Professional Langry Pull-off Tester Series (P16, P25, P50) in Malaysia
Professional Langry Pull-off Tester Series (P16, P25, P50) in Malaysia
Part I. Langry P16 & P25 Pull-off Testers
Technical Advantages — P16 & P25
-
Integrated Lightweight Design: Integrates the hydraulic oil pressure system and high-precision digital pressure gauge into a single compact housing made of high-strength aluminum alloy
. -
Built-in Spiral Oil Pump Pressurization: Features an uninterrupted spiral oil pump pressurization system, eliminating the need to unscrew the rocker screw prior to field detection
. -
Peak Holding Function: Automatically retains and displays the peak failure force reached during the pull-off test
. -
High Stability & Portability: Durable aluminum construction ensures long-term field reliability while remaining easy to handle on site
.
Technical Parameters — P16 & P25
-
Stroke of Hydraulic Cylinder: 5 mm
. -
Scope of Work (Force Range):
-
Model P16: 1.6 kN to 16 kN
. -
Model P25: 2.5 kN to 25 kN
.
-
-
Measurement Resolution: 0.001 kN (0.01 MPa, 1 psi)
. -
Measurement Accuracy: EN ISO 7500-1 Class 1 ($\pm 1\%$, measured from 20% of maximum force)
.
Part II. Langry P50 Heavy-Duty Pull-off Tester
Technical Advantages — P50
-
Integrated Aluminum Alloy Construction: Combines the oil pressure system and digital gauge into a high-strength aluminum alloy body that is light, rigid, and aesthetically designed
. -
Loading Speed Prompt: Built-in loading speed prompt guides operators to maintain a steady load rate in full compliance with testing standards
. -
Real-Time Dual Display Screen: Displays the force-time curve and live load value on the same screen, capturing full testing process data
. -
Zero Temperature Drift & High Accuracy: Delivers stable force output, easy calibration, high precision, and zero temperature drift across varying environmental conditions
.
Technical Parameters — P50
-
Model Name: Langry P50 Pull-off Tester
. -
Stroke of Hydraulic Cylinder: 10 mm
. -
Scope of Work (Force Range): 5 kN to 50 kN
. -
Measurement Resolution: 0.001 kN (0.01 MPa, 1 psi)
. -
Measurement Accuracy: EN ISO 7500-1 Class 1 ($\pm 1\%$, measured from 20% of maximum force)
.
Part III. Testing Methods & Application Diagrams
-
Pull-off Method (Surface Coatings & Tiles): Test block adhered to mortar, tile, or coating using specialized adhesive to measure tensile bond strength
. -
Post Anchoring Method: Anchoring hole filled with chemical anchoring adhesive and allowed to cure completely before applying tensile load
. -
After-loading and Pulling Out Method: Expansion spring and expansion rod inserted into pre-drilled concrete holes for direct pull-out strength evaluation
. -
Pull-off Method (Customized Anchors): Direct connection to customized mechanical or chemical anchors for pull-out retention testing
.
Why Choose MTM Precision in Malaysia?
09 Nov 2026