The Elitech Inframate S is an infrared refrigerant leak detector designed for professional HVAC, refrigeration and compatible automotive air-conditioning applications.
Before purchasing or using the detector, customers should understand its refrigerant compatibility, sensitivity, intended applications and practical limitations.
MTM Precision currently has one unit of Elitech Inframate S ready stock in Malaysia, subject to prior sale and final stock confirmation.
Elitech Inframate S Overview
The Inframate S uses infrared absorption spectroscopy to detect supported refrigerants near its probe.
According to Elitech's published information, the detector offers:
Infrared refrigerant sensing
Three sensitivity levels
Maximum published sensitivity below 4 g/year
Published response time below one second
Approximately 30-second warm-up
Automatic calibration
Audible and visual indication
Colour TFT display
Approximately eight hours of continuous operation
Flexible probe approximately 445 mm long
Published sensor life of approximately 10 years
Published specifications apply under the manufacturer's stated conditions. Actual detection depends on the refrigerant, environment, airflow, probe position and instrument condition.
Who Is the Inframate S Designed For?
The detector may be considered by:
Air-conditioning technicians
HVAC contractors
Refrigeration contractors
Cold-room technicians
Facility maintenance teams
Commercial building maintenance departments
Compatible automotive air-conditioning workshops
Technical training organisations
The user should understand the equipment being inspected and follow applicable refrigerant-handling and safety procedures.
Supported Refrigerant Groups
Elitech publishes support for refrigerants within the following groups:
CFC
HCFC
HFC
HFO-1234yf
The exact refrigerant should be confirmed from the equipment label, compressor information, vehicle label or system documentation.
A description such as "Freon detector" does not confirm compatibility with every refrigerant or gas.
Published Sensitivity
The Inframate S has three published sensitivity levels:
High: 0.1 oz/year, below 4 g/year
Medium: 0.25 oz/year, approximately 7 g/year
Low: 0.50 oz/year, approximately 14 g/year
Higher sensitivity may help with smaller refrigerant concentrations. It may also cause a broader response when refrigerant is already present in the surrounding air.
Sensitivity should not be treated as a guarantee that every leak of that rate will be found in every working environment.
Typical Applications
The Inframate S may support compatible refrigerant leak searching for:
Residential split air conditioners
Commercial HVAC systems
Cold rooms
Supermarket refrigeration
Restaurant chillers and freezers
Factory cooling equipment
Warehouse refrigeration
Facility maintenance
Compatible automotive air-conditioning systems
The detector is intended to help locate refrigerant. It is not a complete HVAC or refrigeration diagnostic instrument.
Common Leak Areas
Depending on the system design, possible leak areas may include:
Flare joints
Brazed connections
Service valves
Schrader valves
Charging ports
Compressor connections
Evaporator coils
Condenser coils
Filter-drier connections
Pipe fittings
Corroded tubing
Components affected by vibration
Previously repaired sections
A detector response near a component does not independently prove that the component has failed.
What Can Affect Detection?
Detection can be influenced by:
Strong airflow
Background refrigerant
Unsupported refrigerant
Probe position
Probe movement
Leak accessibility
Filter condition
Battery condition
Instrument preparation
Moisture or contamination
Operating environment
A non-response does not automatically prove that the complete system is free from leaks.
Airflow and Background Refrigerant
Airflow may come from:
Indoor-unit fan
Condenser fan
Mechanical ventilation
Workshop fan
Exhaust system
Outdoor wind
Open doors or windows
Airflow can move refrigerant away from its original source.
Recent charging, recovery or hose disconnection may also leave refrigerant in the surrounding air. This can cause the detector to respond across a broad area rather than at one specific component.
What Does an Alarm Mean?
An alarm indicates that supported refrigerant may be present near the probe.
It does not independently confirm:
Exact leak-opening size
Total refrigerant loss
Remaining refrigerant charge
System pressure
Required repair
Compressor condition
Cooling capacity
Complete system safety
The suspected location should be narrowed down and verified using an appropriate method.
What the Inframate S Cannot Measure
The Inframate S cannot independently:
Measure refrigerant pressure
Calculate refrigerant charge
Identify an unknown gas
Measure airflow
Diagnose electrical faults
Assess compressor output
Measure cooling capacity
Test thermostat accuracy
Determine system energy efficiency
Decide whether a component requires replacement
Additional instruments and professional assessment may be required.
Inframate S vs Inframate S MAX
The standard Inframate S and Inframate S MAX are different models.
Elitech publishes:
Maximum sensitivity below 4 g/year for Inframate S
Maximum sensitivity of 1 g/year for Inframate S MAX
Specific A2L compatibility for Inframate S MAX
Customers requiring specifically documented A2L compatibility should evaluate the Inframate S MAX and verify the current manufacturer documentation.
