Elitech Inframate S vs Inframate S MAX Refrigerant Leak Detector Malaysia

The Elitech Inframate S and Elitech Inframate S MAX are professional infrared refrigerant leak detectors, but they are not the same instrument. The S MAX offers higher published sensitivity and is specifically identified by Elitech as A2L compatible.

For Malaysian HVAC contractors, refrigeration technicians and automotive air-conditioning workshops, the correct choice depends on the refrigerants being serviced, required sensitivity, working environment and frequency of use.

MTM Precision currently has one unit of Elitech Inframate S ready stock in Malaysia, subject to prior sale and final stock confirmation. Inframate S MAX availability should be confirmed separately.

Quick Comparison

Elitech Inframate S

  • Infrared refrigerant sensing principle

  • Maximum published sensitivity below 4 g/year

  • Three published sensitivity levels

  • Published response time below one second

  • Approximately 30-second warm-up

  • Supports CFC, HCFC, HFC and HFO-1234yf refrigerant groups

  • Colour TFT indication

  • Published sensor life of approximately 10 years

  • Approximately eight hours of continuous operation

  • Flexible probe approximately 445 mm long

Elitech Inframate S MAX

  • Infrared refrigerant sensing principle

  • Maximum published sensitivity of 1 g/year

  • Published response time below one second

  • Approximately 30-second warm-up

  • Identified by Elitech as A2L compatible

  • Intended for halogen refrigerants according to Elitech

  • 2.8-inch colour display

  • Published sensor life of at least 10 years

  • More than eight hours of published operating time

  • Probe approximately 340 mm long

Specifications should be verified against the current Elitech documentation and the exact supplied configuration before ordering.

Main Difference: Maximum Sensitivity

The most important published difference is the maximum leak sensitivity.

Inframate S Sensitivity

Elitech publishes three sensitivity levels for the standard Inframate S:

  • High: 0.1 oz/year, below 4 g/year

  • Medium: 0.25 oz/year, approximately 7 g/year

  • Low: 0.50 oz/year, approximately 14 g/year

Inframate S MAX Sensitivity

Elitech publishes a maximum sensitivity of:

  • 0.03 oz/year, approximately 1 g/year

Based on these published figures, the Inframate S MAX is designed to detect a smaller leak rate under the manufacturer's specified test conditions.

This does not guarantee that every 1 g/year leak will be found in every work environment. Actual detection can be affected by airflow, background refrigerant, probe position, contamination and inspection technique.

Main Difference: A2L Compatibility

Elitech specifically identifies the Inframate S MAX as A2L compatible.

This distinction is important because A2L refrigerants have a lower flammability classification and require appropriate equipment selection, training and work procedures.

Customers working with an A2L refrigerant should not assume that the standard Inframate S has the same compatibility simply because both models use infrared technology.

Before purchasing a detector for A2L applications, verify:

  • Exact refrigerant

  • Exact detector model

  • Current Elitech documentation

  • Application requirements

  • Workplace safety procedures

  • Required servicing equipment

If confirmed A2L compatibility is a purchasing requirement, the Inframate S MAX is the clearer choice based on Elitech's published product information.

Refrigerant Coverage

Inframate S

Elitech publishes the following detectable refrigerant groups for the Inframate S:

  • CFC

  • HCFC

  • HFC

  • HFO-1234yf

Inframate S MAX

Elitech describes the Inframate S MAX as suitable for halogen refrigerants and specifically identifies the model as A2L compatible.

General category descriptions should not replace exact refrigerant verification. Customers should provide the refrigerant name when requesting a quotation.

Both Models Use Infrared Technology

Both the Inframate S and Inframate S MAX use an infrared sensing principle.

Infrared detectors are commonly considered by professional users who value:

  • Longer sensor service life

  • Resistance to high refrigerant concentrations

  • Stable long-term use

  • Reduced dependence on frequently replaced sensing elements

  • Fast response during systematic leak searching

Elitech publishes a sensor life of approximately 10 years for the Inframate S and at least 10 years for the Inframate S MAX.

Sensor life remains dependent on correct use, storage, maintenance and operating conditions.

Response Time

Elitech publishes a response time of less than one second for both models.

A fast response can help technicians search around accessible joints, valves, coils and service connections. It does not mean that the probe should be moved rapidly across the system.

A small leak may still be missed when:

  • The probe is too far from the source

  • The probe moves too quickly

  • Strong airflow carries refrigerant away

  • Background refrigerant affects the indication

  • The detector does not support the refrigerant

  • The leak is concealed

Inspection technique remains important regardless of the model selected.

