Swevy Water Quality Meter in Malaysia: Compact TDS, Conductivity & Temperature Testing for Daily Water Checks
Swevy Water Quality Meter in Malaysia: Compact TDS, Conductivity & Temperature Testing for Daily Water Checks
Why Checking TDS, Conductivity & Temperature Together Matters
Slim, Lightweight & Practical for Everyday Portability
-
Three Measurement Parameters in One Pen: Measures TDS (0–9999 ppm, 1 ppm resolution), conductivity (0–9999 µS/cm, 1 µS/cm resolution), and temperature (0–50°C / 32–122°F, 0.1°Cresolution) with ±2% F.S. accuracy
. -
Switchable Units: Supports ppm for TDS, µS/cm for conductivity, and °C or °F for temperature so users can read values in their preferred unit
. -
Slim & Lightweight Form Factor: Measures 158 × 31 × 16 mm and weighs approximately 47g (excluding battery), making it easy to slip into a pocket, tool pouch, or testing kit
. -
ABS Body & Coin Cell Power: Constructed with an ABS housing and powered by one 3V CR2032 lithium button battery for compact, portable operation
. -
Defined Operating & Storage Conditions: Rated for operating and storage temperatures of 0–50°C at ≤85% RH (non-condensing)
.
Practical Applications Across Malaysian Homes, Farms & Workplaces
-
Home Filtration, RO & Drinking Water Systems: Perform quick routine checks on filtered water and monitor changes over time alongside filter maintenance schedules.
-
Hydroponics, Plant Care & Hobby Aquariums: Check water conductivity, TDS, and temperature quickly when preparing solutions or inspecting tanks.
-
Facility Maintenance & Utility Checks: Carry a lightweight testing pen during walk-throughs to check water points and temperature conditions on site.
-
Schools, Workshops & General Quality Checks: Provide students, technicians, and quality teams with a simple, portable tool for routine water and solution checks.
Good Habits for Accurate, Reliable Pen Meter Readings
-
Rinse & Blot Between Samples: Rinse the sensing end cleanly with suitable water and blot gently with a soft, lint-free tissue between tests so residue from one sample does not carry over into the next.
-
Allow Brief Stabilization in the Sample: Hold the sensor steadily in the liquid without trapped air bubbles and wait a moment for the reading to settle before recording your value.
-
Respect Temperature & Humidity Limits: Operate and store the meter within 0–50°C and ≤85% RH (non-condensing) as specified
. -
Keep the Battery Compartment Clean & Dry: Replace the 3V CR2032 battery when display clarity fades, and keep the instrument dry and protected when stored
.
Source Your Swevy Water Quality Meter from MTM Precision in Malaysia
22 Nov 2026