hammer Take-off Position: Scale "0 ~ 1".
-
Calibration Value on Testing Anvil: 74 ± 2.
Technical Advantages:
-
Imported High-Quality Steel Wire: Internal impact spring is manufactured from high-quality imported spring steel wire for superior core elasticity and stability.
-
High-Precision Aluminum Alloy Cylinder: Durable, high-strength aluminum alloy body with precision internal flanges ensures accurate rebound readings.
-
Direct-Reading Scale: Features an easy-to-read, clear pointer scale for quick field verification of mortar strength.
-
Ergonomic Soft Rubber Hand Rest: Soft rubber protective grip provides hand protection and comfortable operation during repetitive testing.
Part II. Langry Testing Anvil Series (GZ I, GZ II, GZ III, GZ IV)
Technical Advantages & Design:
-
Environmentally Friendly Finish: Surface of ordinary models (GZ I / GZ II) treated with high-durability baking paint.
-
Automatic Guidance Cylinder: Features an advanced guide cylinder structure that automatically guides the rebound hammer during the calibration process without manual alignment.
-
High-Quality Tool Steel Core: The anvil core is machined from high-toughness tool steel to resist repeated high-energy impacts.
-
Code-Compliant Modular Weight Design: Lightweight modular design ensures the total steel anvil weight strictly complies with relevant testing standards whether the guide cylinder is attached or removed.
Model Breakdown & Weight Specifications:
-
GZ I Testing Anvil: Total Weight = 20.0 (+0.3 / -0.1) kg. Core Hardness = HRC 60±2.
-
GZ II Testing Anvil: Total Weight = 16.0 (+0.3 / -0.1) kg. Core Hardness = HRC 60±2.
-
GZ III Testing Anvil: Total Weight = 2.40 (+0.02 / -0.02) kg. Core Hardness = HRC 60±2.
-
GZ IV Testing Anvil: Total Weight = 1.05 (+0.02 / -0.01) kg. Core Hardness = HRC 60±2.
Part III. Langry Rebound Hammer Calibration Matrix on Testing Anvils
1. Ultra High-Strength & High-Strength Concrete Hammers (RH550 / RH450)
-
RH550 Rebound Hammer (5.5J): Calibrated on GZ I Anvil — Target Calibration Value: 83 ± 1.
-
RH450 Rebound Hammer (4.5J): Calibrated on GZ I Anvil — Target Calibration Value: 88 ± 2.
2. Standard Concrete & Mortar Hammers (RH225 / RH75 / RH20)
-
RH225 Series (2.207J):
-
Calibrated on GZ II Anvil — Target Value: 80 ± 2.
-
Calibrated on GZ III Anvil — Target Value: 60 ± 2.
-
Calibrated on GZ IV Anvil — Target Value: 41 ± 2.
-
-
RH75 Series (0.735J):
-
Calibrated on GZ II Anvil — Target Value: 74 ± 2.
-
Calibrated on GZ III Anvil — Target Value: 64 ± 3.
-
Calibrated on GZ IV Anvil — Target Value: 56 ± 3.
-
-
RH20 Mortar Hammer (0.196J):
-
Calibrated on GZ II Anvil — Target Value: 74 ± 2.
-
Why Choose MTM Precision in Malaysia?
09 Nov 2026