Lightweight Leakage Switch & RCD Tester in Malaysia: Exploring the Swevy SW-3880 Leakage Protection Tester
Lightweight Leakage Switch & RCD Tester in Malaysia: Exploring the Swevy SW-3880 Leakage Protection Tester
Multi-Current Testing for Single-Phase & Three-Phase Environments
-
Ten Selectable Leakage Current Steps: Covers 15, 30, 50, 75, 100, 150, 200, 250, 300, and 500 mAwith ±10% rdg + 2 dgt step current accuracy, enabling technicians to test high-sensitivity personal protection circuits as well as higher-rated industrial and distribution leakage switches.
-
Millisecond Trip-Time Measurement (0–999 ms): Evaluates actual leakage protector operating time from 0 to 999 ms with ±5% rdg ± 3 dgt display accuracy, providing clear quantitative verification rather than relying on subjective observation.
-
220V / 380V Test Line Compatibility: Supports 220V/380V leakage protector test circuits (with AC 220Vrated voltage across meter interfaces during testing), making it versatile for both residential/commercial single-phase installations and three-phase industrial distribution environments.
-
Manual & Automatic Test Modes: Offers both manual and automatic test modes so technicians can execute quick single checks or structured testing routines with minimal effort.
Compact Ergonomics, Display Clarity & Field Protection
-
128 x 64 Dot-Matrix LCD Screen: Features a 44 x 27 mm viewing area that presents test modes, current settings, trip times, and status alerts clearly on site.
-
Ultra-Light 290 g Handheld Build: Weighing only about 290 g including batteries (roughly 350 g total with packaging) and measuring a slim 170 x 75 x 30 mm, the SW-3880 fits effortlessly into a pocket, tool belt, or inspection pouch without adding fatigue.
-
Generous 1.5 m Test Lead Length: Supplied with a 1.5 m test lead to give operators comfortable reach and safer positioning when connecting to sockets or distribution panels.
-
Reliable Battery Management & Accuracy Assurance: Powered by four standard 1.5V LR6 AA alkaline batteries (DC 6V) with a low working current of 40 mA max. When battery voltage drops to 4.8V,a low-battery symbol alerts the user to replace the batteries while keeping measured readings accurate right up to that threshold.
-
High Insulation & Dielectric Strength: Built with insulation resistance of 100 MΩ or greater and AC 2 kV/rms dielectric withstand capability between the outer housing and screws, rated for -10°C to 40°Coperation (below 80% RH) and -10°C to 60°C storage (below 70% RH).
Where the Swevy SW-3880 Delivers Everyday Value in Malaysia
-
Commercial & Retail Fit-Outs: Verifying 30 mA and 100 mA leakage switches during handover inspections and periodic safety audits.
-
Industrial Plants & Workshops: Testing 220V/380V distribution circuits and higher-threshold leakage protectors up to 500 mA in a pocket-sized, 290 g meter.
-
Residential & Facility Preventive Maintenance: Conducting fast manual or automatic trip-time checks across living quarters, offices, schools, and public buildings.