Elitech Inframate S Infrared Refrigerant Leak Detector Supplier Malaysia

For HVAC technicians, refrigeration contractors and automotive air-conditioning workshops, locating a small refrigerant leak can be difficult when the source is hidden around pipe joints, valves, coils or service connections. The Elitech Inframate S Infrared Refrigerant Leak Detector is designed to help professionals locate supported refrigerant leaks during inspection and troubleshooting work.

 

MTM Precision currently has one unit of Elitech Inframate S ready stock in Malaysia, subject to prior sale and final stock confirmation.

 

What Is the Elitech Inframate S?

 

The Elitech Inframate S is a handheld refrigerant leak detector that uses an infrared sensing principle. It is intended for professional air-conditioning, HVAC and refrigeration maintenance applications.

 

According to Elitech's published product information, the detector supports refrigerants within the following groups:

 

CFC refrigerants

 

HCFC refrigerants

 

HFC refrigerants

 

HFO-1234yf

 

Compatibility should always be checked against the exact refrigerant used by the equipment. Technicians should not assume that every gas or newly introduced refrigerant is supported simply because the instrument is described as a refrigerant leak detector.

 

Why Use an Infrared Refrigerant Leak Detector?

 

Refrigerant can escape through a very small opening around a fitting, valve, coil or connection. The leak may not be visible, and signs such as reduced cooling performance do not automatically reveal its exact location.

 

An infrared refrigerant leak detector helps the technician search around suspected areas and identify where supported refrigerant gas is present near the probe.

 

Compared with basic leak detectors using other sensing methods, an infrared model may be considered by technicians who value:

 

Longer sensor service life

 

Resistance to exposure to high refrigerant concentrations

 

Fast response during leak searching

 

Reduced sensor replacement requirements

 

Clear visual and audible indications

 

Suitability for regular professional inspection

 

The detector is a locating instrument. It does not replace pressure measurement, system diagnosis, safe isolation, pressure testing or another appropriate leak-verification method.

 

Published Sensitivity Levels

 

Elitech publishes three sensitivity levels for the Inframate S:

 

High sensitivity: 0.1 oz/year, below 4 g/year

 

Medium sensitivity: 0.25 oz/year, approximately 7 g/year

 

Low sensitivity: 0.50 oz/year, approximately 14 g/year

 

Higher sensitivity may help when searching for a small leak. However, it can also make the detector more responsive to refrigerant already dispersed in the surrounding air.

 

The appropriate sensitivity depends on the application, suspected leak size, ventilation, background refrigerant concentration and inspection environment.

 

Fast Response for Refrigerant Leak Searching

 

Elitech publishes a response time of less than one second for the Inframate S under the specified conditions.

 

A fast response can help technicians move the probe around suspected components and observe changes in the detector's indication. However, moving too quickly may cause a small leak point to be missed.

 

Technicians should follow the product manual and applicable HVAC servicing procedures rather than relying only on the response-time figure.

 

Infrared Sensor Designed for Professional Use

 

High concentrations of refrigerant may affect some traditional sensing elements. Elitech states that the infrared sensor used in the Inframate S is designed not to be damaged by high refrigerant concentrations.

 

This can be useful for technicians working around:

 

Air-conditioning service connections

 

Commercial refrigeration equipment

 

Cold-room systems

 

Compressor areas

 

Refrigerant charging locations

 

Automotive air-conditioning systems

 

This feature does not mean that the instrument can be exposed without limitation. Proper handling, ventilation, filter maintenance and operating procedures remain important.

 

Colour Display and Flexible Probe

 

The Elitech Inframate S includes a colour TFT display designed to present detection information clearly.

 

Its flexible probe allows the technician to reach around components and into areas that may be difficult to inspect directly. Elitech publishes a probe length of approximately 445 mm.

 

The probe may assist when checking areas such as:

 

Evaporator coils

 

Condenser coils

 

Refrigerant pipe fittings

 

Service valves

 

Flare connections

 

Brazed joints

 

Compressor connections

 

Charging ports

 

Components located inside equipment cabinets

 

The probe should not be forced into moving machinery, live electrical sections or locations where it may be damaged.

 

Automatic Calibration and Warm-Up

 

Elitech states that the Inframate S provides automatic calibration and has a published warm-up time of approximately 30 seconds.

 

The detector should be allowed to complete its preparation process before leak searching begins. Starting an inspection before the instrument is ready may result in unstable or misleading indications.