Do not apply S MAX specifications automatically to the standard Inframate S.
Infrared vs Heated Diode
An infrared detector may be considered when:
The instrument will be used regularly
Longer sensor life is important
High refrigerant exposure may occur
Reduced sensing-element replacement is preferred
Long-term operating cost matters
A heated diode detector may remain suitable when:
Usage is occasional
Initial purchasing budget is limited
Replacement sensing elements are acceptable
The selected model supports the refrigerant
The correct choice depends on the application rather than sensing technology alone.
Maintenance Considerations
The detector should be protected from:
Oil
Water
Condensation
Excessive dust
Chemical contamination
Physical impact
Probe crushing
Moving machinery
Live electrical parts
Unsuitable storage conditions
Filter attention, cleaning, battery care and functional checking should follow the current Elitech instructions.
Do not use an unverified chemical, test gas or dismantling procedure.
Ready Stock and Malaysia Enquiries
MTM Precision currently has one Elitech Inframate S available from ready stock, subject to prior sale and final confirmation.
Customers in Selangor and Kuala Lumpur may confirm availability before visiting our Puchong showroom.
Delivery enquiries from Johor, Penang and other parts of Malaysia are welcome.
Frequently Asked Questions
1. What is the Elitech Inframate S?
It is a handheld infrared refrigerant leak detector for professional HVAC, refrigeration and compatible automotive air-conditioning applications.
2. Which refrigerant groups does it support?
Elitech publishes support for CFC, HCFC, HFC and HFO-1234yf refrigerant groups.
3. Can it detect every refrigerant?
No. The exact refrigerant must be checked against the current manufacturer information.
4. What is its highest published sensitivity?
Elitech publishes a high sensitivity level of 0.1 oz/year, below 4 g/year.
5. Does it have multiple sensitivity levels?
Yes. Elitech publishes high, medium and low sensitivity levels.
6. What is the published response time?
Elitech publishes a response time below one second under the stated conditions.
7. How long is the warm-up time?
The published warm-up time is approximately 30 seconds.
8. How long is the published sensor life?
Elitech publishes a sensor life of approximately 10 years under the stated conditions.
9. Can it be used for cold-room maintenance?
It may be considered when the cold-room system uses a supported refrigerant.
10. Can it be used for automotive air-conditioning?
It may support compatible automotive refrigerants. Elitech includes HFO-1234yf in its published information.
11. Can it identify an unknown refrigerant?
No. A refrigerant leak detector is not a refrigerant identifier.
12. Can it measure refrigerant pressure or charge?
No. Suitable pressure-measurement and servicing instruments are required.
13. Is the standard Inframate S identified as A2L compatible?
Elitech specifically identifies the Inframate S MAX as A2L compatible. Verify the exact model for A2L applications.
14. Is the Elitech Inframate S available in Malaysia?
MTM Precision currently has one unit available, subject to prior sale and final stock confirmation.
15. What information should I provide when requesting a quotation?
Provide the exact refrigerant, equipment application, required quantity and delivery or collection location.
Internal Linking
Elitech Inframate S Infrared Refrigerant Leak Detector Supplier Malaysia
Infrared vs Heated Diode Refrigerant Leak Detector Malaysia
How to Choose a Refrigerant Leak Detector for HVAC Work Malaysia
Refrigerant Leak Detection for Cold Room Maintenance Malaysia
Air Conditioner Not Cooling and Refrigerant Leak Cannot Be Found Malaysia
Elitech Inframate S vs Inframate S MAX Refrigerant Leak Detector Malaysia
HFO-1234yf Automotive Air Conditioning Leak Detection Malaysia
Commercial HVAC Refrigerant Leak Inspection and Preventive Maintenance Malaysia
Refrigerant Leak Detector Keeps Alarming or Does Not Respond Malaysia
How to Maintain an Infrared Refrigerant Leak Detector Malaysia
Elitech Inframate S Refrigerant Leak Detector for Johor HVAC Contractors Malaysia
Elitech Inframate S Refrigerant Leak Detector for Penang Industry Malaysia
Where to Buy Elitech Inframate S Refrigerant Leak Detector Malaysia
SEO Meta Title
Elitech Inframate S FAQ and Limitations Malaysia
SEO Meta Description
Elitech Inframate S FAQ covering refrigerant compatibility, sensitivity, cold-room and automotive applications, false alarms, maintenance, A2L limitations and Malaysia availability.
For product selection, stock confirmation or quotation, WhatsApp MTM Precision with the exact refrigerant, equipment application and delivery location.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
Tel: +603-80807172
WhatsApp / Mobile: +6016-6607346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
24 Nov 2026