Share:


CUSTOM Radiation thermometer IR-310H

Specifications

SKU: CUSTOM Radiation thermometer IR-310H

Product overview

[Measurement items] Temperature/non-contact550℃
[Measurement items] Temperature, K thermocoupleIncluded
[Measurement items] Temperature/wet bulb
[Measurement items] Temperature/dew point
[Function] Emissivity settingvariable
[Function] Hold
[Features] Equipped with backlight
[Function] Circular laser markerCircular laser marker
[Function] UV lightUV light
[Function] Temperature and humidity alertTemperature difference/condensation
[Features] PSC compatible
*1 Environmental humidity, built-in sensor
*2 Approximately 50 seconds (cannot be canceled)

A radiation thermometer with a UV light function that reacts to fluorescent agents for gas leak detection, ambient temperature, humidity, and condensation warning functions.

  • It can measure environmental temperature and humidity, dew point temperature, and wet bulb temperature. It warns you when there is a large difference in temperature between the object being measured and the environment, or when the object is prone to mold or condensation.
  • Emissivity: 0.10 to 1.00 variable (0.01 steps)
  • Circular laser marker function makes it easy to see the measurement point.
  • It uses a large color LCD screen with backlight.
  • Comes with a UV light (convenient for checking gas leaks using fluorescent agents, such as in car air conditioners)

"UV light" function that reacts with fluorescent agents to detect gas leaks, etc.

IR-310H product image*Image

The "circular laser marker" function makes it even easier to aim.

IR-310H product image*Image

Not only radiant temperature, but also ambient temperature and humidity are displayed at once.

IR-310H product image

Temperature measurement is also possible using a K-type thermocouple thermometer!

IR-310H K thermocouple compatible

The "Condensation Warning Mode" and "Temperature Difference Warning Mode" indicate the level of caution using the color of the LED at the top of the screen.

Part names

Main unit

IR-310H parts names
  • ①Environmental temperature and humidity sensor
  • ② Laser marker output unit
  • ③Sensor section
  • ④UV light
  • ⑤K thermocouple socket
  • ⑥ Measuring lever
  • ⑦Battery cover
  • ⑧UV light ON/OFF button
  • ⑨Mode switch button
  • 10. Laser ON/OFF button
  • ⑪Display section
  • ⑫Alarm display LED

Screen display example

IR-310H screen display example
  • ①SCAN/HOLD display
  • ②Environmental humidity icon/value display
  • ③Environment temperature icon/value display
  • ④Dew point temperature icon
  • ⑤Wet bulb temperature icon
  • ⑥Radiation temperature icon
  • ⑦Wet bulb temperature/radiant temperature value display
  • ⑧Dew point temperature/K thermocouple temperature value display
  • ⑨K thermocouple temperature icon
  • 10. Temperature units
  • ⑪Laser marker display
  • ⑫ Humidity units
  • ⑬Battery level display
  • ⑭Emissivity display
▲Back to top of page

specification

Electrical Performance

radiant temperature

Sensor Type Infrared sensor
Measurement range -50 to +550°C
resolution 0.1℃
Measurement accuracy
  • ±1.5% rdg or ±2°C, whichever is greater (0 to +550°C)
  • ±3°C (-50 to 0°C)
Emissivity Settings 0.10 to 1.00 (variable in 0.01 steps)
temperature sensor Infrared sensor
Measurement Area Size 13:1
Measurement wavelength 8 to 14 μm
Laser Class Class 2 *3
*3 JIS C6802 (2014)

K thermocouple temperature

Measurement range -50 to +850°C
resolution 0.1℃
Measurement accuracy ±1.5% rdg or ±1.5°C, whichever is greater

environmental temperature

Measurement range 0 to +50°C
resolution 0.1℃
Measurement accuracy
  • ±1.0°C (0 to +40°C)
  • ±2.0 ℃ (other than above)

environmental humidity

Measurement range 10 to 95% RH
resolution 1%RH
Measurement accuracy
  • ±3.0%RH (35 to 75%RH)
  • ±5.0 %RH (other than above)

Dew point temperature, wet bulb temperature

Measurement range -20 to +60°C
resolution 0.1℃
Measurement accuracy ±1.5 ℃ (+25 ℃, 40 to 80 %RH)

General specifications

sampling Approximately 2 times/second
Auto Power Off Approximately 50 seconds (cannot be canceled)
Operating temperature and humidity 0 to +50°C, 10 to 95% RH (no condensation)
Storage temperature and humidity -20 to +60°C, 80% RH or less (no condensation)
size Approx. W 46 × H 160 × D 105 mm
weight Approximately 235 g (including batteries)
power supply 9V battery x 1
battery life Approximately 8 hours (when using alkaline batteries)
accessories Instruction Manual, K-Type Thermocouple Sensor
proofreading Possible
JAN 4983621200188


 Inquiry - CUSTOM Radiation thermometer IR-310H