 

The surrounding air may already contain refrigerant, especially after charging, recovery or previous servicing work. Where practical, calibration and initial preparation should be performed in a suitable environment according to the manufacturer's instructions.

 

Typical Applications in Malaysia

 

The Elitech Inframate S refrigerant leak detector may be considered for a range of professional applications in Malaysia.

 

Residential Air-Conditioning Service

 

Air-conditioning technicians can use a compatible refrigerant leak detector when checking suspected leakage around split-unit connections, valves, coils and refrigerant piping.

 

Reduced cooling performance alone does not prove that refrigerant is leaking. The complete system should still be inspected by a qualified technician.

 

Commercial HVAC Maintenance

 

Facility maintenance teams and HVAC contractors may need to inspect refrigerant systems serving offices, retail premises, hotels and commercial buildings.

 

A handheld detector can support targeted checking around accessible components during troubleshooting or preventive maintenance.

 

Cold Rooms and Commercial Refrigeration

 

Cold-room contractors and refrigeration technicians may use the Inframate S to search for supported refrigerant leaks around equipment such as condensing units, evaporators, pipe joints and service connections.

 

The detector does not determine whether the system contains the correct refrigerant charge.

 

Supermarket Refrigeration

 

Display chillers, freezers and refrigeration systems may contain multiple joints and components. A portable detector can help technicians narrow down a suspected leak area before deciding on the appropriate verification and repair work.

 

Automotive Air-Conditioning

 

The Inframate S may be considered for compatible automotive air-conditioning refrigerants, including HFO-1234yf as identified in Elitech's published information.

 

The vehicle's refrigerant label and the detector's current compatibility information should be checked before use.

 

Common Areas Where Refrigerant Leaks May Occur

 

A refrigerant leak may develop around:

 

Flare joints

 

Brazed joints

 

Service valves

 

Schrader valves

 

Charging ports

 

Compressor connections

 

Evaporator coils

 

Condenser coils

 

Refrigerant pipe fittings

 

Components affected by vibration

 

Corroded sections

 

Damaged seals or connections

 

An alarm near one of these areas does not automatically confirm the exact point of failure. The technician should narrow down the location and verify the suspected leak before beginning repair work.

 

Factors That Can Affect Refrigerant Leak Detection

 

Detection results can be influenced by several conditions.

 

Air Movement

 

Strong ventilation, fans or outdoor wind may disperse refrigerant and make the source more difficult to locate.

 

Background Refrigerant

 

Recently released refrigerant may remain in the surrounding air and cause indications away from the actual leak point.

 

Probe Movement

 

Moving the probe too quickly or holding it too far from the suspected component may reduce the chance of locating a small leak.

 

Contamination

 

Oil, dirt, moisture and chemicals around the work area may complicate the inspection process.

 

Incorrect Refrigerant Assumption

 

The detector must be compatible with the refrigerant used by the system. The equipment label and service information should be checked before testing.

 

What the Inframate S Cannot Do

 

The Elitech Inframate S is designed to locate supported refrigerant gas near its probe. It cannot independently:

 

Measure refrigerant pressure

 

Confirm the total refrigerant charge

 

Diagnose every HVAC fault

 

Determine cooling capacity

 

Confirm that a system is safe to operate

 

Replace pressure testing

 

Identify every mechanical defect

 

Decide whether a component should be repaired or replaced

 

Detect gases outside the supported refrigerant groups

 

Provide a complete system condition assessment

 

A leak detector should be used as part of a proper diagnostic process rather than as the only instrument used during HVAC troubleshooting.

 

Elitech Inframate S vs Inframate S MAX

 

The Elitech Inframate S and Elitech Inframate S MAX are different models.

 

Elitech publishes a maximum sensitivity below 4 g/year for the standard Inframate S. The manufacturer publishes a maximum sensitivity of 1 g/year for the Inframate S MAX and separately identifies the MAX model as A2L compatible.

 

Customers should verify the complete model name before ordering. Specifications published for the Inframate S MAX must not automatically be applied to the standard Inframate S.

 

Who Should Consider the Elitech Inframate S?

 

The Inframate S may be suitable for:

 

Air-conditioning service technicians

 

HVAC contractors

 

Refrigeration contractors

 

Cold-room maintenance companies

 

Facility maintenance departments

 

Automotive air-conditioning workshops

 

Commercial refrigeration technicians

 

Technical service teams that regularly inspect refrigerant systems

 

Customers who require only occasional basic checking may compare the Inframate S with lower-cost heated diode models. Professionals who perform regular leak inspections may place greater value on the infrared sensing method and longer sensor-service potential.