Warm-Up Time

Elitech publishes a warm-up time of approximately 30 seconds for both the Inframate S and Inframate S MAX.

The detector should be allowed to complete its preparation before leak searching begins. An unstable indication during preparation should not be treated as a confirmed system leak.

The surrounding environment should also be considered. Refrigerant already present in the air may make localisation more difficult.

Display and Alarm Indication

The standard Inframate S provides audible and visual alarm indications with a TFT display.

The Inframate S MAX is specified with sound and display alarms and a 2.8-inch colour display.

The display helps the technician observe changes in detector response, but neither model independently provides:

  • The exact physical size of the leak opening

  • Total refrigerant loss

  • Remaining system charge

  • System operating pressure

  • Required repair method

  • Complete system diagnosis

A detector indication should be used to narrow down the suspected area before verification.

Probe Length

Elitech publishes different probe lengths for the two models:

  • Inframate S: approximately 445 mm

  • Inframate S MAX: approximately 340 mm

A longer probe may be helpful when reaching around coils, pipework or components inside an accessible equipment cabinet.

A shorter probe may feel easier to control in certain workshop applications. The better configuration depends on the equipment layout and technician preference.

The probe must not be placed into live electrical areas, moving fans or rotating machinery.

Operating Time

Elitech publishes approximately eight hours of continuous operation for the standard Inframate S.

The published operating time for the Inframate S MAX is more than eight hours.

Actual operating time can vary with:

  • Battery condition

  • Charging history

  • Display use

  • Operating environment

  • Instrument age

  • Storage condition

Technicians should check battery condition before attending a field service location.

Which Model Is Better for Standard HVAC Work?

The Elitech Inframate S may be sufficient when:

  • The required refrigerant is supported

  • Maximum sensitivity below 4 g/year meets the application

  • A2L compatibility is not the deciding requirement

  • The user wants a professional infrared detector

  • A longer flexible probe is useful

  • Ready stock availability is important

  • The detector will be used for conventional HVAC and refrigeration work

For many routine air-conditioning and commercial refrigeration inspections, the standard Inframate S may provide the required balance of sensitivity, sensor life and professional usability.

Which Model Is Better for Smaller Leak Detection?

The Elitech Inframate S MAX may be preferred when:

  • A published sensitivity of 1 g/year is required

  • Smaller leak localisation is a priority

  • A2L compatibility is required and verified

  • The user wants the newer higher-sensitivity model

  • The application justifies the upgraded specification

  • Exact model availability can be confirmed

The S MAX should not be selected only because its maximum sensitivity number is lower. The refrigerant, working environment and inspection requirements must still match the detector.

Which Model Is Better for A2L Refrigerants?

Based on Elitech's published information, the Inframate S MAX is the appropriate model to evaluate when A2L compatibility is required.

The standard Inframate S product information includes CFC, HCFC, HFC and HFO-1234yf refrigerant groups, but Elitech separately highlights A2L compatibility for the S MAX.

Customers should not transfer the S MAX compatibility statement to the standard S without written manufacturer confirmation.

Which Model Is Better for Automotive Air-Conditioning?

The correct model depends on the vehicle refrigerant and workshop requirements.

The standard Inframate S includes HFO-1234yf in Elitech's published detectable-gas information. The S MAX provides higher published sensitivity and is identified as A2L compatible.

Before choosing, the workshop should verify:

  • Vehicle refrigerant label

  • Exact refrigerant

  • Required sensitivity

  • Current manufacturer compatibility

  • Applicable automotive servicing requirements

  • Frequency of use

Neither model should be assumed suitable for every vehicle or every gas.

Which Model Is Better for Cold Rooms?

For conventional cold-room systems using a supported refrigerant, the standard Inframate S may be suitable when its published sensitivity meets the inspection requirement.

The S MAX may be considered when:

  • Higher sensitivity is required

  • Smaller leaks are a concern

  • The refrigerant requires verified A2L compatibility

  • The contractor handles newer system types

  • The upgraded model fits the purchasing budget

Cold-room temperature problems may also involve airflow, dirty heat exchangers, controls, insulation or mechanical faults. A refrigerant detector does not diagnose all possible causes.

Does Higher Sensitivity Always Mean Better Results?

No.

Higher sensitivity can help locate smaller refrigerant concentrations, but it can also make the detector more responsive to refrigerant already present in the surrounding air.

Results still depend on:

  • Refrigerant compatibility

  • Background refrigerant

  • Airflow

  • Probe position

  • Probe movement

  • Instrument condition

  • Filter condition

  • Technician technique

The most sensitive detector is not automatically the most suitable detector for every application.

Price vs Application

MTM Precision does not publish the product price in this article because quotations may depend on model, stock status and delivery requirements.

Customers should compare the two models according to:

  • Refrigerant type

  • Required sensitivity

  • A2L compatibility

  • Frequency of use

  • Probe preference

  • Application environment

  • Long-term sensor considerations

  • Current availability

  • Budget

Buying the higher model without a clear application requirement may increase cost without providing a meaningful advantage. Buying the lower model without checking refrigerant compatibility may result in an unsuitable instrument.

Model Selection Summary

Choose the Elitech Inframate S when:

  • Below 4 g/year published sensitivity is sufficient

  • The supported refrigerant groups match the application

  • A longer published probe length is preferred

  • A professional infrared detector is required

  • Ready stock availability is important

Choose the Elitech Inframate S MAX when:

  • 1 g/year maximum published sensitivity is required

  • Elitech-identified A2L compatibility is required

  • The application involves smaller leak localisation

  • The upgraded specification is justified

  • Availability has been confirmed

Elitech Inframate S Ready Stock Malaysia

MTM Precision currently has one unit of Elitech Inframate S ready stock, subject to prior sale and final confirmation.

Inframate S MAX stock should be checked separately.

Customers in Selangor and Kuala Lumpur may arrange to visit our Puchong showroom after confirming availability. Delivery enquiries from Johor, Penang and other parts of Malaysia are welcome.

Please provide the exact refrigerant, application and preferred model when requesting a quotation.

Frequently Asked Questions

1. Are the Inframate S and Inframate S MAX the same detector?

No. They are separate models with different sensitivity, probe and compatibility information.

2. Which model has the higher published sensitivity?

The Inframate S MAX. Elitech publishes a maximum sensitivity of 1 g/year, compared with below 4 g/year for the standard S.

3. Which model is identified as A2L compatible?

Elitech specifically identifies the Inframate S MAX as A2L compatible.

4. Does the standard Inframate S support HFO-1234yf?

Elitech includes HFO-1234yf in the standard Inframate S detectable-gas information.

5. Do both models use infrared technology?

Yes. Both are infrared refrigerant leak detectors.

6. What is the published response time?

Elitech publishes a response time below one second for both models.

7. What is the published warm-up time?

Approximately 30 seconds for both models.

8. Which model has the longer published probe?

The standard Inframate S, with a published probe length of approximately 445 mm.

9. Which model is better for small leaks?

The Inframate S MAX has the higher published sensitivity, but actual detection still depends on the application and inspection conditions.

10. Is the S MAX automatically better for every technician?

No. The standard Inframate S may be sufficient when its compatibility and sensitivity match the intended work.

11. Can either model measure refrigerant pressure?

No. A suitable pressure-measurement instrument is required.

12. Can either model calculate the remaining refrigerant charge?

No. They are designed to locate supported refrigerant near the probe.

13. Is the standard Inframate S available in Malaysia?

MTM Precision currently has one unit available, subject to prior sale and final stock confirmation.

14. Is the Inframate S MAX ready stock?

Availability should be confirmed separately with MTM Precision.

15. What information should I provide for model selection?

Provide the exact refrigerant, HVAC or refrigeration application, required sensitivity, A2L requirement and delivery location.

Internal Linking

  • Elitech Inframate S Infrared Refrigerant Leak Detector Supplier Malaysia

  • Infrared vs Heated Diode Refrigerant Leak Detector Malaysia

  • How to Choose a Refrigerant Leak Detector for HVAC Work Malaysia

  • Refrigerant Leak Detection for Cold Room Maintenance Malaysia

  • Air Conditioner Not Cooling and Refrigerant Leak Cannot Be Found Malaysia

SEO Meta Title

Elitech Inframate S vs Inframate S MAX Malaysia

SEO Meta Description

Compare Elitech Inframate S and Inframate S MAX infrared refrigerant leak detectors. Review sensitivity, A2L compatibility, probe length, applications and Malaysia availability.

For help choosing between the Inframate S and Inframate S MAX, WhatsApp MTM Precision with the exact refrigerant, application and required sensitivity.

MTM Precision Sdn Bhd

Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: +603-80807172
WhatsApp / Mobile: +6016-6607346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my

23 Nov 2026