 

What to Check Before Purchasing

 

Before requesting a quotation, prepare the following information:

 

Refrigerant type used by the equipment

 

HVAC, refrigeration or automotive application

 

Expected frequency of use

 

Required sensitivity

 

Indoor, outdoor or workshop environment

 

Need for A2L compatibility

 

Preference for infrared or heated diode sensing

 

Availability of local product support

 

Required delivery location

 

Current stock availability

 

Providing this information helps the supplier recommend a more suitable refrigerant leak detector without relying only on the model name.

 

Elitech Inframate S Ready Stock Malaysia

 

MTM Precision currently has one Elitech Inframate S available from ready stock, subject to prior sale.

 

Customers in Selangor and Kuala Lumpur may contact our Puchong showroom to confirm availability before visiting. Delivery enquiries from Johor, Penang and other parts of Malaysia are also welcome.

 

Stock availability should always be confirmed before placing an order or arranging collection.

 

Frequently Asked Questions

 

1. What is the Elitech Inframate S?

 

The Elitech Inframate S is a handheld infrared refrigerant leak detector for professional HVAC, refrigeration and compatible automotive air-conditioning applications.

 

2. Which refrigerant groups can it detect?

 

Elitech identifies CFC, HCFC, HFC and HFO-1234yf among the supported refrigerant groups. The exact refrigerant should still be verified before use.

 

3. What is its maximum published sensitivity?

 

The manufacturer publishes a high sensitivity level of 0.1 oz/year, below 4 g/year.

 

4. Does it provide different sensitivity settings?

 

Yes. Elitech publishes high, medium and low sensitivity levels for the Inframate S.

 

5. How quickly does it respond?

 

Elitech publishes a response time of less than one second under the specified conditions.

 

6. How long does it take to warm up?

 

The published warm-up time is approximately 30 seconds.

 

7. Does the Inframate S use an infrared sensor?

 

Yes. It uses an infrared sensing principle for supported refrigerant leak detection.

 

8. Can it be used for cold-room maintenance?

 

It may be considered for cold-room and commercial refrigeration inspection when the system uses a compatible refrigerant.

 

9. Can it be used for automotive air-conditioning?

 

It may be considered for compatible automotive air-conditioning systems. Elitech specifically lists HFO-1234yf in its published refrigerant information.

 

10. Can the Inframate S measure refrigerant pressure?

 

No. A refrigerant leak detector does not replace a manifold gauge or another suitable pressure-measurement instrument.

 

11. Does an alarm confirm the exact leak point?

 

An alarm indicates that supported refrigerant is present near the probe. The suspected area should be narrowed down and verified before repair.

 

12. Is the Inframate S the same as the Inframate S MAX?

 

No. They are separate models with different published specifications.

 

13. Is the standard Inframate S identified as A2L compatible?

 

Elitech separately identifies the Inframate S MAX as A2L compatible. Customers requiring A2L compatibility should verify the exact model and current manufacturer documentation before purchasing.

 

14. Is the Elitech Inframate S available in Malaysia?

 

MTM Precision currently has one unit available, subject to prior sale and final stock confirmation.

 

15. Where can I request a quotation?

 

Contact MTM Precision with the refrigerant type, equipment application and delivery location. Our team can confirm current stock and quotation details.

 

Internal Linking

 

Infrared vs Heated Diode Refrigerant Leak Detector Malaysia

 

How to Choose a Refrigerant Leak Detector for HVAC Work Malaysia

 

Elitech Inframate S vs Inframate S MAX Malaysia

 

Refrigerant Leak Detection for Cold Room Maintenance Malaysia

 

HVAC Refrigerant Leak Troubleshooting Guide Malaysia

 

SEO Meta Title

 

Elitech Inframate S Refrigerant Leak Detector Supplier Malaysia

 

SEO Meta Description

 

Elitech Inframate S infrared refrigerant leak detector for HVAC, refrigeration, cold-room and automotive air-conditioning inspection. Contact MTM Precision in Puchong for ready-stock confirmation and quotation in Malaysia.

 

For product selection, stock confirmation or a quotation, WhatsApp MTM Precision with the refrigerant type, equipment application and delivery location.

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

Tel: +603-80807172

WhatsApp / Mobile: +6016-6607346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my


 

22 Nov 2026